CV 4-4000 Digital Voltage Transducer, Vpn = 2828V, +/-15VDC, 10V output, 9kV Isolation
Free Aus Post Shipping for $300 SpendLEM CV 4-4000 Digital Voltage Transducer, Vpn = 2828V, +/-15VDC, 10V output, 9kV Isolation Features Bandwidth DC to 11kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 4-4000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2828V Measurement Range +/- 4000V Output 10V @Vp(max) Isolation 9 kV Bandwidth DC-11 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4 Datasheet Product Datasheet
-
FF400R33KF2C, IGBT Inverter, 400Amp, 3300V
Free Aus Post Shipping for $300 SpendInfineon FF400R33KF2C, IGBT Inverter, 400Amp, 3300V Features IGBT for High Frequency Inverter Pressure Contact Technology Electrically insulated base plate Industrial standard package Medium Switching Speed 6000V Isolation 73mm Base Width Applications Frequency Converter Deep Cycle Applications Controlled Rectifiers Soft start AC motor control High Frequency Inverter Drives Specification Infineon Part Number FF400R33KF2C Vces 3300V Transistor Configuration Dual IGBT Module (Half Bridge) Ic(nom) @ 80 Deg C 400 Amp Package Size W:130mm L:160mm D:38mm V(isol) 6 kV Vf @ 25 Deg C 2.8 - 3.5V Tj(max) 150°C Td(on) @ 25 Deg C 0.28uS Td(off) @ 25 Deg C 1.55uS I(ces) @ 25 Deg C 5mA Rcc 0.37mOhm Terminals M5 Screw Hole Centres 114 x 124mm(M6) Gate Terminals M4 R th(j-c) 51°C/W R th(c-h) 36°C/W Weight 1100g Mounting Torque 5 Nm (4 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Infineon Headquarters Germany Datasheet Product Datasheet Alternatives Dynex 400 Amp Equivalent Dynex 500 Amp Equivalent
-
DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols, PTB Approved for Billing Purposes
Free Aus Post Shipping for $300 SpendDCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols. PTB Germany Approved, or MID Approved for Billing 0-400/600 Amp Shunt Measurement Options (Included) Bi-Directional DC Measurement Voltage Measurement Range 150V to 1150V Backlit LCD 12VDC to 24VDC Supply Voltage Meter Operating Temperature -25°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max IP Enabled with DHCP 12 - 24VDC Supply Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Graphic LCD with illumination Specification LEM Part Number DCBM400, DCBM600 Functions DC Energy Meter Supply Voltage 12-24VDC Nominal Measurement Range 150VDC to 1000VDC Maximum Measurement Range 150 - 1150VDC Nominal Current Input Shunt Provided IP Conficguration Fixed or DHCP Accuracy Class B Mounting Din Rail Mount Real Time Clock NTP Time Sync over HTTPS/REST Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms HTTPS/REST, Ethernet IP, OCMF/SAFE Signed Data Weight 5/6kg Certification PTB, VDE-AR-E-2418-3-100 Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C ) Datasheet Product Datasheet Leaflet
-
Thyro-A-1A-230-170-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 170Amp 230VAC +10%/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Thyro-A-1A-230-170-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 170Amp 230VAC +10%/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes Features Optional Profinet, Profibus, Ethernet, Modbus Comms 230VAC +10%/-57%, Voltage Control, +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-1A-230-170-H-RL3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC +10%/-57%, Voltage Control, +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,426.60
$2,863.39 inclGST -
Thyro-A-1A-230-130-H-RLP3, Thyro-A-1A-Series Single Phase SCR Controller 130Amp 230VAC +10%/-57%, Voltage Control, Current Feedback, Power Control Options, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Thyro-A-1A-230-130-H-RLP3, Thyro-A-1A-Series Single Phase SCR Controller 130Amp 230VAC +10%/-57%, Voltage Control, Current Feedback, Power Control Options, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes Features Optional Profinet, Profibus, Ethernet, Modbus Comms 230VAC +10%/-57%, Voltage Control, +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-1A-230-130-H-RLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC +10%/-57%, Voltage Control, +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,599.30
$3,067.17 inclGST -
Thyro-A-2A-400-130-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 130Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options
Advanced Energy Thyro-A-2A-400-130-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 130Amp 400VAC +10/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-2A-400-130-HRLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$4,107.40
$4,846.73 inclGST -
DCR3060V24, Thyristor(SCR) 2320 Amp, 2400V 111/26, w/ 400mm Hard Soldered Gate Leads
Free Aus Post Shipping for $300 SpendDynex DCR3060V24, Thyristor(SCR) 2320 Amp, 2400V 111/26, w/ 400mm Hard Soldered Gate Leads Features Very low forward voltage drop Very low leakage current International standard package 111/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Dynex IXYS Part Number DCR3060V24 Vrrm 2400V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 85 Deg C 2320 Amp Package Size ø111 x 26mm Itsm 45 kA VF(to) 0.9V Tj(max) 125°C rF 0.137mΩ Gate Terminals Hard wired Gate leads R th(j-c) (double sided cooled 180°sin) 0.01°C/W R th(c-h) (double sided cooled) 0.003°C/W Weight 1.2kg Clamping Force 50 - 62kN Factory Pack Qty 12 Certification ROHS Dynex Headquarters UK Datasheet Product Datasheet Alternatives N3533ZC220 Dynex 2022 Shorform Catalogue Heatsink Heatsink Profiles
-
LT 4000-S/SP24 C/L Hall Effect Current Sensor, Ipn = 3300 Amp, Isn = 660mA, +/-24VDC Supply, Busbar, X = 0.5%, panel mount
Heavy Item - No Free ShippingLEM LT 4000-S/SP24 C/L Hall Effect Current Sensor, Ipn = 3300 Amp, Isn = 660mA, +/-24VDC Supply, Busbar, X = 0.5%, panel mount Features Bipolar and insulated current measurement up tp 6000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 4000-S/SP24 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 3300 Amp Measurement Range +/- 6000 Amp Output 660 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style M5 threaded studs Unit Weight 12.1kg Factory Pack Quantity 1 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DV 4200/SP4, Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation
LEM DV 4200/SP4, Digital Voltage Transducer, Vpn = 4200V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DV 4200/SP4 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 4200V Measurement Range +/- 6000V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,642.00
$1,937.56 inclGST -
HX460CFA, Contactor SPST-NO 1000 AMP, 1500VDC, 24VDC Coil, Molex 5-pin Connector 39-01-4050, lead length 28 cm (11 in), with SPDT Auxiliary Contact 5000 Cycles, IP67, IP69
Heavy Item - No Free ShippingGigavac HX460CFA, Contactor SPST-NO 1000 AMP, 1500VDC, 24VDC Coil, Molex 5-pin Connector 39-01-4050, lead length 28 cm (11 in), with SPDT Auxiliary Contact 5000 Cycles, IP67, IP69 Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69 SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Specification Gigavac Part Number HX460CFA Main Contact Type SPST-NO Auxiliary Contact Type SPDT 1NO+1NC Coil Voltage 24VDC Load Current 1000 Amp Mechanical Life @ 0 Amp 100,000 Operations Dielectric at Sea Level (leakage <1mA) 5.375kV rms Control Input Terminals Molex 5-pin Connector 39-01-4050, lead length 28 cm (11 in) Aux Contact Terminals Molex 5-pin Connector 39-01-4050, lead length 28 cm (11 in) Special Feature N/A Mounting Style Panel Mount (M6) Load Voltage Range 1500VDC Standards UL1604, IP67, IP69, SAE J1171, ISO8846 Termination Style M12 Unit Weight 4.17kg Factory Pack Qty 1 Datasheet Product Datasheet
-
DK 200 B420 B, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 4-20mA bipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 200 B420 B, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 4-20mA bipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 100, 150, 200 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Bipolar Measurement 4-20mA analogue output Busbar or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 200 B420 B Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 100,150,200 Amp Selectable Response Time < 100ms Output 4-20mA Bipolar Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DCM650-H, Class B, DIN Rail Mount, 1000VDC, with 550 Amp internal Shunt, 3 x RS485 Modbus RTU Ports, PTB Approved for Billing Purposes
DCM650-H, Class B, DIN Rail Mount, 1000VDC, with 550 Amp internal Shunt, 3 x RS485 Modbus RTU Ports, PTB Approved for Billing Purposes 0-650 Amp Shunt Measurement Bi-Directional DC Measurement Voltage Measurement Range 150V to 1000V Backlit LCD 9-40VDC Aux Supply Voltage Meter Operating Temperature -25°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Dot Matrix LCD with illumination Specification Eastron Part Number DCM650-H Functions DC Energy Meter Supply Voltage 9-40VDC Nominal Measurement Range 150VDC to 1000VDC Maximum Measurement Range 150 - 1000VDC Nominal Current Input Shunt Provided IP Conficguration Fixed or DHCP Accuracy Class B Mounting Din Rail Mount Real Time Clock N/A Dimensions 103 x 104 x 64mm Pulse Output Optional Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms 3 x RS485 Modbus RTU 4800-115200bps (192000bps default) Weight 5/6kg Certification PTB, VDE-AR-E-2418-3-100 Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C ) Datasheet Product Datasheet
$1,495.00
$1,764.10 inclGST