Premier 211-PT5A0-GJO+5581901, Three Phase Market Grade Revenue Meter for Small Commercial Applications, 5-20 Amp CT Connect, NMI 6
Three Phase Market/Revenue Grade Meter for small commercial applications
Usage
The meter is intended for measuring, monitoring three-phase electrical power network in residental, or small commercial applications for billing purposes. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Specification
Secure Part Number
Premier 211-PT5A0-GJO+5581901
Functions
Commercial Billing Meter with LCD Display
Nominal Measurement/Supply Range
3 x 2300/460VAC, 5-20 Amp 50Hz
Maximum Measurement Range
460VAC, 10/100 Amp 50Hz
4 Quadrant Measurement
Import/Export
Tariff Input
N/A
Accuracy
Class 1
Comms
N/A Optional Addon Module
Weight
2000g
Certification
CIEC/AS 62052-11, IEC/AS 62053-21, NMI M6-1
Factory Pack Qty
1
Safety
IP53
Enclosure Material
Engineering Plastic
Optional
RTC,Load Profile, RS485 Interface, Outputs
Operating Temperature
-40 →+80 °C
Datasheet
Datasheet
User Manual
IGC meters
MT860
MT830/831
ICG Meter Shortform
FGC1-KN31, 6 Amp Snap on Auxiliary Contacts for FGC1-K Series Miniature Contactors, 3 x NO, 1 x NC Aux Contacts
Features
Snap on
3 x NO, 1 x NC 6 Amp Contacts
20 grams
Datasheet
Auxiliary Contacts
FGC1-KN40 , 6 Amp Snap on Auxiliary Contacts for FGC1-K Series Miniature Contactors, 4 x NO Aux Contacts
Features
Snap on
4 x NO, 6 Amp Contacts
20 grams
Datasheet
Auxiliary Contacts
Infineon BSM100GB170DN2 IGBT Dual Module
Features
IGBT for Low Frequency Inverter
Pressure Contact Technology
Electrically insulated base plate
Wide Temperature Range
Medium Switching Speed
4000V Isolation
61mm Base Width
Applications
Frequency Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
Low Frequency Inverter
Drives
Specification
Infineon Part Number
BSM100GB170DN2
Vces
1700V
Transistor Configuration
Dual IGBT Module (Half Bridge)
Ic(nom) @ 80 Deg C
100 Amp
Package Size
W:61.4mm L:106.4mm D:30mm
V(isol)
4.0 kV
Vf @ 25 Deg C
2.3 - 2.8V
Tj(max)
150°C
Td(on) @ 25 Deg C
0.9uS
Td(off) @ 25 Deg C
1.2uS
I(ces) @ 25 Deg C
1mA
Rcc
0.65mOhm
Terminals
M6 Screw
Hole Centres
93 x 48mm(M6)
Gate Terminals
Spade (A 2.8 - 0.5mm)
R th(j-c)
0.26°C/W
R th(c-h)
N/A
Weight
400g
Mounting Torque
4 Nm (4 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
, Obsolete. See BSM100GB170DN2 for posible replacement part or Contact Us for Possible Replacement for alternative
FBT Y PVM 1200 RM, 1200VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
Specifications
Trent part number
FBT Y PVM 1200 RM
Nominal Voltage
1200VDC
No of Poles
3
Category IEC / EN / VDE
Type 2 (Class II)
Location of use
String Box, Inverter
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES NO/NC/COM
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC50539-11 (TUV Approved)
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
BA1-ND21-2, Indicator, 48x24mm, 5VDC, 4-20mA Input, 0-100.0 Display Range
3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Each unit needs just 40 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BA1-ND21-2
Control Output 1 (Heat)
N/A
Control Output 2 (Cool)
N/A
Input
4-20mA (0-100.0)
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
5VDC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BA1 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11