Search results for "탤ㄹㅔ문의 tsbusim 피해회복지원금긴급대출 가전내구제당일 탬스뷰선불유심현금화업체 단기연체기록대출 경상남도 당일 비대면내구제급전"
-
Burst Fire Controller, F431 Series 3 Phase, 380-440VAC, Cards Only
Oztherm F431 Series 3 Phase SCR Burst Controller Spare Card Set 100% Australian Made 3 Phase Burst Controller 4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control Fully enclosed IP20 Burst Fired switching Aluminium Frame Removable perspex Cover Applications Electrical Ovens, Kilns, or Furnaces Secondary or Direct Control only Controlled Power Applications Electric Boilers Smelting of Raw Metals Suitable for extreme environments such as mining Room/Chamber heating Available Options Current Limit and Trip AC (C) Power Limit (PW) Phase Loss Output (PH) Partial Load Failure (PLF) Loose Semiconductor Fuses (F) Internal Semiconductor Fuses (FI) Thermal Overlad Protection (T) Special Features Contact Us for Possible Replacement for customised features Specification Oztherm Part Number F431 Series 3 Phase Burst Controller (Cards Only) Rated Operationg Temperature 50°C SCR Configuration 3 Phase AC Swtich Control Voltage 4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration) Load Current 30 - 120Amps Per Phase Control Range 0-100% Special Feature (Optional) Current Limit & Trip AC, Power Limit, Phase Loss Alarm, Partial Load Failure Alarm, Thermal Overload Protection, Fuses Mounting Style Panel Mount Supply Voltage Range 380-440VAC +/-10% Soft Start 1-20mS Termination Style Screw Unit Weight up to 3kg Factory Pack Qty 1 Datasheet F431 Brochure F431 Installation and Commissioning Manual
$1,113.00 - $1,724.00
-
F920-A-XX-XX-XX Series AC/DC Current Transducer/Conditioner and Bipolar Power Supply, 9-36VDC Powered
F920-A-XX-XX-XX - Signal Conditioner and +/-15VDC Bipolar Power Supply with Adjustable High and Low C/O Relay Alarm. +/- 4V Bipolar Input, For External LEM Hall Effect Sensor Features Isolated measurement of AC or DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC Average RMS or DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty, Otherwise 4-6 weeks Datasheet Datasheet
$409.00 - $439.00