Crydom MCPC2425C, Solid Sate Relay based Phase Angle Controller,170-280VAC, 25 Amp, 0-10V Input
Features
Selectable Proportional Burst Control Input
Ratings from 25A to 90 Amp @ 180-530 VAC
SCR output for heavy industrial loads
Zero voltage turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
MCPC2425C
Switching Type
Phase Angle
ROHS/CE/UL
Yes
Control Voltage
0-10V Proportional Input Requires DC Power Supply
Load Current
25 Amp (rms)
Surge Capability
397Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
170-280VAC
Overvoltage Vpk
1200V
Termination Style
Terminal Plug & Screws
Unit Weight
87g
Factory Pack Qty
10
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Crydom PMP2450W or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Shinko BCR2A1009 Series Digital Indicating Controllers
• Program control, converter function are standard features
• 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
• Drip-proof / Dust-proof IP66 (front panel only)
• 9-step pattern (for SV and time) is a standard feature
• UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
• Each unit needs just 60 mm depth panel space
• EC Compliant (Details)
Specification
Shinko Part Number
BCR2A1009
Control Output
4-20mA
Input
Multirange (refer to datasheet)
Option 1
None
Option 2
Event Input
Mounting Style
48 x 96mm Panel Mount
Load Voltage Range
24VAC/DC
Termination Style
Screw
Weight
170g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BC Series Brochure
BC Series User Manual
BC Series RS485 Comms Manual
Shinko Product Guide
Fine Tuning Adjustments
Fastron Electronics FEFC203-100-T, 2 Stage EMI (RFI) Input [Inverter] Output [NON Inverter] Sine Wave Filter for 3-phase systems, 100 Amp, 400VAC
Features
Suitable alternative to Schaffner FN3258(Input) or FN5020(Output) Series
3 phase Input [Inverter] Output [NON Inverter] Sine Wave Filter with high attenuation
400VAC +10%
Applications
Input of VSD Drives or Controlled Rectifiers
Diesel Generator Output
CNC Machinese
Elevators
Power Supplies
For Industrial Applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Fastron Part Number
FEFC203-100-T
Rated Voltage
400V
Rated Current
100A
Filter Stages
2 Stage (3 Phase 3 wire)
Operating Temperature
-25°C to 85°C
Filter Type
Excellent Attenuation for Sine Wave Output, Moderate Attenuation for input Line Filtering
Leakage Current
N/A
Mounting
Panel Mount
Material
Metal
Termination Style
Screw
Weight
4kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
CE
Yes
Datasheet
Product Datasheet
Furison FC150A3, PID Temperature Controller for HVAC, 87.6x34.5mm (71x29m Cutout), 100-240VAC, 2 x Programmable Relay Outputs, Includes NTC Sensor
3-digit display suit refrigeration temperatures to 1 Degree
Drip-proof / Dust-proof IP64 (front panel only)
Each unit needs just 71 x 29mm panel space
3 minute delay protection
Automatic 15 minutes ON, 30 minutes OFF on sensor failure
Overtemperature Alarm including 10 Amp Relay, Buzzer and LED Blinking
Ultra High temperature 99 - 120 Deg C Displays "HH"
Specification
Furison Part Number
FC150A3
Control Output
2 x SPDT Relay 10A(Resistive)for Heat/Cool/Compressor/Alarm
Input
NTC Probe (Included with 2 Meter wire length)
Cooling/Cooling Outputs
2 x 230VAC 10 Amp Relay Contact
Mounting Style
71 x 29mm Panel Mount
Supply Voltage
100-240VAC
Termination Style
Screw
Weight
150g
Factory Pack Qty
1
Certifications
UL, CE
Datasheet
Download Datasheet
Furison FTC052-A3C, PID Temperature Controller for HVAC, 87.6x34.5mm (71x29m Cutout), 100-240VAC, 4 x Relay Outputs (one prgrammable), 3 x NTC Inputs, 2 x Digital Inputs, Includes single NTC Sensor Only
3-digit display suit refrigeration temperatures to 1 Degree
Drip-proof / Dust-proof IP64 (front panel only)
Each unit needs just 71 x 29mm panel space
3 minute delay protection
Automatic 15 minutes ON, 30 minutes OFF on sensor failure
Overtemperature Alarm including 10 Amp Relay, Buzzer and LED Blinking
Ultra High temperature 99 - 120 Deg C Displays "HH"
Specification
Furison Part Number
FTC052-A3C
Control Output
4 x SPST Relay 10A(Resistive)for Heat/Cool/Compressor/Fan/Alarm
Input
3 x NTC Probe ( 1 only sensor Included with 2 Meter wire length)
Cooling/Cooling Outputs
4 x 230VAC 10 Amp Relay Contact
Mounting Style
71 x 29mm Panel Mount
Supply Voltage
100-240VAC
Termination Style
Screw
Weight
150g
Factory Pack Qty
1
Certifications
UL, CE
Datasheet
Download Datasheet
AT-DAO(0-10)-A-1, DC Current Transducer, 0-10Amp DC, 22-60VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-DAO(0-10)-D-1
Control Output
4-20mA
Input
0-10 Amp DC
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
GMTA-DV7A-AA, DC Voltage Transducer with Dual Output and separate scale, 0-600VDC Input, 100-240VAC/DC Aux, 2 x 4-20mA Outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Part Number
GMTA-DV7A-AA
Control Output
2 x 4-20mA Analogue Outputs
Input
0-600VDC
Alarm Type
2 x SPDT CO Relay 3 Amp (2 Independent Alarms)
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-100%
Zero Adjustment Range
+/-100%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
250g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron TC5-L-1U-2-G-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TC5-L-1U-2-G-2
Control Output
0-10V
Input
Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 96x96mm with SSR/Relay output)
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Thyro-A-1A-230-30-H3, Thyro-A-1A-Series Single Phase SCR Controller 30Amp 230VAC +10%/-57%, Voltage Control, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Rating_30 Amp
Features
Optional Profinet, Profibus, Ethernet, Modbus Comms
230VAC +10%/-57%, Voltage Control, +10/-57% Voltage, Current or Power Control
Built in Fuse
Smallest footprint on the market
Single Phase Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
Quick TAKT Mode (QTM), VT Mode (on request)
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
Potentiometer Adjustment
USB Configuration/Bias Setting
Synchronisation Function (dASM Module Recommended)
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
AC Soft Starter (Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-1A-230-30-H3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
230VAC +10%/-57%, Voltage Control, +10/-15% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 30kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
LEM LV Series Closed Loop AC/DC Hall Effect Voltage Sensor
Features
Bandwidth DC to 40kHz
Multi Range through pin selection
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Voltage overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LV 25-400
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
400V
Measurement Range
0 - 600V
Output
25 mA @Vpn
Isolation
4.1 kV
Bandwidth
DC-40 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
0.8%
Termination Style
Fastron 6.3 x 0.8mm
Unit Weight
60g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron Electronics AM5A-A-DV1-A DC Ammeter DC Voltmeter & Transmitter
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5A-A-DV1-A
Alarm Output
1 x High or Low C/O Relay Alarm with Reset
Input
0 - 50mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
110- 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Iskra ISPRO BSR 25/440, Class I, II / Type 1,2 / B, C, Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Specifications
Iskra Doo part number
ISPRO BSR 25/440
Nominal Voltage
440VAC
No of Poles
3
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Additional Remote Contacts
YES
Protective element
MOV + GDT
Surge discharge rating
Imax up to 25 kA
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet