Fastron FRTD-Transmitter-0-400-420-24, Pt100 , 4-20mA Transmitter, 0 to 400 Deg C, 24VDC Supply
Class A Accuracy
Steel Insulated Cable
Low Long Term Drift
Rated for 0 to 220 Deg C Max
Spring Cable Connection
60mm Jaw Clip
Specification
Fastron Part Number
FRTD-Transmitter-0-400-420-24
Sensor Type
Pt100 to 4-20mA Transmitter
No of Wires
3
Shaft Length
N/A
Shaft Thickness
N/A
Accuracy
Class B
Temperature Range
0 to 400 Deg C
Span/ Zero Adjustment
YES
Weight
50g
Factory Pack Qty
1
Fastron S-2P-C, 2 Pole Ceramic Terminals for Thermocouple
Rated for 0 to 650 Deg C Max
Specification
Fastron Part Number
S-2P-C
Sensor Type
For RTD's or Thermocouples
No of Wires
3
Shaft Length
N/A
Shaft Thickness
N/A
Accuracy
N/A
Temperature Range
Up to 650 Deg C
Span/ Zero Adjustment
YES
Weight
50g
Factory Pack Qty
1
Fastron Electronics F41F-S, Spacer for F41F Series Slim Relays
Features
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed
Specification
Fastron Part Number
F41F-S
Approvals
UL94V0
Dimensions
76.6 x 94.7 x 6.2
Suits Relay Type
Fastron F41F Series
Unit Weight
10g
Factory Pack Qty
100
Datasheet
Datasheet
Fastron Electronics DEVD200E1DA4, Contactor SPST-NO Non Polar, 200 AMP, 12-800VDC, 12-36VDC Coil, SPST-NO Auxiliary Contact
Features
Hermetically Sealed with inert gas
CE, CCC Approved
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Side mounted version available
Specification
Fastron Part Number
DEVD200E1DA4
Main Contact Type
SPST-NO (silver plated copper)
Auxiliary Contact Type
SPST-NO
Coil Voltage
12-36VDC
Load Current
200 Amp
Mechanical Life @ 0 Amp
200,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
Lead Wire Connection
Special Feature
N/A
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 800VDC
Standards
CE, CCC
Termination Style
M8
Unit Weight
550g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics FESCTHY-19-50-100mA, 50Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 19x19mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESSCT-19-50-100mA
Technology
Split Core AC Current Transformer
Ratio
50/100mA
Aperture Size
19 x 19mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mA AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
50Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics FESCTHY-32-150-100mA, 150Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 32x32mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/2kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESCTHY-32-150-100mA
Technology
Split Core AC Current Transformer
Ratio
150/100mA
Aperture Size
32 x 32mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mA AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
150Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
SDM54-MODBUS-MID, Ultra Compact DIN Rail Mount kWh Meter, 3 Phase, 500VAC L-L, Class 1, 100 Amp Direct Connect input, w/ 2 x Configurable Pulse Outputs and RS485 Comms, MID Approved. Built for EV Chargers
Features
3 x 100 amp Direct Connect
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages
2 x Pulse Outputs (2 x configurable)
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM54-MODBUS-MID
Functions
Three Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
415V L-L 230V L-N, 100 Amp
Maximum Measurement Range
500V L-L 230V L-N, 100 Amp
Nominal Current Input
Direct connect 3 x 100 Amp
Pulse Output
2 x Passive (Configurable)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Trent FGM6S-4P-400M 400A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 60kA 400 Amp, 400/690VAC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
4 Pole Disconnect
60kA Short Circuit Rating @400VAC
Suitable for Main Incoming Breaker
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Trent Part Number
FGM6S-4P-400M 400A
Functions
4 Pole MCCB
Nominal Voltage
400/690VAC @ 50/60Hz
Nominal Current Range
400 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
8kV
Operating Temperature
-25 to 50 Deg C
Mechanical Operations
20,000 Ops
Insulation Voltage
800V
Short Circuit Current (Ics)
60kA
Approvals
KEMA EUR, CE
Standards
IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
5.1kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Trent FGM6DC-2PL-320 250A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 250 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 250A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
250 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Trent FGM6DC-2PL-320 200A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 200 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
2 Pole Disconnect
20kA Short Circuit Rating @400VAC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 200A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
200 Amps
Trip Delay Time
< 50ms
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration