BLR-Q(U)06R MB(3ACM06R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ
Single CT Sensing
32nd Harmonic Measurement
Isolated Switching of Power Factor Correction Contactors
Cos ϕ Setting 0.9 to 0.9 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 6 steps
Measurement System - Automatic/Manual
50-530VAC Measurement
100-132V / 207-253VAC (L-N) Aux Supply
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
RS485 Modbus RTU
Specification
Beluk Part Number
BLR-Q(U)06R MB/ 3ACM06R-BEL-O-QMB
Function
Reactive Power Correction & Power Quality Analyser
Nominal Voltage (Un)
50-530VAC Line to Line
Supply Voltage
100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A
Relay Rating
250VAC/5Amp
Static Output Rating (T Models)
8-48VDC / 100mA
Internal 2MB Logger
Optional
3 x CT Measurement
Optional
Switch Delay Time
1s - 1200s User Adjustable
Alarm
1 x Relay as above
Temperature/Fan/THD Alarm
1 x Relay as above
Re-connection Delay Time
50 - 1200s User Adjustable
Desired Power Factor
0.90 IND - 0.90 CAP
Number of Output Relays
6
Smallest Capacitor Current
10mA
CT Input Range
15mA - 6 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 Modbus RTU Included
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
User Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Quick Start Guide(Blog)
Crydom PMP2450WP, Phase/Burst control, 240VAC, 50 Amp, Selectable 0-5V,0-10V,4-20mA input, w/Overvoltage Protection
Features
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
PMP2450WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
50 Amp (rms)
Surge Capability
716Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
170-280VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
160g
Factory Pack Qty
20
Datasheet
Product Datasheet
PMP24 Installation/Wiring Guide
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
RS1A
Contact Us for Possible Replacement
Heatsink
SSR and Heatsink Assemblies
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Crydom CC4850W3VH, Dual Solid State Relay, 50 Amp x 2, 4-32VDC Control, 600VAC Output, 4 Screw Terminal, A Channel Left, B Channel Right, w/ IP20 Plastic Cover
Features
Ratings from 2 x 25A to 2 x 50 Amp @ 48-600VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CC4850W3VH
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
15-32VDC
Load Current
2 x 50 Amp (rms)
Surge Capability
750 Amp (peak)
Special Feature
IP20, LED Status Indicator, Dual SSR, 1200V Transient Withstand
Mounting Style
Panel Mount
Load Voltage Range
48-600VAC
EMC Compliant
Level 3
Termination Style
Screw and Molex 39500-0004
Unit Weight
89g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
H12D4840DE
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom PMP4850WP, Phase/Burst control, 240VAC, 50 Amp, Selectable 0-5V,0-10V,4-20mA Input, w/Overvoltage Protection
Features
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
PMP4850WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
50 Amp (rms)
Surge Capability
716Amp (peak)
Special Feature
Proportional Controller + SSR, Overvoltage protection
Mounting Style
Panel Mount
Load Voltage Range
345-530VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
160g
Factory Pack Qty
20
Datasheet
Product Datasheet
PMP24 Installation/Wiring Guide
Equivalent
Crydom PMP2425W or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
RCS-3605-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 12 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils):
The RCS-3605 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-3605 comes with 5 Amp integrator..
Included is an 36 inch circumference rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-3605-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Output Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
3500g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
LEM ART-B22-D70-SP3 + AI-PMUL - 3Pcs, 3 Phase Rogowski Coils & Universal Multi Range Integrator with Signal Conditioner
The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V.
2 selectable instantaneous output signals: 225 mV, 333 mV.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Included Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
ART-B22-D70-SP3 + AI-PMUL - 3Pcs
Function
3 Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon)
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
AI-PMUL Datasheet
ART Series Datasheet
Applicaton Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Crydom HS501DR + RPC2440, Single Phase Proportional Phase Controller with Heatsink, for 500K - 1M POT input, 90-280VAC, 10 Amps
Features
Potentiometer Proportional Phase Control Input
Ratings from 25A to 40 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + RPC2440
Switching Type
Phase Angle (Random Crossing)
ROHS/CE/UL
Yes
Control Voltage
10M Ohm Potnentiometer Proportional Input
Load Current
10 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
180-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
RPC2440
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom DP4RSB60E40B5, DC Motor Reversing Contactor, 40 Amp, 18-32VDC control, 48VDC Load, 0.2s Soft Start, 0.5s Dynamic Brake
Features
40 Amp DC Semiconductor Motor Controller
Load voltage range up to 48VDC
Optional Start/Stop Ramp/Break
Panel Mount
LED Forward and Reverse input status indicator
18-32VDC or 4.5-15VDC control
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Spec
Crydom Part Number
DP4RSB60E40B5
Switching Type
DC Load
Approvals
ROHS,UL,CE,IEC
Control Voltage
18-32VDC
Load Current
40 Amp DC
Surge Capability (10ms)
140 Amp DC
Special Feature
FWD and REV LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
350g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom MCBC4825CF, Solid Sate Relay based Burst Fire Controller, 0-10V Input, 480VAC 25 Amp Load, 10 Cycles
Features
Selectable Proportional Burst Control Input
Ratings from 25A to 90 Amp @ 180-530 VAC
SCR output for heavy industrial loads
Zero voltage turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
MCBC4825CF
Switching Type
Burst Fire (10 Cycles)
ROHS/CE/UL
Yes
Control Voltage
0-10V Proportional Input
Load Current
25 Amp (rms)
Surge Capability
250 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
330-530VAC
Overvoltage Vpk
1200V
Termination Style
Terminal Plug & Screws
Unit Weight
87g
Factory Pack Qty
10
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Shinko BCR2R1016 Series Digital Indicating Controllers
• Program control, converter function are standard features
• 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
• Drip-proof / Dust-proof IP66 (front panel only)
• 9-step pattern (for SV and time) is a standard feature
• UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
• Each unit needs just 60 mm depth panel space
• EC Compliant (Details)
Specification
Shinko Part Number
BCR2R1000
Control Output
SSR 12VDC +/-15%, 40mA with (short circuit protected)
Input
Multirange (refer to datasheet)
Option 1
2nd Alarm Relay
Option 2
RS485 Comms
Mounting Style
48 x 96mm Panel Mount
Load Voltage Range
24VAC/DC
Termination Style
Screw
Weight
170g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BC Series Brochure
BC Series User Manual
BC Series RS485 Comms Manual
Shinko Product Guide
Fine Tuning Adjustments
Crydom HS501DR + 10PCV2425, Single Phase Proportional Phase Controller with Heatsink, 2-10VDC Input, 240V, 9 Amps
Features
Proportional Phase Control Input
Ratings from 25A to 90 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + 10PCV2425
Switching Type
Phase Angle (Random Crossing)
ROHS/CE/UL
Yes
Control Voltage
2-10V Proportional Input
Load Current
9 Amp (rms) @ 40 Deg C
Surge Capability
239 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
180-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
10PCV Series
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies