Rish SIGMA 75 CTR5+5+5/5.CL0.5.10VA Summation Current Transformer
Rishabh Rish SIGMA 75 CTR5+5+5/5.CL0.5.10VA Summation Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (30mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish SIGMA 75 CTR5+5+5/5.CL0.5.10VA Technology AC Current Transformer Ratio 5+5+5/5 VA Rating 10VA Class 0.5 Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 8 Amp Termination Style Screw Unit Weight 500g Factory Pack Qty 5 Datasheet Product Datasheet
$129.00
$152.22 inclGST -
HS212F + FJTY220D80P, Single Phase Intelligent Phase or Burst Controller with 2 second Soft Start, 4-20mA,0-10V,0-5V,10K POT Input, 220VAC, 80 Amp @ 50 Deg C
Fastron HS212F & FJTY220D80P, Single Phase Intelligent Phase or Burst Controller with 2 second Soft Start, 4-20mA,0-10V,0-5V,10K POT Input, 220VAC, 80 Amp @ 50 Deg C 4-20mA,0-10V, 0-5V or 10K POT Proportional Phase Control Input Ratings from 25A to 120 Amp @ 180-280 VAC SCR output for heavy industrial loads Instantaneous turn-on output Direct bond copper substrate Direct power lead frame Epoxy free design Specification Trent part Number HS212F & FJTY220D80P Switching Type Phase Angle (Random Crossing)/ Burst Fire (10 cycles) Control Voltage 4-20mA,0-10V,0-5V,10K POT Proportional Input Load Current 80 Amp (rms) @ 50 Deg C Surge Capability 690Amp (peak) Special Feature Single Phase Proportional Controller + 2 Second Soft Start + Selectable Half Wave control Mounting Style Panel Mount Load Voltage Range 170-220VAC +15% (253VAC Max) Max Non Repetitive Peak Voltage 600 Vp Termination Style Barrier Strip Screw Dimensions 105 x 80 x 55mm Unit Weight 1100g Factory Pack Qty 20 Datasheet FJTY Series Voltage Regulators HS212 Datasheet
$345.00
$407.10 inclGST -
HS212 + FJTY220D80P, Single Phase Intelligent Phase or Burst Controller with 2 second Soft Start, 4-20mA,0-10V,0-5V,10K POT Input, 220VAC, 60 Amp @ 40 Deg C
10Fastron HS212 + FJTY220D80P, Single Phase Intelligent Phase or Burst Controller with 2 second Soft Start, 4-20mA,0-10V,0-5V,10K POT Input, 220VAC, 60 Amp @ 40 Deg C 4-20mA,0-10V, 0-5V or 10K POT Proportional Phase Control Input Ratings from 25A to 120 Amp @ 180-280 VAC SCR output for heavy industrial loads Instantaneous turn-on output Direct bond copper substrate Direct power lead frame Epoxy free design Specification Trent part Number HS212 + FJTY220D80P Switching Type Phase Angle (Random Crossing)/ Burst Fire (10 cycles) Control Voltage 4-20mA,0-10V,0-5V,10K POT Proportional Input Load Current 60 Amp (rms) @ 40 Deg C Surge Capability 690Amp (peak) Special Feature Single Phase Proportional Controller + 2 Second Soft Start + Selectable Half Wave control Mounting Style Panel Mount Load Voltage Range 170-220VAC +15% (253VAC Max) Max Non Repetitive Peak Voltage 600 Vp Termination Style Barrier Strip Screw Dimensions 105 x 80 x 55mm Unit Weight 1000g Factory Pack Qty 20 Datasheet FJTY Series Voltage Regulators HS212 Datasheet
$325.00
$383.50 inclGST -
MFC300-16-413F3D, Thyristor Diode Module, 300 Amp, 1200V
Techsem MFC300-16-413F3D, Thyristor Diode Module, 300 Amp, 1200V Features Thyristor for line frequency Pressure Contact Technology Electrically insulated base plate Industrial standard package Long-term stability 3600V Isolation 50mm Base Width Applications Power Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Softstart AC motor control AC power control Lighting and temperature control Specification Techsem Part Number MFC300-16-413F3D Vrrm 1600V Diode Configuration Thyristor Diode Module IF(av) @ 85 Deg C 300 Amp Package Size W:50mm L:115mm D:52mm Itsm 6.8 kA VF(to) 0.85V Tj(max) 125°C rF 0.8mΩ I(gt) @ 25 Deg C 180mA Terminals M8 Screw Hole Centres 80mm x 38mm(M6) Gate Terminals Spade (A 2.8 - 0.8 DIN 46244) R th(j-c) 0.12°C/W R th(c-h) 0.04°C/W Weight 800g Mounting Torque 5 Nm (12 Nm Terminals) Factory Pack Qty 8 Certification UL Listed, ROHS Techsem Headquarters China Datasheet Product Datasheet Alternatives See MCD312-16io1 for Solder bonded alternative or TD330N12K , TD250N12KOF for pressure contact alternative
$255.00
$300.90 inclGST -
FTM1-A05-V2-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 230VAC, 4 Amps @ 50 Deg C, Modbus RTU
Fastron FTM1-A05-V2-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 230VAC, 4 Amps @ 50 Deg C, Modbus RTU Features Phase Angle, and Burst Control Functions Made in China, Low cost Single Phase, Angle/Burst Controller 4-20mA/0-10V/0-5V input Proportional Control Phase Angle or Burst switching Digital Display and Controls Modbus RTU Applications Electrical Ovens, Kilns, or Furnaces HVAC Heaters Controlled Power Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for HVAC or Industrial Environments Specification Fastron Part Number FTM1-A05-V2-W0 Rated Operating Temperature 50°C SCR Configuration 3 Phase AC Switch Control Voltage 4-20mA/0-10V/0-5V/POT Load Current 4 Amps Per Phase @ 50 Deg C Derating 2% per 1 Deg C (approx) Control Range 0-100% Alarms 1 x NO Relay Contacts Special Feature Internal Fuse, Current Limit, Power Limit Comms Modbus RTU Mounting Style Panel Mount Switching Voltage Range 230VAC +/-10% Supply Voltage 230VAC +/-10% Dimensions H:260mm W:94mm D:187mm Soft Start N/A Termination Style Screw Unit Weight 2.5kg (4kg Packed) Factory Pack Qty 1 Technical Docs User Manual Brochure Video for How to Set Current/Voltage/Power limit
$369.00
$435.42 inclGST -
MFC110-12-223F3, Thyristor Diode Module, 110 Amp, 1200V, 22mm Package
Techsem MFC110-12-223F3, Thyristor Diode Module, 110 Amp, 1200V, 22mm Package Features Pressure Contact Technology Electrically insulated base plate Industrial standard package 2900V Isolation 22mm Base Width Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Deep Cycle Operation Rectifiers for UPS Battery Chargers Specification Techsem Part Number MFC110-12-223F3 Vrrm 1200V Diode Configuration Thyristor Diode Module IF(av) @ 100 Deg C 110 Amp Package Size W:20mm L:93mm D:30mm Itsm 2.6 kA VF(to) 0.8V Tj(max) 150°C rF 1.74mΩ Terminals M5 Screw Hole Centres 80mm (M6) Gate Terminals N/A R th(j-c) 0.27°C/W R th(c-h) 0.20°C/W Weight 175g Mounting Torque 4 Nm (4 Nm Terminals) Factory Pack Qty 15 Certification UL Listed Techsem Headquarters China Datasheet Product Datasheet Alternatives See VSKH91/14 for Solder Contact alternative of Contact Us for Possible Replacement for alternative part
$109.00
$128.62 inclGST -
AT-DAO(0-10)-D-1, DC Current Transducer, 0-10Amp DC, 22-60VAC/DC Aux, 4-20mA output
AT-DAO(0-10)-A-1, DC Current Transducer, 0-10Amp DC, 22-60VAC/DC Aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type) Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number AT-DAO(0-10)-D-1 Control Output 4-20mA Input 0-10 Amp DC Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 22 - 60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$209.00
$246.62 inclGST -
AT-DAO(0-10)-A-1, DC Current Transducer, 0-10Amp DC, 100-240VAC/DC Aux, 4-20mA output
AT-DAO(0-10)-A-1, DC Current Transducer, 0-10Amp DC, 100-240VAC/DC Aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type) Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number AT-DAO(0-10)-A-1 Control Output 4-20mA Input 0-10 Amp DC Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$209.00
$246.62 inclGST -
FP080080P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
FP080080P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP080080P Technology Split Core AC Clip On Current Transformer Ratio 800/5 Aperture Size 50 x 80mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
H-10-2-24, Split Core Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
H-10-2-24, Split Core Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, 0-10 Amp DC, 4-20mA Unipolar Output Features ⌀31mm Aperture Split Core DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-10-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-10 Amp Response Time < 200mS Output Unipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$415.00
$489.70 inclGST -
AT-AAO(0-1)-A-1, AC Current Transducer, 1 Amp Average RMS, 100-240VAC/DC Aux, 4-20mA output
Current Transducer, AT-AAO(0-1)-A-1, AC Current Transducer, 1 Amp Average RMS, 100-240VAC/DC Aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type) Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number AT-AAO(0-1)-A-1 Control Output 4-20mA Average RMS Input 0-1 Amp Rms Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$209.00
$246.62 inclGST -
SCT-F16-10-1A, 10/1Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-10-1A, 10/1Amp Measurement, Class 1 Split Core Current Transformer Features Quick Release Split Core System Cable Mount 1 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-10-1A Technology Split Core AC Current Transformer Ratio 10/1A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 10Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$48.00
$56.64 inclGST