Search results for "tg�� banonpi 24�üҾױ������� �ٳ������ɳ����� ���������ʼ����ں���Ҿ״��� ���Ȱ����� ���������ɸŸ�"
-
FGM6S-3P-250H 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=50kA 160 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-3P-250H 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 50kA 160 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-250H 160A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 160 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
CV 3-1000 Digital Voltage Transducer Flux Gate, Vpn = 700V, +/-15VDC, 10V output, 6kV Isolation
Free Aus Post Shipping for $300 SpendLEM CV 3-1000 Digital Voltage Transducer Flux Gate, Vpn = 700V, +/-15VDC, 10V output, 6kV Isolation Features Bandwidth DC to 500kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 3-1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 700V Measurement Range +/- 1000V Output 10V @Vp(max) Isolation 6 kV Bandwidth DC-500 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4 Datasheet Product Datasheet
-
IKD225-11-230VAC, Two Pole 1 x SPST NO, Configuration_SPST (1 x NC) Modular Contactor 240VAC 25 Amp, 230VAC/220VDC Control Voltage, 40-500Hz, Hum Free
Free Aus Post Shipping for $300 SpendIskra IKD225-11-230VAC, Two Pole 1 x SPST NO, Configuration_SPST (1 x NC) Modular Contactor 240VAC 25 Amp, 230VAC/220VDC Control Voltage, 40-500Hz, Hum Free, Can Replace MC-25-24-1NO1NC Features 25 Amp (rms) @ 240VAC DIN Rail Mount Changeover Contact Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number IKD225-11-230VAC Switching Type 1 x SPST NO, Configuration_SPST (1 x NC) Approvals CE Coil Voltage 230/240VAC/220VDC Load Rating 25 Amp Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 240VAC Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Contactor Datasheet
-
TGD-4PL C 50-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 50 Amp, 10kA, 1000VDC
TRENT TGD-4PL C 50-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 50 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 50-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 50 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$59.50
$70.21 inclGST -
BH-15-2-24, Split Core Hall Effect DC Current Transducer, +/-15 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-15-2-24, Split Core Hall Effect DC Current Transducer, +/-15 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-25 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-25-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-25 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 25Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$425.00
$501.50 inclGST -
FGM6SM-3P-250H 200A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=50kA 200 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6SM-3P-250H 200A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 50kA 200 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-3P-250H 200A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6SM-4P-250H 160A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=50kA 160 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6SM-4P-250H 160A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 50kA 160 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-250H 160A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 160 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
BLR-CM12R-MB, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025)
BLR-CM12R-MB, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025) Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio Specification Beluk Part Number BLR-CM12R-MB Function Reactive Power Correction Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger Optional 3 x CT Measurement Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 Modbus RTU Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)
$1,549.75
$1,828.71 inclGST -
FGM6SM-4P-160M 100A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=36kA 100 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6SM-4P-160M 100A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 36kA 100 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-160M 100A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 100 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6S-3P-160M 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 125 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-3P-160M 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 125 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-160M 125A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 125 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6S-3P-160M 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 160 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-3P-160M 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 160 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-160M 160A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 160 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6S-3P-160H 80A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=50kA 40 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-3P-160H 80A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 50kA 80 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-160H 80A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 80 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet