Trent FGM6DC-2PL-320 80A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 80 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 80A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
80 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Fastron FRTD-PT100-50, Pt100 Air Temperature Sensor, 50mm shaft length, 77 x 77 x 55mm Body
4-20mA Output 2 Wire
Temp Measurement for 0 to 100 Deg C Max
190 x 18mm with 1M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Pt100 Temp Sensing Elements
Specification
Fastron Part Number
FRTD-PT100-50
Sensor Type
RTD (Temperature) & Thin Film Capacitor (Humidity)
No of Wires
3
Shaft Length
190mm
Shaft Thickness
18mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram
Current Transducer, AT-AA9-A-1, AC Current Transducer, Average RMS, 10 Amps, 100-240VAC/DC Aux, 4-20mA output output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA9-A-1
Control Output
4-20mA Average RMS
Input
0-10 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Current Transducer, AT-AA9-D-4, AC Current Transducer, Average RMS, 5 Amps, 24VDC Aux, 0-10V output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA8-D-4
Control Output
0-10V Average RMS
Input
0-5 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
24VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Current Transducer, AT-AA9-D-1, AC Current Transducer, Average RMS, 10 Amps, 22-60VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA9-D-1
Control Output
4-20mA Average RMS
Input
0-10 Amp rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Current Transducer, AT-AA9-D-4, AC Current Transducer, Average RMS, 10 Amps, 22-60VAC/DC Aux, 0-10V output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA9-D-4
Control Output
0-10V Average RMS
Input
0-10 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FPC1-63-22-230VAC, 4 Pole 2 x SPST NO, Configuration_2 x SPST (2 x NC) Modular Contactor 440VAC 63 Amp 50/60Hz, 230VAC Coil Voltage
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
FPC1-63-22-230VAC
Switching Type
2 x SPST NO, Configuration_2 x SPST (2 x NC)
Approvals
CE
Coil Voltage
230VAC 50/60Hz
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Datasheet
Auxiliary Contacts Selection Guide
Techsem MDK110-16-223F3, Dual Diode Module, Common Cathode, 110 Amp, 1600V, 22mm Package
Features
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
2900V Isolation
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Deep Cycle Operation
Rectifiers for UPS
Battery Chargers
Specification
Techsem Part Number
MDK110-16-223F3
Vrrm
1600V
Diode Configuration
Dual Diode Module, Common Cathode
IF(av) @ 100 Deg C
110 Amp
Package Size
W:20mm L:93mm D:30mm
Itsm
2.6 kA
VF(to)
0.8V
Tj(max)
150°C
rF
1.74mΩ
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
N/A
R th(j-c)
0.27°C/W
R th(c-h)
0.20°C/W
Weight
175g
Mounting Torque
4 Nm (4 Nm Terminals)
Factory Pack Qty
15
Certification
UL Listed
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See VSKC91/14 for Solder Contact alternative of Contact Us for Possible Replacement for alternative part
Electronicon E50.N11-903NT0 620uF 2kVDC, DC Link, 40Amp, H:110mm x D:85mm, M12 Mounting Stud, M6 Terminals
Characteristics and utility
620uF, 2000VDC0.0kvar 20kvar
DC Link Film Capacitor
Connector type - Stud inserts
Indoor mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
E50.N11-903NT0 90uF 2kVDC
Technology
DC Link
Dimensions
H:100mm x D:85mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
2kVDC
Inom
40 Amps
Capacitance
90uF
Tolerance On Capacitance
+/- 10%
Lifetime
200,000 Hours
Termination Style
M6 Screw Inserts
Unit Weight
1kg
Factory Pack Quantity
2
Datasheet
Product Catalogue
VA1021B, Liquid PH Tester & Temperature Tester Portable with External BNC Connected Sensor. Range 0-14PH, 0-50 Deg C Accuracy 0.02PH/0.5 Deg C, WITH BLUETOOTH AND APP
Features
Portable /Battery Powered 3 x AAA (500 Hours)
External Sensor (BNC)
Range 0-14PH, 0-50 Deg C
Accuracy 0.02PH/0.5 Deg C
Bluetooth Comms
Free App
Specification
Datasheet
Datasheet
VA8045, Moisture Meter (Inductive) for 10 Grades of Wood Density. Range 40 to 80%, +/-1% Resolution 0.5%, +/-1 Deg C. Surface Probe Type 10 Grades of Wood Density Available. Automatic Temperature Compensation, Measurement through HF Electromagnetic waves
Features
Portable /Battery Powered 3 x AAA
For 10 Grades of Wood Density.
Range 40 to 80%, +/-1% Resolution 0.5%, +/-1 Deg C.
Surface Probe Type
Specification
Datasheet
Datasheet