Fastron Electronics FEFA200-20-M, 2 Stage EMC (RFI) Line Filter, 250VAC, Very High Symmetrical and Asymmetrical Attenuation
Features
Line filter in standard and medical version
2-stage - high attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Fastron Part Number
FEFA200-20-M
Rated Voltage
250V
Rated Current
20A
Filter Stages
2 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.5mA
Mounting
Panel Mount - Case FF
Material
Metal
Termination Style
Screw
Weight
840g
Factory Pack Qty
4
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Fastron Electronics FEFA200-50-M, 2 Stage EMC (RFI) Line Filter, 50 Amp 250VAC, Very High Symmetrical and Asymmetrical Attenuation
Features
Line filter in standard and medical version
2-stage - high attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Fastron Part Number
FEFA200-50-M
Rated Voltage
250V
Rated Current
50A
Filter Stages
2 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.5mA
Mounting
Panel Mount - Case FF
Material
Metal
Termination Style
Screw
Weight
1.2kg
Factory Pack Qty
4
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Fastron FC5-M-W-2-G-2 PID Controller, 100-240VAC with 2 Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-M-W-2-G-2
Control Output
SSR/Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ SSR 12VDC @20mA
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 Alarms standard
Comms
Optional (Modbus RTU 38400 Max Baud Rate)
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron Electronics GT-AV(0-500)-A-1, AC Voltage Transducer, 0-500V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-500)-A-1
Control Output
4-20mA Average RMS
Input
0-500VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics FWBV414H29-500AC-420, AC Voltage Transducer, 0-500V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request)
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
FWBV414H29-500AC-420
Control Output
4-20mA Average RMS
Input
0-500VAC, 50/60Hz (25Hz - 1kHz Available on Request)
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics FWBV414H29-300AC-420, AC Voltage Transducer, 0-300V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request), Low Profile
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 42 x 50 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
FWBV414H29-300AC-420
Control Output
4-20mA Average RMS
Input
0-300VAC, 50/60Hz (25Hz - 1kHz Available on Request)
Over Range
x 1.2 (Continuous)
Operating Temperature
-25 - 70°C
Load Voltage
100-240VAC/DC
Termination Style
Screw
Mounting Style
DIN Rail Mount
Dimensions
H:102 x W:42 x D:50mm
Standards
EN50022
Case Material
PC - UL 94 V0
Weight
250g
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter 6102.3200, IEC Appliance Inlet C18, Screw Panel Mounting, Front Side, Quick connect terminals 4.8 x 0.8 mm
Features
Panel Mount : Screw Mounting from Front Side
Appliance Inlet C18/M Socket acc to IEC 60320-1
4.8 x 0.8mm Fastron Pins
120 °C pin Temperature
Quick connect terminals 4.8 x 0.8 mm
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 120 °C, 10A, Protection Class I
Other Thickness versions available on request
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Schurter Part Number
6102.3200
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
Panel Thickness
N/A Screw Mounted
Operating Temperature
-25°C to 120°C
Filter Type
N/A
Fuse Holder
N/A
Line Switch
N/A
Mounting
Panel Mount with Screws
Material
Thermoplastic, black, UL 94V-0
Termination Style
C18/M to Faston 4.8 x 0.8 mm
Weight
25g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV
VDE/UL/CSA/CE/ROHS
Yes
Datasheet
Product Datasheet
Techsem MDC182-16-216F3B, 182 Amp, 1600V, Dual Diode Module
Features
Pressure Contact Technology
Electrically insulated base plate
Improved temperature and power cycling
Planar passivated chips
Very low forward voltage drop
Very low leakage current
3600V Isolation
Industrial standard package
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
For single and three phase bridge configurations
Field supply for DC motors
Input rectifiers for PWM inverter
Specification
Techsem Part Number
MDC182-16-216F3B
Vrrm
1600V
Diode Configuration
Single Diode Module
IF(av) @ 85 Deg C
181 Amp
Package Size
TO-240AA W:20mm L:93mm D:30mm
Itsm
6.4 kA
VF(to)
0.80V
Tj(max)
150°C
rF
0.96mΩ
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Trigger Current
N/A
R th(j-c)
0.22°C/W
R th(c-h)
0.08°C/W
Weight
320g
Mounting Torque
2.5 Nm (5 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Fast ONE AHF 100A-400V, Active Harmonic Filter & Static Var Generator, 70Kvar/ 100 Amp, 3 Phase + N, 400VAC +/-20%, WALL MOUNT
For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. and for the filtering or control of Harmonic Distortion
Features
Automatic Power Factor Correction up to Cos φ = 0.99
Overtemperature Alarm
Optional RS485 Comms
IEC 654-1, UL Approved
3 Year Fastron Electronics Warranty
Modular Construction for Rack or Wall Mount Installations
Perfect for Residential Applications
Stack multiple modules for larger Power Factor Correction Requirements
Specification
Fastron Part Number
Fast ONE AHF 100A-400V
Function
Reactive Power Correction & Active Harmonic Filter
Current /Load Rating
100 Amp per Phase /70Kvar
Nominal Voltage (Un)
400VAC Line to Line 50Hz
Switch Delay Time
Instant Correction/Inverter Based
Desired Harmonic
0.99 IND - 0.99 CAP
LCD Display Accuracy
IGBT Temp, Grid Current Grid THDi, Grid PF, Grid Imbalance
Current imbalance
< 5%
Comms
RS485 (Optional)
Mounting Style
Wall Mount
Termination Style
Screw
Dimensions
486x220x610mm
Weight
60kg
Certification
EN 61000-6-4:2007+A1:2011
EN 61000-6-2:2005
EN 61000-3-2:2014
EN 61000-3-3:2013+A1:2019
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013
Enclosure protection
IP21
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Datasheet
User Manual
Electronicon 275.269-416600/221K02 30kvar 440V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 280(+15)mm Gas Filled, 3 x 166uF, SINGLE SIDED TERMINALS, Internal Discharge Resistors
Characteristics and utility
37.2kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors NOT INCLUDED
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.269-416600/221K02 30kvar 440V 50Hz
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
95 x 280(+15)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
440V @ 50Hz
Kvar
30 Kvar @ 440VAC, 25Kvar@ 400VAC
Capacitance
3 x 166uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 56 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Discharge Resistors
Required See 275.105-10120
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
1.9kg
Factory Pack Quantity
30
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog