RCS-4805-VAR, 5 Amp Output, Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 16 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils):
The RCS-4805 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-4805 comes with 5 Amp integrator..
Included is an 48 inch circumference, 16 inch diameter rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-4805-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Output Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
16 Inch
Coil Circumference
48 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
3500g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
Manual Battery Switch, DPST 2 x 500 Amp 32VDC, Flange Mount 120mm Wide, M10 Terminations, IP67/IEC529
DC battery switches are designed to be placed in between the battery and load. Suitable for any low voltage DC application which requires up to 2kA overload for 1.5 minutes.
Features :
2 Pole Disconnect
Suitable for DC Isolation
Standards :
IEC 60364-7-712
IP65 (Front) IP20 (Terminals)
Specification
Gigavac Part Number
BD9513
Functions
2 Pole DC DPST Disconnect Switch, ON/OFF Red Lever
Nominal Voltage
32VDC
Nominal Current
2 x 500 Amp DC
Rated Impulse Voltage
1.05kV (1 min)
Rated Insulation Voltage
32VDC
Short Circuit Current
2kA (1.5 min), 2.5kA (10s)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
N/A
Standards
IP67/IEC529
Termination
M10
Weight
700g
Enclosure Material
Zytel
Factory Pack Qty
10
Datasheet
Product Datasheet
Fastron Electronics F13FT-2PL 12A 24VDC + F13FT-2Z-C4 Series Din Rail Mount Dual 12 Amp Form C AC/DC Relay, 24VDC Coil, PCB or Socket Mount
Features
2 x 12 Amp @ 250VAC or 30VDC
DIN Rail Mount
Changeover Contact
Compatible with Omron G2R-2-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Suits F13F-2Z-C4 Socket
Specification
Fastron Part Number
F13FT-2PL 12A 24VDC + F13FT-2Z-C4
Switching Type
2 x 30VDC/250VAC C/O DPDT Form C
No. of Pins
8
Approvals
UL,CE
Control Voltage
24VDC
Load Current
2 x 12 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Replacement Relay
F13FT-2PL 12A 24VDC
Replacement Socket
F13F-2Z-C4
LEM DHAB S/134 Series O/L Automotive AC/DC Current Transducer, Multirange
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-50A, and +/-200A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/134
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-50 Amp
Load Current Channel 2 (RMS)
+/-200 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 1.1kHz
Mounting Style
Panel Mount/Cable Mount
Aperture
?22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.7%(37A),1.3%(75A)
Ch2 Accuracy @ 25 Deg C
1.4%(0A),7%(375A),10%(750A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
Schurter 4302.5315 (KFB .25QC 2-P SW 10A), IEC Appliance Inlet C14/M with 1-Stage EMC (RFI), Line Switch 2 Pole
Features
Panel Mount : Screw-on mounting from front side
3 Functions : Appliance Inlet Protection class I, Line Switch 2-pole, EMC Filter 1 Stage
Line filter in standard and medical version
Quick connect terminals 6.3 x 0.8 mm
Characteristics
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
2-stage line filter with increased attenuation
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Medical Version
M80
Specification
Schurter Part Number
4302-5315 (KFB .25QC 2-P SW 10A)
Rated Voltage
250V
Rated Current
10A
Filter Stages
1 Stage Standard Attenuation
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
N/A
Line Switch
2 Pole
Mounting
Panel Mount - Case 50
Material
Nickel Plated Steel
Termination Style
C14 Male to Quick Connects
Weight
120g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Gigavac GV241CAB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 24VDC Coil
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV241CAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
400+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M5)
Load Voltage Range
100 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom PMP4850WP, Phase/Burst control, 240VAC, 50 Amp, Selectable 0-5V,0-10V,4-20mA Input, w/Overvoltage Protection
Features
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
PMP4850WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
50 Amp (rms)
Surge Capability
716Amp (peak)
Special Feature
Proportional Controller + SSR, Overvoltage protection
Mounting Style
Panel Mount
Load Voltage Range
345-530VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
160g
Factory Pack Qty
20
Datasheet
Product Datasheet
PMP24 Installation/Wiring Guide
Equivalent
Crydom PMP2425W or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
LEM DVL 1000 UI Digital Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Multi Range through pin selection
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 1000 UI
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 1000V
Measurement Range
+/- 1500V
Output
4 - 20mA
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Schurter 0090.0001 ASO 10.3x38mm GpV Fast Blow Solar Fuse 1Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0001
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
554 A²/s
Nominal Current (DC)
1 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
0.6W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
FSO Fuse Holders
Schurter 0090.0005 ASO 10.3x38mm GpV Fast Blow Solar Fuse 5Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0005
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
42.6 kA²/s
Nominal Current (DC)
5 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.47W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
FSO Fuse Holders
Schurter 0090.0010 ASO 10.3x38mm GpV Fast Blow Solar Fuse 10Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0010
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
401 kA²/s
Nominal Current (DC)
10 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.76W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
FSO Fuse Holders