Fastron Electronics SCT-F24-100, 100 Amp, 0.333v Class 1 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-100
Technology
Split Core AC Current Transformer
Ratio
100/0.333v
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FC5-S-R-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x48mm,Relay Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-R-2-T/R-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type,K,E,J,N,T,S,R,B, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
DCBT-050-24-420, Hall Effect DC Current Transducer, +/-50 Amp DC, 4-20mA bipolar output, 24VDC supply, 20mm Aperture
Compact and versatile Split Core DC current sensor, +/-50 Amp DC, 4-20 mA Bipolar Output
Features
⌀20mm Aperture
DC Bipolar Measurement
4-20mA analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DCBT-050-24-420
Technology
DC Hall Effect Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-50 Amp
Response Time
< 1uS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Molex 4 Pin
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron FRTD-Transmitter-0-100-420-24, Pt100, 4-20mA Transmitter, 0 to 100 Deg C, 24VDC Supply
Class A Accuracy
Steel Insulated Cable
Low Long Term Drift
Rated for 0 to 220 Deg C Max
Spring Cable Connection
60mm Jaw Clip
Specification
Fastron Part Number
FRTD-Transmitter-0-100-420-24
Sensor Type
Pt100 to 4-20mA Transmitter
No of Wires
3
Shaft Length
N/A
Shaft Thickness
N/A
Accuracy
Class B
Temperature Range
0 to 400 Deg C
Span/ Zero Adjustment
YES
Weight
50g
Factory Pack Qty
1
WCP195x23/290/G DIS Water Cooler Block for 140mm Isolated Modules including IGBT & Diodes and SCR's
8400W Maximum dissipation
20 L/min
112 Deg C maximum cold plate temp
Outlet coolant temperature 71.5 Deg C
Thermal Rating
Refer to datasheet
Datasheet
Product Datasheet
Thermal Analysis
Replacement for Omron E5C2-R20KAC100-240 0-200, DIN-sized (48 x 48 mm) Temperature Controller with Analogue Dial Setting, Type K Thermocouple 0-200°C, 240VAC, 50/60Hz
Product Datasheet
Fastron Electronics SCT-F16-25-1A, 1 Amp Output, 25Amp measurement Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-25-1A
Technology
Split Core AC Current Transformer
Ratio
25/1A
Aperture Size
ø 15 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
25Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Advanced Energy Thyro-A-1A-500-100-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 100Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Features
Optional Profinet,Profibus,Ethernet,Modbus Comms
500VAC +10/-57% Voltage, Current or Power Control
Built in Fuse
Smallest footprint on the market
Single Phase Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
Quick TAKT Mode (QTM), VT Mode (on request)
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
Potentiometer Adjustment
USB Configuration/Bias Setting
Synchronisation Function (dASM Module Recommended)
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
AC Soft Starter (Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-1A-500-100-H-RL3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
500VAC +10/-15% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 30kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Advanced Energy Thyro-A-3A-400-100-H-RL3, Three Phase SCR Controller 100 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustments
Synchronisation Function for Multiple TAKT Sync
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (VAR Mode Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-3A-400-100-H-RL3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Three Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-57% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Fastron Electronics SCT-F16-20-5A-CL5, 5 Amp, 20Amp measurement Split Core CT's CLASS 5 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-20-5A-CL5
Technology
Split Core AC Current Transformer
Ratio
20/5 Amp
Aperture Size
ø 16 mm
VA Rating
N/A
Accuracy Class
Class 2
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
20Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
DC-0-50-420B-1.0, Hall Effect DC Current Transducer, 0-50 Amp DC, 4-20mA Bipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-50 Amp DC, 4-20 mA Bipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Bipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-50-420B-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-50 Amp
Response Time
< 1uS
Output
Bipolar 4-20mA
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
TPR-3SL040H-F, SCR Phase/Burst Controller Fan Cooled, 400VAC 3 Wire (400V L-L, 230V L-N), 3 Phase, 1-5V/4-20/0-20mA/POT Input, with In built Fuses, 32 Amps per Phase @ 50 Deg C
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
3 Phase, or Single Phase, Angle/Burst Controller
4-20mA/1-5V/10K POT Input Proportional Control
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium/Plastic Frame
Removable Cover
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
TPR-3SL040H-F
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA (Default), 1-5V, 10K POT)
Load Current
32 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
2 x NO Relay Contact
Comms
Optional RS485 Modbus RTU
Special Feature
Internal Fuse
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
100-240VAC +/-10%
Delay on Start
NA
Soft Start
Programmable from 0 to 60 seconds
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual