RCS-1200-2000 Three-Phase Flexible Current Sensor System (Rogowski Coils):
The RCS-1200 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-1200-2000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
2000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 2000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
4 Inch
Coil Circumference
12 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
VX2-UMNA-A2, Temp Controller, 48x96mm, 100-240VAC, Multirange Input, Relay Output, 2 Alarms
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX2-UMNA-A2
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Control Output 2 (Cool)
N/A
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
N/A
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Fastron Electronics SCT-F36-250-5A, 5 Amp, 250Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-250-5A
Technology
Split Core AC Current Transformer
Ratio
250/5 Amp
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
250Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Infineon TT104N14KOF-K Dual Thyristor Module
Features
Pressure Contact Technology
Optimised for Deep Cycling
Electrically insulated base plate
Very low forward voltage drop
Very low leakage current
3600V Isolation
Industrial standard package
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Rectifiers for UPS
Battery Chargers
Center Tapped Transformers
Specification
Infineon Part Number
TT104N14KOF-K
Vrrm
1400V
Diode Configuration
Common Cathode Dual Thyristor Module
IF(av) @ 85 Deg C
104 Amp
Package Size
TO-240AA W:20mm L:93mm D:30mm
Itsm
2.05 kA
VF(to)
0.85V
Tj(max)
125°C
rF
2.15mΩ
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Trigger Current
120mA
R th(j-c)
0.37°C/W
R th(c-h)
0.10°C/W
Weight
160g
Mounting Torque
4 Nm (4 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See VSKC91/16 for Solder Bonded alternative
Crouzet Syr-Line Single Pole Multifunction Timer With SP-NO/NC Contacts
MDE Timers Syrline 48x48mm - 1 Relay 5A :
Large LED or LCD Screen (13.2 mm)
Multi-function and single-function
Basic & Advance configuration modes
Multi-range (0.05 s – 9999 h)
Multi-voltage (24-240 V AC/DC)
1 or 2 relay outputs (Changeover)
Memory option in event of a break in supply (Note Memory available for A function only in LCD models)
Lock function › Up or down timing
DIN Sized (48x48 mm) Housing
Compact body (63 mm long)
Water & Dust-proof (IP66)
8-Pin
Multifunction Timers Include The Following :
Function A Delay on energisation 1 relay (With or without Memory)
Function B Timing on impulse one shot 1 relay
Function C Timing after impulse 1 relay
Function H Timing on energisation 1 relay
Function D Symmetrical Flashing (OFF start) with Memory 1 relay
Function Di Symmetrical Flashing (ON start) with Memory 1 relay
Specification
Crouzet Part Number
MDE1R0524U (Syr-Line Timer Single Pole 5A Multifunction, 24VAC/DC, 48x48mm)
Function
Multifunction Timer A - B - C - H - D - Di
Nominal Voltage
24VAC/DC
Digital Output
1 x C/O (SPDT) (Changeover -Single Pole Double Throw), 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 0.05→9999h
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Memory
YES -> Function A only for MDE (LCD display) series
Isolation
1kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
8 Pin Base
Weight
80g
Certification
CE, cULus,CCC, ROHS, Reach, WEEE
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP66 (Front), IP40 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
TA800E-LB24, BLUE LED Bead Replacements for 24AC/DC TRIB, TRI Series Indicators
Pushbutton Indicator Switches are a combinations of LED indicator Series and Momentary Pushbutton Switches. LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24AC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TA800E-LB24
Functions
LED Indicator Bulb Replacement
Nominal Voltage
24AC/DC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Blue LED
Approvals
CE
Weight
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Crydom DR24D06, Solid State Relay, 4-32VDC control, 6 Amp 24-280VAC Output, Slimline, Din Rail Mount, LED status Indicator
Features
Ratings from 3 Amp, 6 Amp, 12 Amp 1-100VDC, 1-60VDC, 24-280VAC, 48-600VAC
DIN Rail Mount
SCR output for reliable AC switching, or Mosfet for DC Switching
Ultra slim package
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
DR24D06
Switching Type
DC
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
6 Amp (rms)
Surge Capability (10ms)
285 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
50g
Factory Pack Qty
20
Datasheet
Product Datasheet
Equivalent
Similar part
ks32-60-24z2-f41f-1z-c2-4
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Infineon T828N04TOF Thyristor(SCR) Capsule
Features
Very low forward voltage drop
Very low leakage current
International standard package
48/14 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Controlled Rectifiers
AC Switch
Battery Chargers
Phase Controllers
Water Cooled AC switches
Power Factor Correction
Specification
Infineon Part Number
T828N04TOF
Vrrm
1600V
SCR Configuration
Thyristor(SCR) Capsule PUK
IF(av) @ 85 Deg C
828 Amp
Package Size
ø48 x 14mm
Itsm
13.5 kA
VF(to)
1V
Tj(max)
125°C
rF
0.23mΩ
Gate Terminals
Faston 4.8 x 0.8mm & 2.8 x 0.8mm
R th(j-c) (double sided cooled 180°sin)
0.045°C/W
R th(c-h) (double sided cooled)
0.01°C/W
Weight
110g
Clamping Force
5.5 - 8kN
Factory Pack Qty
12
Certification
ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
T1410N04TOF
T880N16TOF
Heatsink
Heatsink Profiles
Crydom CWD2450P, Solid State Relay, Single Phase 3-32VDC Control, 50A, 24-280VAC Load. High surge w/Varistor
Features
Ratings from 25A to 125 Amp @ 24-280VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CWD2450P
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
50 Amp (rms)
Surge Capability
850 Amp (peak)
Special Feature
LED Status Indicator, High Surge, Internal Over Voltage Protection
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See CWD4890H for stocked equivalent (no overvoltage protection).
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom DRA-CN240A05, Slimline Relay & Socket, 3-12VDC Coil, 2 Amp 24-280VAC Load
Features
Output 2Amp @ 250VAC
3-12VDC Control input
DIN Rail Mount
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
DRA-CN240A24
Switching Type
250VAC 2 Amp Load SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
3-12VDC
Load Current
2 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
250VAC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Datasheet
Relay Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket
IMR122, Insulation Monitoring Relay For 0-520VAC 13.5-440Hz System with 2 Outputs (1 C/O + 1NO), Aux Supply Voltage 24-240VAC/DC. L/PE Moitoring, For Earth Resitance Monitoring
Features
Monitors insulation resistance of unearthed IT Systems in compliancewith IEC 61557-8, EN 50155, IEC 61373 and EN 45545 HL-2/3
Measuring input L-PE with line voltages upto 520V AC
Wide auxiliary supply voltage range 24V – 240V AC/DC
Adjustable trip resistance value from 1K to 100Kohm
2 Relay outputs (1C/O + 1NO) for fail safe and non fail safe operation
Test / Reset function with Manual and remote facility
Configurable Auto / Manual Reset
LED indication for insulation fault , Power and Relay output
DIN Rail / Base Mounting
EC Compliant
Can Replace:
-CM-IWS.2S(ABB)
-CM-IWS.1S(ABB)
-3UG4581-1AW31(Siemens)
-IL5880 (DOLD)
-RI-22 (Contrel)
-IR140Y-4 (Bender)
-IR470LY-40 (Bender)
Specification
GIC Controls Part Number
IMA122
Control Output
2 Relay outputs (1C/O + 1NO) for fail safe and non fail safe operation . (NO 5 Amp, NC 3 Amp)
Adjustable Trip Range
1K to 100Kohm
Input
External PT100 Sensor (not supplied)
Mounting Style
17.5 x 75mm Din Rail Mount
Supply Voltage
24 - 240VAC/DC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
ROHS
Yes
Standards
IEC 61000, EN50121, EN50155, EN55011, IEC60255-27, EN 45545-2,HL-2/3, IEC 60255-27, IEC 60068, UL508 See datasheet for full revision details
CE
Yes
Datasheet
Datasheet
Crydom MCBC4825CF, Solid Sate Relay based Burst Fire Controller, 0-10V Input, 480VAC 25 Amp Load, 10 Cycles
Features
Selectable Proportional Burst Control Input
Ratings from 25A to 90 Amp @ 180-530 VAC
SCR output for heavy industrial loads
Zero voltage turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
MCBC4825CF
Switching Type
Burst Fire (10 Cycles)
ROHS/CE/UL
Yes
Control Voltage
0-10V Proportional Input
Load Current
25 Amp (rms)
Surge Capability
250 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
330-530VAC
Overvoltage Vpk
1200V
Termination Style
Terminal Plug & Screws
Unit Weight
87g
Factory Pack Qty
10
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement