H-10-2-24, Split Core Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-10 Amp DC, 4-20mA Unipolar Output
Features
⌀31mm Aperture
Split Core
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
H-10-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-10 Amp
Response Time
< 200mS
Output
Unipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
SKD 30/16A1, 3 Phase Diode rectifier Bridge, 30 Amp, 1600V Replaces PSD35T/16
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Semikron Part Number
SKD 30/16A1
AC Line voltage
533V
Device Configuration
Three Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
35 Amp
Package Size
W:55mm L:45mm D:24mm
Itsm
370 A
VF(to)
0.85V
Tj(max)
150°C
rF
12mΩ
Terminals
M4 (1.5Nm)
Hole Centres
45mm (M4)
Gate Terminals
N/A
R th(j-c)
2.8°C/W
R th(c-h)
0.6°C/W
Weight
110g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
Semikron Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See PSD55T/16 or PSD51/18 for higher rated equivalent
Fastron Electronics SCT-F16-10-1A, 10/1Amp Measurement, Class 1 Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-10-1A
Technology
Split Core AC Current Transformer
Ratio
10/1A
Aperture Size
ø 15 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
10Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FPC1-63-40C-230VAC/DC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 63 Amp 50/60Hz, 230VAC/DC Coil Voltage, Hum Free
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
FPC1-63-40C-230VAC/DC
Switching Type
4 x SPST NO
Approvals
CE
Coil Voltage
230VAC, 50/60Hz
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC, 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Auxiliary Contacts Selection Guide
Fastron Electronics FEFC203-200-T, 2 Stage EMI (RFI) Input [Inverter] Output [NON Inverter] Sine Wave Filter for 3-phase 3 wire systems, 200 Amp, 400VAC
Features
Suitable alternative to Schaffner FN3258(Input) or FN5020(Output) Series
3 phase Input [Inverter] Output [NON Inverter] Sine Wave Filter with standard attenuation
400VAC +10%
Applications
Input of VSD Drives or Controlled Rectifiers
Diesel Generator Output
CNC Machinese
Elevators
Power Supplies
For Industrial Applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Fastron Part Number
FEFC203-200-T
Rated Voltage
400V
Rated Current
200A
Filter Stages
2 Stage (3 Phase 3 wire)
Operating Temperature
-25°C to 85°C
Filter Type
Excellent Attenuation for Sine Wave Output, Moderate Attenuation for input Line Filtering
Leakage Current
N/A
Mounting
Panel Mount - Case 32-7
Material
Metal
Termination Style
Screw
Weight
4.5kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
CE, ROHS
Yes
Datasheet
Product Datasheet
Fastron Electronics FEFA301-20-M, 3 Stage EMC (RFI) Line Filter, 20 Amp 250VAC, Very High Symmetrical and Asymmetrical Attenuation
Features
Line filter in standard and medical version
2-stage - high attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Fastron Part Number
FEFA301-20-M
Rated Voltage
250V
Rated Current
20A
Filter Stages
3 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.5mA
Mounting
Panel Mount - Case FF
Material
Metal
Termination Style
Screw
Weight
800g
Factory Pack Qty
4
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Fastron FC5-M-W-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-M-W-1-G-2-C
Control Output
SSR/Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ SSR 12VDC @20mA
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 72x72mm with SSR/Relay output)
Comms
RS485 Modbus RTU 38400 Max Baud Rate
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron FC5-M-W-1-G-4 PID Controller, 24VDC with 1 Alarm, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-M-W-2-G-4
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ SSR 12VDC 40mA
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 Alarm, standard
Comms
Optional (Modbus RTU 38400 Max Baud Rate)
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron Electronics GT-AV(0-500)-A-1, AC Voltage Transducer, 0-500V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-500)-A-1
Control Output
4-20mA Average RMS
Input
0-500VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-AV(0-500)-D-1, AC Voltage Transducer, 0-500V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-500)-D-1
Control Output
4-20mA Average RMS
Input
0-500VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics FWBV414H29-300AC-420, AC Voltage Transducer, 0-300V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request), Low Profile
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 42 x 50 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
FWBV414H29-300AC-420
Control Output
4-20mA Average RMS
Input
0-300VAC, 50/60Hz (25Hz - 1kHz Available on Request)
Over Range
x 1.2 (Continuous)
Operating Temperature
-25 - 70°C
Load Voltage
100-240VAC/DC
Termination Style
Screw
Mounting Style
DIN Rail Mount
Dimensions
H:102 x W:42 x D:50mm
Standards
EN50022
Case Material
PC - UL 94 V0
Weight
250g
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM HAX 1500-S/SP18, O/L Current Transducer, 1500 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output, SP18 = Electrolube, UR5604 A+B Potting
Features
Bandwidth DC to 25kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 100 to 2500 A in one package.
Up to 5500 A measurement range
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
HAX 1500-S/SP18
Technology
Open Loop Hall Effect
Aperture
64 x 21mm Square
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
1500 Amp
Measurement Range
+/-4500 Amp
Overload Rating
+/-30000 At
Output
+/-4 V
Isolation
4.4 kV
Bandwidth
DC-25 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
450g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition