AT-DAO(0-10)-A-1, DC Current Transducer, 0-10Amp DC, 100-240VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-DAO(0-10)-A-1
Control Output
4-20mA
Input
0-10 Amp DC
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Current Transducer, AT-AA8-A-4, AC Current Transducer, Average RMS, 5 Amps, 22-60VAC/DC Aux, 0-10V output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA8-A-4
Control Output
0-10V Average RMS
Input
0-5 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Current Transducer, AT-AAO(0-1)-A-1, AC Current Transducer, 1 Amp Average RMS, 100-240VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AAO(0-1)-A-1
Control Output
4-20mA Average RMS
Input
0-1 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics SCT-F16-10, 10A/0.333V Measurement Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-10
Technology
Split Core AC Current Transformer
Ratio
10/0.333V
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
25Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FGIR-2511-230VAC, Two Pole 1 x SPST NO, Configuration_SPST (1 x NC) Bistable Relay with Manual Override 240VAC 25 Amp, 230VAC Control Voltage, 50/60Hz
Features
25 Amp (rms) @ 240VAC
DIN Rail Mount
Slim package
CCC Compliant
IP20
Specification
Fastron Part Number
FGIR-2511-230VAC
Switching Type
1 x SPST NO, Configuration_SPST (1 x NC)
Approvals
CE
Coil Voltage
230VAC
Load Rating
25 Amp
Special Feature
Mounting Style
DIN Rail Mount
Load Voltage Range
240VAC 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Datasheet
Fastron FPC1-63-40C-230VAC/DC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 63 Amp 50/60Hz, 230VAC/DC Coil Voltage, Hum Free
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
FPC1-63-40C-230VAC/DC
Switching Type
4 x SPST NO
Approvals
CE
Coil Voltage
230VAC, 50/60Hz
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC, 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Auxiliary Contacts Selection Guide
Fastron FPC1-25-11C-230VAC, Two Pole 1 x SPST NO, Configuration_SPST (1 x NC) Modular Contactor 230VAC 25 Amp, 230VAC/220VDC Coil Voltage, 50/60Hz, Hum Free
Features
25 Amp (rms) @ 230VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
FPC1-25-11C-230VAC
Switching Type
1 x SPST NO, Configuration_SPST (1 x NC)
Approvals
CE
Coil Voltage
230VAC
Load Rating
25 Amp
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
230VAC 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Datasheet
Auxiliary Contacts Selection Guide
Westcode - IXYS, B0800YC180, Thyristor (SCR) Capsule 456Amp, 1800V, 41/14
Features
Very low forward voltage drop
Very low leakage current
International standard package
41/14 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Controlled Rectifiers
AC Switch
Battery Chargers
Phase Controllers
Water Cooled AC switches
Power Factor Correction
Specification
Westcode-IXYS Part Number
B0800YC180
Vrrm
1800V
SCR Configuration
Thyristor(SCR) Capsule PUK
IF(av) @ 85 Deg C
545 Amp
Package Size
ø41 x 14mm
Itsm
7.5 kA
Gate Terminals
Faston 4.8 x 0.8mm & 2.8 x 0.8mm
Weight
90g
Factory Pack Qty
12
Certification
ROHS
IXYS Headquarters
USA
Datasheet
Product Datasheet
Heatsink
Heatsink Profiles
Westcode-IXYS-Littlefuse B1115LC180, Thyristor(SCR) PUK 756 Amp, 1800V, 58/26, drop in replacement for N1114LC180 or N1114LC160
Features
Very low forward voltage drop
Very low leakage current
International standard package
58/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Westcode Part Number
B1115LC180
Vrrm
1800V
Diode Configuration
Thyristor Capsule (PUK)
IF(av) @ 84 Deg C
820 Amp
Package Size
ø58 x 26mm
Itsm
12.7 kA
Gate Terminals
Faston
Weight
340g
Factory Pack Qty
6
Certification
ROHS
Westcode Headquarters
UK
Datasheet
Product Datasheet
Alternatives
T720N16TOF
Heatsink
Heatsink Profiles
Westcode-IXYS-Littlefuse B1815NC160, Thyristor(SCR) PUK, 1225Amp, 1600V, 74/26, Replaces N1802NC160
Features
Very low forward voltage drop
Very low leakage current
International standard package
74/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Westcode-IXYS Part Number
B1815NC160
Vrrm
1600V
Diode Configuration
Thyristor Capsule (PUK)
IF(av) @ 60 Deg C
1225 Amp
Package Size
ø74 x 26mm
Itsm
29.6 kA
Tj(max)
125°C
Gate Terminals
Faston
Weight
510g
Factory Pack Qty
6
Certification
ROHS
IXYS Headquarters
USA
Datasheet
Product Datasheet
Alternatives
T1190N16TOF VT
SKT1200/18E
N1718NC200
Contact Us for Possible Replacement
Heatsink
Heatsink Profiles
Fastron FC5-M-1U-1-G-4-C, PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, 0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-M-1U-1-G-4-C
Control Output
0-10V
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 72x72mm with SSR/Relay output)
Comms
RS485 Modbus RTU 38400 Max Baud Rate
Mounting Style
72x72mm Panel Mount
Supply Voltage
24VDC +/-15%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron FC5-M-W-2-G-2 PID Controller, 100-240VAC with 2 Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-M-W-2-G-2
Control Output
SSR/Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ SSR 12VDC @20mA
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 Alarms standard
Comms
Optional (Modbus RTU 38400 Max Baud Rate)
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol