Search results for "multimeter"
-
FATL500D420T, AC Current Transducer, 500Amp Measurement, 36mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, Terminal Version
Fastron Electronics FATL500D420T, AC Current Transducer, 500Amp Measurement, 36mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, Terminal Version Features Quick Release 36mm Split Core System Cale Mount 4-20mA Output 24VDc Aux Rated System Voltage 0.60/2.5kV 0.5M Flying Leads Applications Control Systems Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number FATL500D420T Technology 36mm Split Core AC Current Transformer Ratio 500/4-20mA Aperture Size ø 36 mm VA Rating N/A Accuracy Class Class 1 Output 4-20mA (+20%) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style Screw Terminals Unit Weight 250g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$219.00
$258.42 inclGST -
LAS 50-TP, C/L Hall Effect Current Sensor, 50 Amp, 2.5V ref, PCB Mount, X = 1%, 5kV Isolation
LEM LAS 50-TP Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 100kHz Closed loop transducer using Hall effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LAS 50-TP Technology Open Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 50 Amp Measurement Range +/-150 Amp Output 2.5V +/-0.625*Ip/Ipn Isolation 5 kV Bandwidth DC-100 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style Through Hole PCB Unit Weight 20g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$47.06
$55.53 inclGST -
LV 100-2000/SP15, C/L Hall Effect Voltage Transducer, 2000V, 50mA Output
LEM LV 100-2000/SP15, C/L Hall Effect Voltage Transducer, 2000V, 50mA Output Features Bipolar and insulated voltage measurement up tp 3000VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 100-2000/SP15 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary RMS Voltage 2000V Measurement Range +/- 3000V Output 50 mA Isolation 9 kV Response 70uS Mounting Style Panel Mount Operating Temperature Range -10°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 870g Factory Pack Quantity 6 Datasheet Product Datasheet
$1,298.00
$1,531.64 inclGST -
HAL 100-S, O/L Hall Effect Current Sensor, 100 Amp, +/-4V Output, 15 x 20mm Aperture
HAL 100-S O/L Hall Effect Current Sensor, 400 Amp, +/-4V Output, 15x20mm sqr X = 1% Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAL 100-S Technology Open Loop Hall Effect Aperture 20 x 15mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 100 Amp Overload Capability 30,000 Amp Output +/-4 V Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style PCB Unit Weight 75g Factory Pack Quantity 10 Datasheet Product Datasheet
$110.64
$130.56 inclGST -
FESCT-F36-500A/100mV, 500A/100mV Measurement, Class 1 Split Core CT's, 36mm Aperture
Fastron Electronics FESCT-F36-500A/100mV, 500A/100mV Measurement, Class 1 Split Core CT's, 36mm Aperture Features Quick Release Split Core System Cable Mount 100mVmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with -2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements  Specification Fastron Part Number FESCT-F36-500A/100mV Technology Split Core AC Current Transformer Ratio 500/100mV Aperture Size ø 36 mm VA Rating 1VA Accuracy Class Class 1 Output 100mV (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (mVx) 500Amp x 1.2 Termination Style 0.9M Flying leads with -2.0 Connector Unit Weight 170g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide
$69.00
$81.42 inclGST -
Rish Xmer 155/80 3000/5 SCCT Class 0.5 20VA Series Split Core Current Transformer
Rishabh Xmer CT Split 155/80 3000/5 SCCT Class 0.5 20VA Series Split Core Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Rishabh Part Number Rish Xmer 155/80 3000/5 SCCT Class 0.5 20VA Technology Split Core AC Current Transformer Ratio 3000/5 Aperture Size 85 x 125mm VA Rating 20VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 3000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9  Datasheet Product Datasheet Â
$295.00
$348.10 inclGST -
FP250160P, 2500/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm
FP250160P, 2500/5 Amp Split Core CT, Class 0.5 15VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Electronics Part Number FP250160P Technology Split Core AC Clip On Current Transformer Ratio 2500/5 Aperture Size 80 x 160mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2500Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1  Datasheet Product Datasheet Installation Guide Â
$265.00
$312.70 inclGST -
HTA 400-S, O/L Hall Effect Current Sensor, 400 Amp, +/-4V Output
LEM HTA 400-S Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 1000 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTA 400-S Technology Open Loop Hall Effect Aperture ø32mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 400 Amp Measurement Range +/-1000 Amp Output +/-4 V Isolation 4 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 230g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$138.50
$163.43 inclGST -
AT-AAO(0-1)-A-1, AC Current Transducer, 1 Amp Average RMS, 100-240VAC/DC Aux, 4-20mA output
Current Transducer, AT-AAO(0-1)-A-1, AC Current Transducer, 1 Amp Average RMS, 100-240VAC/DC Aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type) Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number AT-AAO(0-1)-A-1 Control Output 4-20mA Average RMS Input 0-1 Amp Rms Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1  Datasheet Product Datasheet
$209.00
$246.62 inclGST -
Xmer CT Split 93/30SC 250/5 Class 1 3.75VA, 23 x 33mm Aperture
Xmer CT Split 93/30SC 250/5 Class 1 3.75VA, 23 x 33mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Rishabh Part Number Xmer CT Split 93/30SC 250/5 Class 1 3.75VA Technology Split Core AC Current Transformer Ratio 250/5 Aperture Size 23 x 33mm VA Rating 3.75VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Unit Weight 600g Factory Pack Qty 9  Datasheet Product Datasheet
$85.00
$100.30 inclGST -
FATL400D420T, AC Current Transducer, 400Amp Measurement, 36mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, Terminal Version
Fastron Electronics FATL400D420T, AC Current Transducer, 400Amp Measurement, 36mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, Terminal Version Features Quick Release 36mm Split Core System Cale Mount 4-20mA Output 24VDC Aux Rated System Voltage 0.60/2.5kV 0.5M Flying Leads Applications Control Systems Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number FATL400D420T Technology 36mm Split Core AC Current Transformer Ratio 400/4-20mA Aperture Size ø 36 mm VA Rating N/A Accuracy Class Class 1 Output 4-20mA (+20%) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style Screw Terminals Unit Weight 250g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$219.00
$258.42 inclGST -
DHR 400 C420, Hall Effect Current Sensor, 400Amp , True RMS 4-20mA output
LEM DHR 400 C420, Hall Effect Current Sensor, 400Amp , True RMS 4-20mA output Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ?32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 400 C420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 400 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6  Datasheet Product Datasheet
$392.00