Search results for "가전제품렌탈내구제 탤ㄺ램 Banonpi 대학생무직자소액대출 바넌피선불유심내구제 철원군 무직자백수 소액급전 작업대출 주부모바일무직자대출"
-
DDB6U145N16L, 3 Phase Diode Rectifier Bridge, 145 Amp, 1600V, 42 x 94mm Package
Free Aus Post Shipping for $300 SpendInfineon DDB6U145N16L, 3 Phase Diode Rectifier Bridge, 145 Amp, 1600V, 42 x 94mm Package Features Package with DCB ceramic base plate Isolation voltage 3600 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering UL registered, E 148688 Applications Heat and temperature control for industrial furnaces and chemical processes Lighting control Motor control Power converter Advantages Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability High power density Specification Infineon Part Number DDB6U145N16L AC Line voltage 533V Device Configuration Three Phase Half Controlled Rectifier Bridge DC Output @ 100 Deg C 145 Amp Package Size W:94mm L:42mm D:30mm Itsm 1200 A VF(to) 0.75V Tj(max) 150°C rF 3.1mΩ Terminals M5 (4Nm) Hole Centres 68mm (M5) Gate Terminals N/A R th(j-c) 0.148°C/W R th(c-h) 0.33°C/W Weight 220g Isolation 3kV Factory Pack Qty 10 Certification UL Listed Infineon Headquarters Germany Datasheet Product Datasheet Alternatives See PSD192T/16 for alternative
Free Aus Post Shipping for $300 Spend$264.50
$312.11 inclGST -
CM600HA-24H, Single IGBT 600 Amp, 2400V, 80mm Base Width
Mitsubishi CM600HA-24H, Single IGBT 600 Amp, 2400V, 80mm Base Width Specification Schurter Part Number CM300HA-12H Configuration Single Insulated IGBT Nominal Voltage 1200V Collector Current (Ic) 600 Amp Collector Current (Tj < 150 Deg C) 1200 Amp Isolation 2500VAC Dimensions 80 x 110 x 36mm Mounting Style Panel Mount Operating Temperature Range (Tj Max) -40°C / 150°C Maximum Collector Dissipation 4100W Unit Weight 560g Factory Pack Qty 10 Datasheet Product Datasheet
$335.00
$395.30 inclGST -
SDM630Modbus-MID-V2-CL1 (SDM630-M), DIN Rail Mount kWh Meter, 3 Phase, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved
SDM630Modbus-MID-V2-CL1 (SDM630-M), DIN Rail Mount kWh Meter, 3 Phase, Class 1, 100 Amp Direct Connect input, w/ 2 x pulse outputs and RS485 Comms, MID Approved 3 x 100 amp Direct Connect RS 485 communication up to 38,400 bit/s as standard Optional Mbus Model available True RMS values of currents and voltages 2 x Pulse Outputs (1 Configurable) The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM630Modbus-MID-V2-CL1 (SDM630-M) Functions Three Phase Energy Meter Supply Voltage NA Nominal Measurement Range 415V L-L 230V L-N, 100 Amp Maximum Measurement Range 480V L-L 230V L-N, 100 Amp Nominal Current Input Direct connect 3 x 100 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility
$255.00
$300.90 inclGST -
SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516
Free Aus Post Shipping for $300 SpendEastron Europe SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516 Fast CPU for 100ms Communication response time For Solaxx or Growatt Inverters. Can be used for any 100 Amp Direct Connect application RS 485 communication up to 38,400 bit/s as standard Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) SAA Approved The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy Class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM230Modbus-MID-V2 (SLX) Functions Single Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 230V L-N 230V L-N, 100 Amp Maximum Measurement Range 276 L-N 230V L-N,100 Amp Nominal Current Input Direct connect 100 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 36mm x 100mm x 66mm (2 modules wide) Isolation 4kV RS485 2400-38400 b/s (100ms Response) Weight 250g Certification EN 61010-1 Installation Category III, SAA212516 Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility
Free Aus Post Shipping for $300 Spend$184.00
$217.12 inclGST -
T2 Protec T2-350-3+0-R, Uc = 350VAC SPD, 20kA (8/20uS). For 277VAC systems, 3 Pole + 0, DIN Rail Mount, Protection Modes L-PEN, Class II, Type 2, Type 1CA, Open Type 1 SPD Listed, with Remote Contact
Protec Protec T2 Protec T2-350-3+0-R, Uc = 350VAC Surge Protection Device (SPD) for AC Applications, 20kA (10/350uS), Varistor Voltage. For 277VAC systems, 3 Pole + 0, DIN Rail Mount, Protection Modes L-PEN, Class II, Type 2, Type 1CA, Open Type 1 SPD Listed, with Remote Contact Specifications Raycap part number T2 Protec T2-350-3+0-R Nominal Voltage Un 277VAC systems (for Uc = 350VAC ) No of Poles 3 Category IEC / EN / VDE Type 2/Open Type 1CA SPD Listed Location of use Sub Distribution Boards Protection modes L-PEN Additional Remote Contacts YES Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 20kA(8/20uS) 50kA Max Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$144.00
$169.92 inclGST -
FPT-135 800/1A 5P35 5VA, Protection Class CT, 800/1A, Class 5P35 5VA, 135 x 81mm Aperture
Heavy Item - No Free ShippingFPT-135 800/1A 5P35 5VA Protection Class CT, 800/1A, Class 5P35 5VA, 135 x 81mm Aperture Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2 Applications Protection Relays Safety Equipment Fault Monitoring ?? Specification Fastron Electronics Part Number FPT-135 800/1A 5P35 5VA Technology Protection Class Current Transformer Ratio 800/5 Aperture Size 81 x 135mm VA Rating 5VA Accuracy Class Class 5P35 Output 1 Amp AC (?%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10??C / 50??C Continuous Current (max) 800Amp x 1.3 Termination Style Screw Stanbards VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2 Unit Weight 7kg Factory Pack Qty 1 ?? Datasheet Product Installation Guide and Datasheet ??
Heavy Item - No Free Shipping$505.00
$595.90 inclGST -
Smart X96-5-MID, Panel Mount Multifuction Meter, Class 1, 173-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, Modbus RTU RS485 Comms, Self Powered, MID Approved
Eastron Smart X96-5-MID, Panel Mount Multifuction Meter, Class 1, 173-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, Modbus RTU RS485 Comms, Self Powered, MID Approved Metering and Numerical Display Adjustable tariff clock (Optional 4 Tarriffs), display of electric energy consumption in optional currency Modbus RTU as standard True RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 30 quantities (U, I, P, THD, IHD, S, PF, PA, f, f, MD, etc.). Accuracy class 1 Optional 2 or 4 tariff inputs, Digital Output and Input Ethernet communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD with Dual Metering and PF Displays Specification Eastron Part Number Smart X96-5-MID Functions Power Quality Meter, Energy Meter Aux Supply Through Measurement Inputs Nominal Measurement Range 173-480V L-N, 1/5 Amp Maximum Measurement Range 280V L-N, 1/5 Amp Pulse Outputs 2 x Digital Outputs (shared with Alarm function) Alarm 2 x Digital Outputs (shared with Pulse function) Tariff Input 1 (Optional 4 x ) Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 2.5kV (1 Min) RS485 2400-38400 b/s Weight 500g Certification MID, UL Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Operating Temperature -25 →+55 °C Datasheet Product Datasheet User Manual Modbus Registers
$385.00
$454.30 inclGST -
BA1-ND21-2A, Indicator, 48x24mm, 12-24VDC, 4-20mA Input, 0-100.0 Display Range
BA1-ND21-2A, Indicator, 48x24mm, 12-24VDC, 4-20mA Input, 0-100.0 Display Range 3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Each unit needs just 40 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number BA1-ND21-2A Control Output 1 (Heat) N/A Control Output 2 (Cool) N/A Input 4-20mA (0-100.0) Alarm N/A Option 1 N/A Mounting Style 48 x 24mm Panel Mount Supply Voltage 5VDC Termination Style Screw Weight 100g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet BA1 Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$69.50
$82.01 inclGST -
F920-A-XX-XX-XX Series AC/DC Current Transducer/Conditioner and Bipolar Power Supply, 9-36VDC Powered
F920-A-XX-XX-XX - Signal Conditioner and +/-15VDC Bipolar Power Supply with Adjustable High and Low C/O Relay Alarm. +/- 4V Bipolar Input, For External LEM Hall Effect Sensor Features Isolated measurement of AC or DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC Average RMS or DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty, Otherwise 4-6 weeks Datasheet Datasheet
$409.00 - $439.00
-
F923 DC Series Current Transducer with Adjustable High and Low C/O Relay Alarm
F923 Series DC Current Transducer with Process Outputs & High and Low C/O Alarm Features Isolated measurement of DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-DC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$552.00 - $595.00
-
F923 DC Series Current Transducer with Adjustable High and Low Solid State Relay Alarm
F923 Series DC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-DC-XX Functions Single Phase DC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$552.00 - $595.00
-
F921 DC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
F921 DC Series Current Transducer 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm Features Isolated measurement of DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-DC-XX-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 2500 Amp with External Sensor Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST