Search results for "tg@tetherzon~"
-
HO 6-P, O/L Hall Effect Current Sensor, 6 Amp, 8 x 8mm Aperture, 5VDC Supply, PCB Mount
LEM HO 6-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Fixed offset & sensitivity Voltage output Single supply +5 V Overcurrent detect 2.63 × IPN (peak value) Galvanic separation between primary and secondary circuit Low power consumption For PCB mounting 8x8mm Aperture Advantages Small size and space saving Same package for wide primary current range Creepage / clearance > 8 mm High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HO 6-P Technology Open Loop Hall Effect Aperture 8 x 8mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 6 Amp Measurement Range +/-20 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-250 kHz Mounting Style Busbar Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 10g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$12.55
$14.81 inclGST -
HO 8-NSM-0000, O/L Hall Effect Current Sensor, 8 Amp, No Aperture, Surface Mount
LEM HO 8-NSM-0000 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Multirange through PCB routing Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Compact design for THT PCB mounting Factory calibrated Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 8-NSM-0000 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 8 Amp Measurement Range +/-20 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-250 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Surface Mount Unit Weight 34g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$11.35
$13.39 inclGST -
Thyro S 3S Series Three Phase SCR Controller 16 - 1500Amp 400VAC +10/-15%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes
Advanced Energy Thyro S 3S Series Three Phase SCR Power Controller, 16-1500Amp, 400VAC, Phase(VAR), Burst(TAKT), SWITCH Operating Modes. Compatible Replacement for Eurotherm Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module  Specification Advanced Energy Part Number Thyro S 3S 400VAC or Thyro S 3S 500VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1  Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,154.91 - $10,967.22
-
MTC250-16-216F3E, 250 Amp, 1600V, Dual Thyristor Module
Techsem MTC250-16-216F3E, 250 Amp, 1600V, Dual Thyristor Module Features Package with DCB ceramic Electrically insulated base plate Improved temperature and power cycling Planar passivated chips Very low forward voltage drop Very low leakage current 3600V Isolation Industrial standard package 20mm Base Width Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers For single and three phase bridge configurations Field supply for DC motors Input rectifiers for PWM inverter Specification Techsem Part Number MTC250-16-216F3E Vrrm 1600V Diode Configuration Dual Thyristor Module IF(av) @ 85 Deg C 250 Amp Package Size TO-240AA W:20mm L:93mm D:30mm Itsm 6 kA VF(to) 0.81V Tj(max) 125°C rF 1.23mΩ Terminals M5 Screw Hole Centres 80mm (M6) Gate Trigger Current N/A R th(j-c) 0.13°C/W R th(c-h) 0.08°C/W Weight 150g Mounting Torque 2.5 Nm (5 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Techsem Headquarters Techsem  Datasheet Product Datasheet Alternatives See MCMA260P1600YA for IXYS Alternative
$115.00
$135.70 inclGST -
Thyro S 1S Series Single Phase SCR Controller 16 - 1500Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Advanced Energy Thyro S 1S Series Single Phase SCR Power Controller, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), SWITCH Operating Modes. Compatible Replacement for Erutotherm Features Optional Profinet,Profibus,Ethernet,Modbus Comms 500VAC +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro S 1S 500VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 500VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1  Technical Docs Brochure User Manual Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$932.50 - $2,882.00
-
Thyro S 2S Series 2 Leg 3 Phase Solid State Contactor 16 - 1500Amp 400VAC +10/-15% Burst(TAKT) Fire Mode, Economical Firing Mode
Advanced Energy Thyro S 2S Series 2 Leg 3 Phase Solid State Contactor, Burst(TAKT)Firing Mode Only. Compatible Replacement for Eurotherm Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module  Specification Advanced Energy Part Number Thyro S 2S 400VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1  Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$1,266.46 - $7,229.20
-
FTA-400-420B-24, Hall Effect DC Current Transducer, +/-400 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-400-420B-24, Hall Effect DC Current Transducer, +/-400 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-400 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-400A ~+/-400A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-400-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-400 Amp Response Time < 10uS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 4 Pin Unit Weight 300g Factory Pack Qty 6  Datasheet Product Datasheet
$285.00
$336.30 inclGST -
LT-CG-S/D-005-A0020-12-L, Room Air Temperature Sensor and Transmitter, 4-20mA output, -40 to 80 Deg C
Fastron LT-CG-S/D-005-A0020-12-L, Room Air Temperature Sensor and Transmitter, 4-20mA output, -40 to 80 Deg C 4-20mA Output 2 Wire Temp Measurement for -40 to 80 Deg C Max 24VDC Supply Specification Fastron Part Number LT-CG-S/D-005-A0020-12-L Sensor Type NTC No of Wires 2 Output 4-20mA Dimensions 86 x 41 x 116mm Approvals CE, ROHS Cable length N/A Temperature Range -40 to 80 Deg C Mounting Style Panel Mount Weight 150g Factory Pack Qty 1 Datasheet Datasheet
$109.00
$128.62 inclGST -
THST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-1000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6  Datasheet Product Datasheet
-
THST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-850 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-850-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-850 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6  Datasheet Product Datasheet
-
THST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-1500-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6  Datasheet Product Datasheet
-
FTA-400-420-24, Hall Effect DC Current Transducer, 0-400 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-400-420-24, Hall Effect DC Current Transducer, 0-400 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-400 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-400A ~0-400A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-400-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-400 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 4 Pin Unit Weight 300g Factory Pack Qty 6  Datasheet Product Datasheet
$285.00
$336.30 inclGST