F920-A-XX-XX-XX - Signal Conditioner and +/-15VDC Bipolar Power Supply with Adjustable High and Low C/O Relay Alarm. +/- 4V Bipolar Input, For External LEM Hall Effect Sensor
Features
Isolated measurement of AC or DC currents using a Hall effect transducer with external aperture.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned AC Average RMS or DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty, Otherwise 4-6 weeks
Datasheet
Datasheet
F921 Series AC Current Transducer with Process Outputs & High and Low Sold State Alarm
Features
Isolated measurement of AC currents using internal Hall effect transducer.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned AC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F921-X-XX-AC-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-8 Amp (Sensor dependant)
Maximum Measurement Range
8 Amp
Alarm
C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Dynex DCR1260F42 Thyristor(SCR) Capsule, 1260Amp, 4200V, 74/26
Features
Very low forward voltage drop
Very low leakage current
International standard package
74/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Dynex Part Number
DCR1260F42
Vrrm
4200V
Diode Configuration
Thyristor Capsule (PUK)
IF(av) @ 60 Deg C
1260 Amp
Package Size
ø74 x 26mm
Itsm
16.8 kA
VF(to)
0.91V
Tj(max)
125°C
rF
0.611mΩ
Gate Terminals
With 400mm Gate Leads
R th(j-c) (double sided cooled 180°sin)
0.0184°C/W
R th(c-h) (double sided cooled)
0.004°C/W
Weight
600g
Clamping Force
20 - 25kN
Factory Pack Qty
6
Certification
ROHS
Dynex Headquarters
UK
Datasheet
Product Datasheet
Alternatives
N1159NC400
Contact Us for Possible Replacement
Dynex 2022 Shorform Catalogue
Heatsink
Heatsink Profiles
Dynex DRD1230F40, Rectifier Diode PUK, 1260Amp, 4000V, 74/26 Capsule
Features
Very low forward voltage drop
Very low leakage current
International standard package
74/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Dynex Part Number
DRD1230F40
Vrrm
4000V
Diode Configuration
Diode Capsule (PUK)
IF(av) @ 100 Deg C
1225 Amp
Package Size
ø74 x 26mm
Itsm
20 kA
VF(to)
0.82V
Tj(max)
160°C
rF
0.29mΩ
Gate Terminals
Faston 4.8 x 0.8mm & 2.8 x 0.8mm
R th(j-c) (double sided cooled 180°sin)
0.022°C/W
R th(c-h) (double sided cooled)
0.004°C/W
Weight
600g
Clamping Force
18 - 22kN
Factory Pack Qty
12
Certification
ROHS
Dynex Headquarters
UK
Datasheet
Product Datasheet
Alternatives
Contact Us for Possible Replacement
Dynex 2022 Shorform Catalogue
Heatsink
Heatsink Profiles