Premier 211-PT5A0-GJO+5581901, Three Phase Market Grade Revenue Meter for Small Commercial Applications, 5-20 Amp CT Connect, NMI 6
Three Phase Market/Revenue Grade Meter for small commercial applications
Usage
The meter is intended for measuring, monitoring three-phase electrical power network in residental, or small commercial applications for billing purposes. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Specification
Secure Part Number
Premier 211-PT5A0-GJO+5581901
Functions
Commercial Billing Meter with LCD Display
Nominal Measurement/Supply Range
3 x 2300/460VAC, 5-20 Amp 50Hz
Maximum Measurement Range
460VAC, 10/100 Amp 50Hz
4 Quadrant Measurement
Import/Export
Tariff Input
N/A
Accuracy
Class 1
Comms
N/A Optional Addon Module
Weight
2000g
Certification
CIEC/AS 62052-11, IEC/AS 62053-21, NMI M6-1
Factory Pack Qty
1
Safety
IP53
Enclosure Material
Engineering Plastic
Optional
RTC,Load Profile, RS485 Interface, Outputs
Operating Temperature
-40 →+80 °C
Datasheet
Datasheet
User Manual
IGC meters
MT860
MT830/831
ICG Meter Shortform
Gigavac GFP415A, DC Contactor Gigafuse, 400 Amp, 10kA, 1000VDC, 1500 Amp Trip Current, For FAST BATTERY DISCONNECT, Upright Mounted
Features
Isolated Fuse
Trip Ratings up to 2500 Amp
Panel Mount, Uprighted
IEC Standard 60269.1 AND 4
1000 V Voltage Rating
400 Amp Nominal Rating
Applications
Fast <3ms Clearance time
Short Circuit Protection
DC Contactor Fuse,
DC Motor Fuse
Battery Fuse
Specification
Trent Part Number
GFP415B
Fuse Type
DC Contactor / Batttery Disconnect Fuse
Nominal Voltage
1000VDC
Current Trip Point
1500 Amp
Nominal Current (DC)
400 Amp
Tested Breaking Capacity
10kA
Dimensions
103.5 x 91.27 x 61.33mm
Hole Centers
88.9mm
Mounting
Panel Mount, Upright
Operating Temperature Range
-40°C / 85°C
Termination
M8 x 1.25 Female
Unit Weight
790g
Factory Pack Qty
10
Datasheet
Product Datasheet
Gigavac GFP410A, DC Contactor Gigafuse, 400 Amp, 10kA, 1000VDC, 1000 Amp Trip Current, For FAST BATTERY DISCONNECT, Upright Mounted
Features
Isolated Fuse
Trip Ratings up to 2500 Amp
Panel Mount, Uprighted
IEC Standard 60269.1 AND 4
1000 V Voltage Rating
400 Amp Nominal Rating
Applications
Fast <3ms Clearance time
Short Circuit Protection
DC Contactor Fuse,
DC Motor Fuse
Battery Fuse
Specification
Trent Part Number
GFP410B
Fuse Type
DC Contactor / Batttery Disconnect Fuse
Nominal Voltage
1000VDC
Current Trip Point
1000 Amp
Nominal Current (DC)
400 Amp
Tested Breaking Capacity
10kA
Dimensions
103.5 x 91.27 x 61.33mm
Hole Centers
88.9mm
Mounting
Panel Mount, Upright
Operating Temperature Range
-40°C / 85°C
Termination
M8 x 1.25 Female
Unit Weight
790g
Factory Pack Qty
10
Datasheet
Product Datasheet
FBS LCD 24/4M, 24VDC Surge Protection Device for IT Systems, LPZ 0A-2 of higher, 10kA
Specifications
Telebahn part number
FBS LCD 24/4M
Nominal Voltage
24VDC
No of Poles
4
Category IEC / EN / VDE
Type 2
Location of use
Communication/Signal Lines
Protection modes
L1+/L1-, L2+/L2- , for
Additional Remote Contacts
NO
Protective element
MOV
No Fault/Fault Indication
N/A
Surge discharge rating
Per pole 10kA (8/20uS)10KA) Max, 20kA (8/20uS)2.5KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
120g
Standards
IEC 61643-21; EN 61643.21; GB 18802.21
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Gigavac GFP415B, DC Contactor Gigafuse, 400 Amp, 10kA, 1000VDC, 1500 Amp Trip Current, For FAST BATTERY DISCONNECT, Side Mounted
Features
Isolated Fuse
Trip Ratings up to 2500 Amp
Panel Mount, Side Mounteded
IEC Standard 60269.1 AND 4
1000 V Voltage Rating
400 Amp Nominal Rating
Applications
Fast <3ms Clearance time
Short Circuit Protection
DC Contactor Fuse,
DC Motor Fuse
Battery Fuse
Specification
Trent Part Number
GFP415B
Fuse Type
DC Contactor / Batttery Disconnect Fuse
Nominal Voltage
1000VDC
Current Trip Point
1500 Amp
Nominal Current (DC)
400 Amp
Tested Breaking Capacity
10kA
Dimensions
103.5 x 91.27 x 61.33mm
Hole Centers
88.9mm
Mounting
Panel Mount, Side Mounted
Operating Temperature Range
-40°C / 85°C
Termination
M8 x 1.25 Female
Unit Weight
790g
Factory Pack Qty
10
Datasheet
Product Datasheet
Gigavac GFP420A, DC Contactor Gigafuse, 400 Amp, 10kA, 1000VDC, 2000 Amp Trip Current, For FAST BATTERY DISCONNECT, Upright Mounted
Features
Isolated Fuse
Trip Ratings up to 2500 Amp
Panel Mount, Uprighted
IEC Standard 60269.1 AND 4
1000 V Voltage Rating
400 Amp Nominal Rating
Applications
Fast <3ms Clearance time
Short Circuit Protection
DC Contactor Fuse,
DC Motor Fuse
Battery Fuse
Specification
Trent Part Number
GFP420B
Fuse Type
DC Contactor / Batttery Disconnect Fuse
Nominal Voltage
1000VDC
Current Trip Point
2000 Amp
Nominal Current (DC)
400 Amp
Tested Breaking Capacity
10kA
Dimensions
103.5 x 91.27 x 61.33mm
Hole Centers
88.9mm
Mounting
Panel Mount, Upright
Operating Temperature Range
-40°C / 85°C
Termination
M8 x 1.25 Female
Unit Weight
790g
Factory Pack Qty
10
Datasheet
Product Datasheet
Gigavac GFP410B, DC Contactor Gigafuse, 400 Amp, 10kA, 1000VDC, 1000 Amp Trip Current, For FAST BATTERY DISCONNECT, Side Mounted
Features
Isolated Fuse
Trip Ratings up to 2500 Amp
Panel Mount, Side Mounteded
IEC Standard 60269.1 AND 4
1000 V Voltage Rating
400 Amp Nominal Rating
Applications
Fast <3ms Clearance time
Short Circuit Protection
DC Contactor Fuse,
DC Motor Fuse
Battery Fuse
Specification
Trent Part Number
GFP410B
Fuse Type
DC Contactor / Batttery Disconnect Fuse
Nominal Voltage
1000VDC
Current Trip Point
1000 Amp
Nominal Current (DC)
400 Amp
Tested Breaking Capacity
10kA
Dimensions
103.5 x 91.27 x 61.33mm
Hole Centers
88.9mm
Mounting
Panel Mount, Side Mounted
Operating Temperature Range
-40°C / 85°C
Termination
M8 x 1.25 Female
Unit Weight
790g
Factory Pack Qty
10
Datasheet
Product Datasheet
Gigavac GFP425A, DC Contactor Gigafuse, 400 Amp, 10kA, 1000VDC, 2500 Amp Trip Current, For FAST BATTERY DISCONNECT, Upright Mounted
Features
Isolated Fuse
Trip Ratings up to 2500 Amp
Panel Mount, Uprighted
IEC Standard 60269.1 AND 4
1000 V Voltage Rating
400 Amp Nominal Rating
Applications
Fast <3ms Clearance time
Short Circuit Protection
DC Contactor Fuse,
DC Motor Fuse
Battery Fuse
Specification
Trent Part Number
GFP425B
Fuse Type
DC Contactor / Batttery Disconnect Fuse
Nominal Voltage
1000VDC
Current Trip Point
2500 Amp
Nominal Current (DC)
400 Amp
Tested Breaking Capacity
10kA
Dimensions
103.5 x 91.27 x 61.33mm
Hole Centers
88.9mm
Mounting
Panel Mount, Upright, Side Mounted
Operating Temperature Range
-40°C / 85°C
Termination
M8 x 1.25 Female
Unit Weight
790g
Factory Pack Qty
10
Datasheet
Product Datasheet
Secure Sprint 350 3P4W 100 Amp RS232, Three Phase Revenue Grade Meter for Small Commercial Applications, 100 Amp Direct Connect, RS232 Comms, NMI NMI 14/2/84
Three Phase Revenue Grade Meter for small commercial applications
Usage
The meter is intended for measuring, monitoring three-phase electrical power network in residental, or small commercial applications for billing purposes. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Specification
Secure Part Number
Sprint 350 3P4W 100 Amp
Functions
Commercial Billing Meter with LCD Display
Nominal Measurement/Supply Range
3 x 100/240/400VAC, 10/100 Amp 50Hz
Maximum Measurement Range
460VAC, 10/100 Amp 50Hz
4 Quadrant Measurement
Import/Export
Tariff Input
N/A
Accuracy
Class 1
Comms
RS232 (Optional 4G available)
Weight
2000g
Certification
CIEC/AS 62052-11, IEC/AS 62053-21, NMI M6-1
Factory Pack Qty
1
Safety
IP53
Enclosure Material
Engineering Plastic
Optional
RTC,Load Profile, RS485 Interface, Outputs
Operating Temperature
-40 →+80 °C
Datasheet
Datasheet
IGC meters
MT860
MT830/831
ICG Meter Shortform
FBS RK 24 PA-II, Surge Protection Device For RS422/RS485 Devices 4 Pole, 24VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 7mm Wide Module
Application
IT Systems
Coarse and FIne Protection
Industrial Control System
Measurement System
Device Control
Specifications
Trent part number
FBS RK 24 PA-II
Nominal Voltage
24VDC
No of Poles
4
Category IEC / EN / VDE
LPZ 0 -2 or higher
Location of use
IT Communications Line/signals
Protection modes
TX+/TX-/RX+/RX-/GND
Additional Remote Contacts
N/A
Protective element
MOV
No Fault/Fault Indication
N/A
Surge discharge rating
Per pole 5kA (8/20uS)9KA) Max, 10kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
50g
Standards
IEC61643-21; GB 18802.21 ; YD/T 1542
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
FBT Y PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
Specifications
Trent part number
FBT Y PVM 1000 RM
Nominal Voltage
1000VDC
No of Poles
3
Category IEC / EN / VDE
Type 2 (Class II)
Location of use
String Box, Inverter
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES NO/NC/COM
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC614643-11:GB/T 18802.11: YD/T 1235.1, CE
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester