VA1021B, Liquid PH Tester & Temperature Tester Portable with External BNC Connected Sensor. Range 0-14PH, 0-50 Deg C Accuracy 0.02PH/0.5 Deg C, WITH BLUETOOTH AND APP
Features
Portable /Battery Powered 3 x AAA (500 Hours)
External Sensor (BNC)
Range 0-14PH, 0-50 Deg C
Accuracy 0.02PH/0.5 Deg C
Bluetooth Comms
Free App
Specification
Datasheet
Datasheet
VAT810, CO2 Indoor Air Quality Monitor. Desktop Mount, 5VDC Supply (1.5W). Temperature Measurement Range -20 to 50 Deg C Accuracy +/-0.5 Deg C. Humidity 0-100% +/-3%RH, CO2 300-3000ppm +/-(50ppm + 3%). With Sound and Light Alarm, Modbus RS485
Features
Desktop Mount
5VDC Supply (1.5W)
Temperature Measurement Range -20 to 50 Deg C Accuracy +/-0.5 Deg C Humidity 0-100% +/-3%RH
CO2 300-3000ppm +/-(50ppm + 3%)
With Sound and Light Alarm
Capacitive Humidity Sensor
NDIR CO2 sensor
IP40
125x85x30mm
Touch Key Operation
Specification
Datasheet
Datasheet
Fastron Electronics FGC1-D3210-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole 3 x NO + 1NO, Nominal Current = 32 Amps(AC-3) @ 240/400/500/690V
Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
CE, CB Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Fastron Electronics Part Number
FGC1-D3210-230VAC
Functions
3 Pole + 1NO Contactor
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
32 Amp Continuous @ 55 Deg C
Main Contacts
3 x NO
Auxiliary Contacts
1 x NO
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
2.3W
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM CD 100-S/SP5, O/L Hall Effect Current Sensor, 2 x 1000 Amp, +/-5V Output
Features
Bandwidth DC to 5kHz
Closed loop transducer using Hall effect (Compensated)
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Single or 3 Phase Inverter
Propulsion and Breaking Chopper
Propulsion Converter
Auxiliary Converter
Railway Security System
Specification
LEM Part Number
CD100-S/SP5
Technology
Closed Loop Hall Effect
Aperture
ø40mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
2 x1000 Amp
Output
+/-5 V
Isolation
6 kV
Bandwidth
DC-5 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 80°C
Accuracy
2.5%
Unit Weight
1kg
Factory Pack Quantity
10
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
HF121-12/0.4-16.7-7%K, 16.7kVar 400VAC 7% Detuned Reactor for Power Factor Correction Capacitor Banks
Specification
Technical Features
HF121-12/0.4-16.7-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
3.678mH
Inductance (mH @ 525VAC)
Nominal Power
16.7kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
21kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
Electronicon 275.546-703800/221K02, 10kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 75 x 230(+32 +5/-2)mm Gas Filled, 3 x 38.5uF
Characteristics and utility
10kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.546-703800/221K02
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
75 x 230(+32)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
10 Kvar
Capacitance
3 x 38.5uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 11 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
1.6kg
Factory Pack Quantity
30
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Electronicon 275.546-604800/221K02, 12.5kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 75 x 230(+32 +5/-2)mm Gas Filled, 3 x 48.1uF, Internal Discharge Resistors
Characteristics and utility
12.5kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.546-604800/221K02
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
75 x 230(+32)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
12.5 Kvar
Capacitance
3 x 48.1uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 13.7 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
1.6kg
Factory Pack Quantity
30
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Electronicon 275.266-607700/221K02, 20kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 77uF, Internal Discharge Resistors Included, Single Sided Terminals
Characteristics and utility
20kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.266-607700
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
75 x 230(+32)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
20 Kvar
Capacitance
3 x 77uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 22 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
1.5kg
Factory Pack Quantity
30
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Fastron Electronics LZZBJ6-12/185h/2 400/1A 5P20 10VA 6.6kV, HV Protection Class Current Transformer
Features
Panel Mount
1 Amp Output
Self Powered
Rated System Voltage 6.6kV
Applications
Indoor Substations
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
LZZBJ6-12/185h/2 400/1A 5P20 10VA 6.6kV
Technology
HV AC Current Transformer
Ratio
400/1 Amp
Aperture Size
N/A
VA Rating
10VA
Accuracy Class
Class 5P20
Output
1 Amp (+20%)
Isolation
28kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
400Amp x 1.2
Termination Style
M12 Inserts
Unit Weight
28kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron Electronics LZZBJ6-12/185h/2 200/1A 5P20 10VA 6.6kV, HV Protection Class Current Transformer
Features
Panel Mount
1 Amp Output
Self Powered
Rated System Voltage 6.6kV
Applications
Indoor Substations
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
LZZBJ6-12/185h/2 200/1A 5P20 10VA 6.6kV
Technology
HV AC Current Transformer
Ratio
200/1 Amp
Aperture Size
N/A
VA Rating
10VA
Accuracy Class
Class 5P20
Output
1 Amp (+20%)
Isolation
28kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
M12 Inserts
Unit Weight
28kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Trent FGM6DC-2PL-500 350A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 350 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-400 350A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
350 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
5.7kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet