TCD-L-2-K COOLING Temp Controller, 96x96mm 230VAC, C/O Relay output, Type K Input. Encoder Control,amp; Digital Display, 0-999 Deg C
Pushbutton Encoder Setpoint
3-digit display (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TCD-L-2-K
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Type K Thermocouple
Control Mode
Cooling ON/OFF Control
Control Range
0- 999 Deg C
Mounting Style
96x96mm Panel Mount
Supply Voltage
230VAC
Termination Style
Screw
Sampling Time
50ms
Weight
270g
Factory Pack Qty
1
Datasheet
TCD/TCR/FC5 Datasheet
TCD/TCR User Manual
Fastron TTH-32-SA2-1, Relative Humidity Sensor and Transmitter, 300 x 6mm w/1m Cable
1 x 4-20mA Output 2 Wire
Humidity Measurement for RH 0 to 100 %
Long Term Stability <2% RH per year
300 x 6mm with 1M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Thin Film Capacitor Sensing Elements
Specification
Fastron Part Number
TTH-32-SA2-1
Sensor Type
Thin Film Capacitor (Humidity)
No of Wires
2
Shaft Length
300mm
Shaft Thickness
6mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram
F22-271R, 22mm Momentary Pushbutton Switch Metal with RED Ring Illumination, 1xNO 1xNC, 3Amp (Nominal) 5 Amp (Max) @ 250VAC or 24VDC, 24VDC Illumination Supply, 0.05 Million Ops
Description
Pushbutton switch available in version Standard, Illuminated, with Point Illumination, 1xNO 1xNC, Lettering, varnished in different colours
Assembly by mounting with nut
Pin connections, Pins with Soldering Aid or Clip for Pins
Characteristics
Housing and actuator material types: zinc die-cast with nickel plating or stainless steel
Wide range of materials, colours, lettering, colours of illumination - Switching voltage max. 250VAC 30VDC, switching current max. 12 Amp
24VDC Illumination Supply Voltage
Zinc die-cast for housing and actuator For indoor use, no Illumination, 1xNO 1xNC, no lettering
Stainless Steel for actuator Optional point illumination and laser lettering with standard or customer-specific symbols
Stainless Steel for housing and actuator for use in harsh environments outdoors (see technical data)
Tamper Proof suitable for public spaces
Specification
Fastron Electronics Part Number
F22-271R
Switch Size
20 x 22mm
Nominal Voltage
250VAC/DC
Rated Power
750W
Switch Type
Momentary 1xNO 1xNC
Illumination voltage
24VDC @ 10mA
Illumination type
RED RING
Nominal Current (AC/DC)
3 Amp @240VAC/24VDC
Contact Resistance ON/OFF
<100m Ohm
Dimensions
ø22 x 14.6mm
Operating Temperature Range
-20°C / 85°C
Termination
Faston/Solder Pins
IP Protection Rating
(IP 67 with Oring) IP 64 (IP40 switching circuit)
Unit Weight
40g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fastron Electronics GTD-DA6-A-11, Signal Conditioner/Voltage Transducer, 4-20mA input, 100-240VAC/DC aux, Dual 4-20mA outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DA6-A-11
Conditioned Output
2 x 4-20mA
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-LL2-D-4, Signal Transmitter/Conditioner, Load Cell, 2mV/V EX.5V input, 0-10V output, 22-60VAC/DC supply
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-LL2-D-4
Control Output
0-10V
Input
2mV/V EX.5V
Over Range
N/A
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Hobut CT 132 G5 120/5 Amp CT 1VA Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Hobut Part Number
CT 132 G5 120/5
Technology
AC Current Transformer
Ratio
120/5
Aperture Size
⌀ 21mm
VA Rating
1VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
120Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron TTH-32-SA3-3, Relative Humidity Sensor and Transmitter, 500 x 6mm w/3M Cable
1 x 4-20mA Output 2 Wire
Humidity Measurement for RH 0 to 100 %
Long Term Stability <2% RH per year
300 x 6mm with 3M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Thin Film Capacitor Sensing Elements
Specification
Fastron Part Number
TTH-32-SA3-3
Sensor Type
Thin Film Capacitor (Humidity)
No of Wires
2
Shaft Length
500mm
Shaft Thickness
6mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram
Crydom DRA-CN240A24, Slimline Relay & Socket, 15-30VDC Coil, 2 Amp 24-280VAC Load
Features
Output 2Amp @ 250VAC
15-30VDC Control input
DIN Rail Mount
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
DRA-CN240A24
Switching Type
250VAC 2 Amp Load SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
15-30VDC
Load Current
2 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
250VAC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Datasheet
Relay Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket
RODN604025, Steel Enclosure, 600mmH x400mmW x 250mmD, IP66, RAL 7035 Gray 1.5mm Galvanised Steel
Features
Injected Polyurethane Sealing gasket
3 x M20 cable glands
4pcs Wall Mounts and dynabolts included
Lockable Door via Key
RAL7035 GREY AS3000/AS3100 Compliant
IP66
Specification
Fastron Part Number
RODN604025
Function
Steel Water Proof Enclosure
Configuration
Enclosure with Hinged Door, Key Lock, 4 Mounting Clips, DYnabolts, and Cable Glands
Termination Style
Screw
Dimensions
H:600 x W:400 x D:250mm
Weight
15.6kg
Certification
AS 3000
AS 3100
Factory Pack Qty
1
Material of housing
1.5mm Galvanised Steel Painted RAL 7035
Enclosure protection
IP66
Operating Temperature
-20...55 °C
Datasheet
Datasheet
Fastron GPH10048ZD3, Solid State Contactor SSR, Single Phase 5-24VDC Control, 100Amp 70-480VAC Load, Din Rail Mount
Ratings from 10A to 100 Amp @ 70-480 VAC
Contactor Style for retrofit
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
IP20
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Spec
Fastron Part Number
GPH10048ZD3
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
5-24VDC
Load Current (single unit)
92 Amp (rms) @ 20 Deg C Ambient, 68 Amp (rms) @ 40 Deg C Ambient
Surge Capability
1600 Amp (peak)
Special Feature
Contactor Style IP20 Terminals
Mounting Style
DIN Rail Mount
Load Voltage Range
70 - 480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron TC5-W-W-2-A-2 PID Controller 100-240VAC, with 2 3 Amp Relay Alarms, 4-20mA Input, 96x48mm, Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-W-W-2-A-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ 12VDC @20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 96x48mm with SSR/Relay output)
Mounting Style
96x48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Fastron TTH-32-DB-1, Relative Humidity Sensor and Transmitter, 190 x 18-19mm w/1m Cable, Can replace GEFRAN TRANSMICOR T211
1 x 4-20mA Output 2 Wire
Humidity Measurement for RH 0 to 100 %
Long Term Stability <2% RH per year
190 x 18mm with 1M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Thin Film Capacitor Sensing Elements
Specification
Fastron Part Number
TTH-32-DB-1
Sensor Type
Thin Film Capacitor (Humidity)
No of Wires
2
Shaft Length
190mm
Shaft Thickness
18-19mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram