Search results for "tg@tetherzon$*오다집수수료코인이체구입"
-
SCT-F36-500, 0.333V, 500Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-500, 0.333V, 500Amp measurement Split Core CT's Class 1, 35mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-500 Technology Split Core AC Current Transformer Ratio 500/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
FESCT-055-500-5-IP65, 500Amp Measurement, 5 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Fastron Electronics FESCT-055-500-5-IP65, 500Amp Measurement, 5 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture Features Quick Release Split Core System 10m Flying Leads ø 55mm Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurement, 5 Amp Outputs Specification Fastron Electronics Part Number FESCT-055-500-5-IP65 Technology Split Core AC Current Transformer Ratio 500/5A Aperture Size ø 55mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Dimensions 180x138x52mm Mounting Style Panel Mount Operating Temperature Range -35°C / 55°C Continuous Current (max) 500Amp x 1.2 Termination Style 10M Twisted Pair 0.34mm^2 Unit Weight 2000g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$465.00
$548.70 inclGST -
FDV-25-V10-24, DC Voltage Transducer, Din Rail Mount, 0-25VDC, 0-10V output, 24VDC Supply Voltage, 150mS Response
Fastron FDV-25-V10-24, DC Voltage Transducer, Din Rail Mount, 0-25VDC, 0-10V output, 24VDC Supply Voltage, 150mS Response 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 5V DC output (for voltage output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Part Number FDV-25-V10-24 Analogue Output 0-10V Input 0 - 300VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 24VDC +/-15% Voltage Isolation (1 min) 2.5kV Accuracy 1% Response Time 150mS Termination Style Screw Mounting Style DIN Rail Mount Safety CE, UL94V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$265.00
$312.70 inclGST -
F921 DC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
F921 DC Series Current Transducer 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm Features Isolated measurement of DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-DC-XX-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 2500 Amp with External Sensor Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
TTH-31-SA3-1, Air Temperature Sensor and Transmitter 6 x 500mm w/1M Cable
Free Aus Post Shipping for $300 SpendFastron TTH-31-SA3-1, Air Temperature Sensor and Transmitter 6 x 500mm w/1M Cable 4-20mA Output 2 Wire Temp Measurement for 0 to 100 Deg C Max 500 x 6mm with 1M Cable 20 Second Response Time 12-30VDC Supply 150mA max Pt100 Temp Sensing Elements Specification Fastron Part Number TTH-31-SA3-1 Sensor Type RTD (Temperature) No of Wires 2 Shaft Length 500mm Shaft Thickness 6mm Approvals CE, ROHS Cable length 1 Meter Temperature Range 0 to 100 Deg C Mounting Style Through Hole Weight 45g Factory Pack Qty 1 Datasheet Datasheet Installation Guide Wiring Diagram
Free Aus Post Shipping for $300 Spend$219.00
$258.42 inclGST -
FESCTHY-3000-2500-100mV, 2500Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, HY2.0 Connection, 76x127mm Aperture
Fastron Electronics FESCTHY-3000-2500, 2500Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCTHY-3000-2500 Technology Split Core AC Current Transformer Ratio 2500/100mV Aperture Size 76x127mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 2500Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Datasheet Product Datasheet Installation Guide FESCTHY Install Guide
$208.00
$245.44 inclGST -
FESCT-3000-2500-100mV, 2500Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, HY2.0 Connection, 76x127mm Aperture
Fastron Electronics FESCT-3000-2500, 2500Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCT-3000-2500 Technology Split Core AC Current Transformer Ratio 2500/100mV Aperture Size 76x127mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 2500Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Datasheet Product Datasheet Installation Guide FESCTHY Install Guide
$208.00
$245.44 inclGST -
FESCT-51-1000-0.333V, 1000Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 51x51mm Aperture
Fastron Electronics FESCT-51-1000-0.333V, 1000Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture, Class 1 Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCT-51-1000-0.333V Technology Split Core AC Current Transformer Ratio 1000/0.333V Aperture Size 51 x 51mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 1000Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 950g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$105.00
$123.90 inclGST -
FESCT-055-500-1-IP65, 500Amp Measurement, 1 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Fastron Electronics FESCT-055-500-1-IP65, 500Amp Measurement, 1 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture Features Quick Release Split Core System 10m Flying Leads ø 55mm Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurement, 1 Amp Outputs Specification Fastron Electronics Part Number FESCT-055-500-1-IP65 Technology Split Core AC Current Transformer Ratio 500/5A Aperture Size ø 55mm VA Rating 2.5VA Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Dimensions 180x138x52mm Mounting Style Panel Mount Operating Temperature Range -35°C / 55°C Continuous Current (max) 500Amp x 1.2 Termination Style 10M Twisted Pair 0.34mm^2 Unit Weight 2000g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$517.00
$610.06 inclGST -
FESCT-32-250-100mV, 250Amp measurement Split Core CT's, Class 1, w/1M Flying Leads, HY2.0 Connection, 32x32mm Aperture
Fastron Electronics FESCT-32-250-100mV, 250Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 32x32mm Aperture, 100mV Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/2kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FESCT-32-250-100mV Technology Split Core AC Current Transformer Ratio 250/100mV Aperture Size 32 x 32mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 250Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9 Datasheet Product Datasheet
$82.50
$97.35 inclGST -
Cube400-M2-C-0.333V, Panel Mount kWh Meter, Class 1, 0.333V input, 2 pulse inputs or alarm/pulse outputs, RS485 Comms, Three line LCD Display
Free Aus Post Shipping for $300 SpendNorthern Design Cube 400-M2-C-0.333V Series 3 Phase Power Meter Optional 2 Pulse Input or Outputs Nominal current up to 6 A (For 5A CT Input) and nominal voltage up to 240V L-N Three Line Display Optional RS 232/RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Optional THD up to 15th Harmonic The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 1 Simple Menu Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication MODBUS and Ethernet communication protocol 240V AC power supply Specification Northern Design Part Number Cube 400-M2-C-0.333V Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 415V L-L 240V L-N, 0.333V Maximum Measurement Range 415V L-L 280V L-N, 0.4V Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 1 (kW,kWh) Class 1(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Ethernet Modbus RTU Over TCP/IP 2400-19200 b/s Weight 350g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Product Manual Product Comms Manual Application Notes Dual Tariff Guide CT Cable Losses Meter Accuracy at Low Current Current Input Isolation
Free Aus Post Shipping for $300 Spend$584.00
$689.12 inclGST -
SCT-F16-120, 120/0.333V Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-120-5A, 0.333V Output, 120Amp measurement Split Core Current Transformer, 16mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-120 Technology Split Core AC Current Transformer Ratio 120/0.333V Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 120Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST