LEM HAT 200-S, O/L Hall Efffect Current Transducer, 200 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output
Features
Bandwidth DC to 5kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 100 to 1500 A in one package.
Up to 2500 A measurement range
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
HAT 200-S
Technology
Open Loop Hall Effect
Aperture
40.5 x 30.5mm Square
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-600 Amp
Output
+/-4 V
Isolation
4.9 kV
Bandwidth
DC-25 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 80°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
300g
Factory Pack Quantity
10
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
2026 LEM Application Guide
Typical Bipolar Power Supply Wiring
Â
LEM DVC 1000-P, C/L Voltage Transducer, 1000V AC/DC, 5VDC Supply, 2.5Vref Output, PCB Mount
Features
Bandwidth DC to 47kHz
8 Pins
5V Unipolar Supply
Closed loop transducer using Hall Effect
Compact and versatile
PCB Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Single and Three Phase Inverters
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVC 1000-P
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
5VDC
Primary Nominal Voltage
+/-1000V AC/DC
Measurement Range
+/-1500V AC/DC
Output
2.5V Vref 1.17V -> 3.83V (0.5 to 4.5V over range) Instantaneous
Isolation
4.2 kV
Bandwidth
DC-47 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
22g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM AT 5 B10, AC Current Transformer, Self Powered, 5 Amp Average RMS 0-10V output
Features
Split Core
0-10V Average RMS Current Output
Cable Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ? 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
LEM Part Number
AT 5 B420L
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
Self Powered
Load Current (RMS)
5 Amp
Maximum Measurement Current (RMS)
6 Amp
Output
0-10V (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
45 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
1.5%
Aperture
? 16mm
Termination Style
Screw
Approvals
CE,UL,ROHS
Unit Weight
90g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
LEM HOYL 400-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 40 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYL 400-S-0100
Technology
Open Loop Hall Effect
Aperture
40 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
400 Amp
Measurement Range
+/-1000 Amp
Output
2.5 Vref
Isolation
8 kV
Bandwidth
DC-140 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
232g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM AT 50 B420L, AC Current Transformer, loop powered, 50 Amp Average RMS 4-20mA output,
Features
Average RMS Output
Split Core
4-20mA Current Output
Cable Mounting
20-30VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ? 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
LEM Part Number
AT 50 B420L
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
20-30VDC Loop Powered (10mA)
Load Current (RMS)
50 Amp
Output
4-20mA (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
55 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
1.5%
Termination Style
Screw
Unit Weight
90g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
Â
LEM HOYL 200-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 40 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYL 200-S-0100
Technology
Open Loop Hall Effect
Aperture
40 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-500 Amp
Output
2.5 Vref
Isolation
8 kV
Bandwidth
DC-140 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
232g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
VA1021B, Liquid PH Tester & Temperature Tester Portable with External BNC Connected Sensor. Range 0-14PH, 0-50 Deg C Accuracy 0.02PH/0.5 Deg C, WITH BLUETOOTH AND APP
Features
Portable /Battery Powered 3 x AAA (500 Hours)
External Sensor (BNC)
Range 0-14PH, 0-50 Deg C
Accuracy 0.02PH/0.5 Deg C
Bluetooth Comms
Free App
Specification
Â
Datasheet
Datasheet
LEM HAS Series Open Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 50kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, 50 to 600 A in one package.
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Specification
LEM Part Number
HAS 200-S
Technology
Open Loop Hall Effect
Aperture
20.4 x 10.4mm Square
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-600 Amp
Output
+/-4 V
Isolation
3.6 kV
Bandwidth
DC-50 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 80°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
60g
Factory Pack Quantity
10
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOYL 800-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 40 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYL 800-S-0100
Technology
Open Loop Hall Effect
Aperture
40 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
800 Amp
Measurement Range
+/-2000 Amp
Output
2.5 Vref
Isolation
8 kV
Bandwidth
DC-140 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
232g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM AP 400 B420L, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 4-20mA output, Infinite Overload Capability
Compact and versatile Split Core AC current sensor, selectable 200, 300, 400 Amp Average RMS 4-20mA output
Features
Split Core
Average RMS output
4-20mA current output
Busbar, or Din Rail mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 18.5mm x 18.5mm
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
AP 400 B420L
Technology
AC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
24VDC @ 30mA
Nominal Current (RMS + DC)
200,300,400 Amp Selectable
Overload
Infinite
Output
4-20mA Average RMS
Isolation
5kV (AC, 50Hz, 1 min)
Bandwidth
30-2000Hz
Mounting Style
Din Rail mount or Busbar mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Spring Terminal Block (Female Included)
Unit Weight
90g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HO 25-P Series Open Loop AC/DC Hall Effect Sensor
Features
Open loop current transducer
Fixed offset & sensitivity
Voltage output
Single supply +5 V
Overcurrent detect 2.63 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For PCB mounting
8x8mm Aperture
Advantages
Small size and space saving
Same package for wide primary current range
Creepage / clearance > 8 mm
High immunity to external interference
Fast response
High insulation capability
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
EN 50178: 1997
IEC 61010-1: 2010
IEC 61326-1: 2012
UL 508: 2010
Application Domain
Industrial.
Specification
LEM Part Number
HO 25-P
Technology
Open Loop Hall Effect
Aperture
8 x 8mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
25 Amp
Measurement Range
+/-62.5 Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-250 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1.35%
Termination Style
PCB Through Hole
Unit Weight
10g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM AT 10 B5, Split Core AC Current Transformer, Self Powered, 10 Amp Average RMS 0-5V output
Features
Split Core
0-5V Average RMS Output
Cable Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ? 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
LEM Part Number
AT 10 B5
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
Self Powered
Load Current (RMS)
10 Amp
Maximum Measurement Current (RMS)
Output
0-5V (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
55 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
1.5%
Aperture
? 16mm
Termination Style
Screw
Approvals
CE,UL,ROHS
Unit Weight
90g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet