Iskra Doo MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage
Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc.
Features :
Magnetic and Thermal releases
< 50mS Trip Delay Time
3 Pole Disconnect
Short Circuit Breaking Capacity up to 4kA
Voltage resettable version available
Customised versions available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MS-25-A220-240
Functions
Shunt Trip release for 3 Phase Motor Protection Switch
Nominal Voltage
230VAC @ 50/60Hz
Nominal Current Range
6 Amp RMS @400VAC
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Rated Operations
100,000 Ops
Insulation Voltage
690V
Overload Protection
Thermal and Magnetic Release
Breaking Capacity
N/A
Approvals
CSA, EAC
Standards
IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
100g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
ACXP06R (BLR-CX Plus 06R), CX-Plus Power Factor Regulator, 6 Step, 1 Phase Measurement, 3 Phase Control, 110-480V 50/60HZ, Step Time Recording, Alarm Recording
Single CT Sensing
Isolated Switching of Power Factor Correction Contactors
Cos Ï• Setting 0.85 to 0.95 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 6 steps
Measurement System - Automatic/Manual
90-550VAC Aux/Measurement Supply
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
Â
Specification
Beluk Part Number
ACXP06R (BLR-CX Plus 06R) / 3ACXP06R-BEL-G
Function
Reactive Power Correction
Nominal Voltage (Un)
110-480VAC Line to Line
Supply Voltage
90-300VAC (L-N), 15VA 45-65Hz
Relay Rating
250VAC/10Amp
Switch Delay Time
1s - 1200s User Adjustable
Alarm
1 x Relay as above
Temperature/Fan Alarm
1 x Relay as above
Re-connection Delay Time
50 - 1200s User Adjustable
Desired Power Factor
0.80 IND - 0.80 CAP
Number of Output Relays
6
Smallest Capacitor Current
10mA
CT Input Range
0 - 6 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
Optional
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
User Manual
Modbus user Manual
Comparison of CX and CX Plus Controllers
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Quick Start Guide(Blog)
PFC 12-12-R-RTC, Power Factor Regulator & Kwh Power Quality Meter 144x144mm (Epcos BR 6000) wit RTC, 12 Step, 30-550V 50/60HZ, 240VAC Aux
Single 1/5A CT Sensing
Automatic Step Sensing (After start up sequence)
Isolated Switching of Power Factor Correction Contactors
Cos Ï• Setting 0.85 to 0.95 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 12 steps
Measurement System - Automatic/Manual
230VAC Aux Supply
Modbus RS485
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
Â
Specification
Rishabh Part Number
PFC 12-12-R-RTC
Function
Reactive Power Correction
Nominal Voltage (Un)
110-480VAC Line to Line
Supply Voltage
240VAC (L-N), 15VA 40-70Hz +/-10%
Relay Rating
250VAC/10Amp
Panel Size
144 x 144mm
Switch Delay Time
10s - 1800s User Adjustable
Alarm
1 x Relay as above
Temperature Alarm
1 x Relay as above
Re-connection Delay Time
10 - 1800s User Adjustable
Desired Power Factor
0.80 IND - 0.80 CAP
Number of Output Relays
13
Smallest Capacitor Current
10mA
CT Input Range
1/5Â Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485
Termination Style
Screw
Weight
700g
Certification
IEC 61326-1:2012, Table 2 (EMC), IEC 62053-21 (Accuracy), IEC 61010-1-2010 (Safety), IEC60529 (IP Rating Dust & Water)
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to IEC 61010-1-2010, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
Product Datasheet
User Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Quick Start Guide(Blog)
TGB2-ES542G, 40MM Emergency Stop Button, 1 Pos, Twist Release, 1 x NC, IEC60947-5-1
Emergency Stop Buttons are used to Isolate Control Power. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
600V Insulation Rating
240VAC @ 3 Amp
22mm Cutout
30mm,40mm,60mm Button Sizes
Twist or Key Release Types
Standards :
IP20
IEC60947-5-1
CE
Specification
TRENT Part Number
TGB2-ES442G
Functions
1 Pole Emergency Stop 40MM
Switch Type
Twist Release 1 x NC
Nominal Voltage
240VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
3 Amp @240VAC
Rated Insulation Voltage
600VAC
Humidity
35-85%
Approvals
CE
Standards
IEC60947-5-1, IP20 (IP40 Installed)
Weight
80g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Fastron Electronics SCT-Y24-50A/100mA, 50A/100mA Measurement, Class 1 Split Core CT's, Easy Click HY2.0 Connector for CRJ-31 RJ45 Splitter
Features
Quick Release Split Core System
Cable Mount
100mA Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads with HY-2.0 Connector
Applications
Eastron Modular Metering Equipment
Energy Monitoring
Load Balancing
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-Y24-50A/100mA
Technology
Split Core AC Current Transformer
Ratio
50/100mA
Aperture Size
ø 24 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
100mA (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
50Amp x 1.2
Termination Style
0.9M Flying leads with HY-2.0 Connector
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
CRJ-31 Connector User Guide
Iskra IKD225-20-24VAC/DC, Two Pole 2 x NO Modular Contactor 240VAC 25 Amp, 24VAC/DC Control Voltage, Hum Free with Manual Overide
Features
25 Amp (rms) @ 240VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IKD225-20-24VAC/DC
Switching Type
2 x SPST NO
Approvals
CE
Coil Voltage
24VAC/DC
Load Rating
25 Amp
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
240VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
Gigavac GV242CAB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 24VDC Coil
Features
Hermetically Sealed
Side Mounting
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV242CAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
400+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M5), Side Mounted
Load Voltage Range
100 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
FPT-100 1200/5A 5P10 15VA, Protection Class CT, 1200/5A, Class 5P10 5VA, 103 x 64mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-100 1200/5A 5P10 5VA
Technology
Protection Class Current Transformer
Ratio
1200/5
Aperture Size
64 x 103mm
VA Rating
5VA
Accuracy Class
Class 5P10
Output
5 Amp ACÂ (x10)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10DegC / 50DegC
Continuous Current (max)
1200Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
3kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??