Search results for "��ũ��������Ʈ ���ּ�,COM Ŀ�´�Ƽ����Ʈ���� ���μ����Ǹ�ȭ �����ν� 19�� �����ּ� ��õ����Ʈ ��¥�θ�ȭ����"
-
F923 DC Series Current Transducer with Adjustable High and Low C/O Relay Alarm
F923 Series DC Current Transducer with Process Outputs & High and Low C/O Alarm Features Isolated measurement of DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-DC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$552.00 - $595.00
-
F921 DC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
F921 DC Series Current Transducer 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm Features Isolated measurement of DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-DC-XX-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 2500 Amp with External Sensor Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
F921 AC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
F921 Series AC Current Transducer with Process Outputs & High and Low C/O Alarm Features Isolated measurement of AC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-AC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 0-2500 Amp (with HAX 2500-S external Sensor) Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
HAX 3000-S, O/L Current Transducer, 3000 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output
Free Aus Post Shipping for $300 SpendLEM HAX 3000-S, O/L Current Transducer, 3000 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output Features Bandwidth DC to 25kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 2500 A in one package. Up to 5500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAX 3000-S Technology Open Loop Hall Effect Aperture 64 x 21mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 3000 Amp Measurement Range +/-6000 Amp Overload Rating +/-30000 At Output +/-4 V Isolation 4.4 kV Bandwidth DC-25 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 450g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition LEM Application Guide 2026