FTA-010-420B-24, DC Current Transducer, +/-10 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-010-420B-24, DC Current Transducer, +/-10 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-10 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-10A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-010-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-10 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
HS501DR + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 9 Amps
Free Aus Post Shipping for $300 SpendCrydom HS501DR + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 9 Amps Features Proportional Phase Control Input Ratings from 25A to 90 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + MCBC2425CF Switching Type Burst Fire (Zero Crossing) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 9 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR MCBC Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
DTC1-S/M1-SP08, DIN Rail Mount HVAC Duct Heater PWM Controller, 0-5V Input, 24VAC/DC, 12VDC SSR Output
Free Aus Post Shipping for $300 spendFastron DTC1-S/M1-SP08, DIN Rail Mount HVAC Duct Heater PWM Controller, 0-5V Input, 24VAC/DC, 12VDC SSR Output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-S/M1-SP08 Control Output SSR 12VDC@30mA Input Multirange K/J/R/S/B/E/T/Linear Voltage 0-5V/Linear Current 4-20mA/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options PWM for HVAC Systems Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
KS24/A-48Z50-L, KS24/A-48Z50-L, Solid State Relay, 3 Phase 90-280VAC Control, 60A, 48-530VAC Load, LED Status Indicator + Cover, UL Approved
KS24/A-48Z50-L, Solid State Relay, 3 Phase 90-280VAC Control, 60A, 48-530VAC Load, LED Status Indicator + Cover Features Ratings from 60 Amp @ 48-530 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number KS24/A-48Z50-L Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 90 - 280VAC Load Current 60 Amp (rms) per Phase Surge Capability 600�Amp (peak) Special Feature LED Status Indicator + IP20 Cover Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 � Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement � App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$272.62
$321.69 inclGST -
G18WF, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Flange Mount Version
Free Aus Post Shipping for $300 SpendGigavac G18WF, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Flange Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G18WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 30 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
DVL 1000/SP7 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables
Free Aus Post Shipping for $300 SpendLEM DVL 1000/SP7 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Input and output cables Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1000/SP7 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Input and output cables Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
FTA-030-010-24, Hall Effect DC Current Transducer, +/-30 Amp , +/-10V Bipolar Output, 24VDC supply, 21mm Aperture
FTA-030-010-24, Hall Effect DC Current Transducer, +/-30 Amp , +/-10V Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-30 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-030-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-30 Amp Response Time < 120mS Output Bipolar +/-10V Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
84871130, AC/DC Current Monitoring Relay Selectable Over/Under Current with Latching Single Phase 0.1 - 10 Amp EIH Series, 24-240VAC/DC Supply, Under/Over
Free Aus Post Shipping for $300 SpendCrouzet Automation 84871130, AC/DC Current Monitoring Relay Selectable Over/Under Current with Latching Single Phase 0.1 - 10 Amp EIH Series, 24-240VAC/DC Supply, Under/Over For Current Monitoring of AC Current from 0.1 Amp to 10 Amp. Features: 0.1 to 10 Amp Trip Range 0 to 100% Hysteresis True RMS measurement Selectable Latching with Memory Function Specification Crouzet Part Number 84871130 (AC/DC C-Lynx Current Monitoring Relay With DPDT Contacts, latching and memory) Function Current Threshold Montoring Nominal Current 0.1- 10 Amp AC Digital Outputs 2 x C/O Relays, 24-240VAC/DC @ 5 Amp Min Breaking Current 10mA/5VDC Delay on Threshhold Crossing 0.1 → 3s (0, +10%) Delay on Pickup 600ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Adjustable Hysteresis 5 - 50% of Threshhold Maximum Measurement Cycle Time 30ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range 24VAC/DC 48VAC 120/220VAC +/-15% Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
88974162, Millenium 3 Essential XD26-16I/10O S, 16 x On/Off inputs, Incl 6 analogue inputs, 10 x Static Solid State outputs incl 4 x PWM output, 24 VDC
Free Aus Post Shipping for $300 SpendCrouzet 88974162 Millenium 3 Series Programmable Logic Controllers Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Allow the use of the entire library of specific functions blocs of the software workshop Extended temperature range (-20 °C →+70 °C) Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters) Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions HMI Screens Available Specification Crouzet Part Number 88974162 (XD26-16I/10O S) Analogue Inputs 0-10VDC (x6) Digital Inputs 12/24VDC (4.4mA @ 12VDC) (x16) Digital Outputs SSR, 12-24VDC @ 500mA (x10) PWM SSR Output 12-24VDC @ 500mA (x4) Expandable Yes LCD Display Yes Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VDC (21.6 - 28.8VDC) Termination Style Screw Weight 350g Certification CE, UL, CSA, GL Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Selection Chart Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14
-
ITN 12-P ULTRASTAB High Precision Hall Effect Current Sensor, 12.5 Amp, 35mA Output, No Aperture, +/-15V Supply
Free Aus Post Shipping for $300 SpendITN 12-P ULTRASTAB High Precision Hall Effect Current Sensor, 12.5 Amp, 35mA Output, No Aperture, +/-15V Supply Datasheet Product Datasheet
-
FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output
Free Aus Post Shipping for $300 SpendLEM FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2500-SUI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2500 Amp Measurement Range +/-7500 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
E500M-1042, Profinet Communication Module for Secure, Elite 500 Series
Elite E500M-1042, Profinet Communication Module for Secure, Elite 500 Series The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software
$617.00
$728.06 inclGST