Fastron Electronics GA5-D-A6-A-N, 96x48mm 5 DIGIT Digital Ammeter 4-20mA input, 100-240VAC/DC Supply
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
60mm Depth
Specification
Fastron Electronics Part Number
GA5-D-A6-A-N
Conditioner Output
N/A
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount (60mm depth)
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Schurter 3-108-701, 1 Stage 3 Phase + N EMC (RFI) Line Filter, 25 Amp, FMAD NEO, 520VAC, Very High Attenuation
Features
Line filter suitable for 3 Phase + N systems
Wide Temperature Range
Characteristics
Designed for demanding applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Suitable for use in equipment according to IEC/UL 60950
Line filter suitable for low current Inverter such as PV or battery storage systems
Specification
Schurter Part Number
3-108-701
Rated Voltage
520V 3 Phase
Rated Current
25A
Filter Stages
1 Stage
Operating Temperature
-40°C to 100°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.5mA
Mounting
Panel Mount - Case FF
Material
Metal
Termination Style
Screw
Weight
1.1kg
Factory Pack Qty
4
Protection Class
Suitable for equipment according to IEC/UL 60950
Isolation
1.3 - 2.75kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 3-108-713, 1 Stage 3 Phase + N EMC (RFI) Line Filter, 50 Amp, FMAD NEO, 520VAC, Very High Attenuation
Features
Line filter suitable for 3 Phase + N systems
Wide Temperature Range
Characteristics
Designed for demanding applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Suitable for use in equipment according to IEC/UL 60950
Line filter suitable for low current Inverter such as PV or battery storage systems
Specification
Schurter Part Number
3-108-713
Rated Voltage
520V 3 Phase
Rated Current
50A
Filter Stages
1 Stage
Operating Temperature
-40°C to 100°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
N/A
Mounting
Panel Mount - Case FF
Material
Metal
Termination Style
Screw
Weight
1.3kg
Factory Pack Qty
4
Protection Class
Suitable for equipment according to IEC/UL 60950
Isolation
1.3 - 2.75kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Fastron Electronics FESCT-3000-1250, 1250Amp 0.333V Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FESCT-3000-1250
Technology
Split Core AC Current Transformer
Ratio
1200/0.333V
Aperture Size
76x127mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
1250Amp x 1.2
Termination Style
Terminals
Unit Weight
3000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics SCT-F24-75-5A-CL2, 5 Amp, 75Amp measurement Split Core CT's CLASS 2 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-75-5A-CL2
Technology
Split Core AC Current Transformer
Ratio
75/5 Amp
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 2
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
75Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FDV-15-420-24, Battery DC Voltage Transducer, Din Rail Mount, 0-15VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-15-420-24
Analogue Output
4-20mA
Input
0-15VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Gigavac HXNC241CAB, Normally Closed Contactor SPST-NC 200 Amp 1500VDC, 24VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69K
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
HXNC241CAB
Main Contact Type
SPST-NC
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
200 Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
5.375kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
1500VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846, CE
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics CJ19-95A, Capacitor Duty Contactor 240/480/530VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
Capacitor Duty
Discharge Resistors
Three-pole contactors
Seven ratings from 12,5 kVAr to 60 kVAr
IEC 60947-4-1 for AC-6b utilization category
UL Approved
Advantages :
Conforms to utilization category AC-6b
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Switching of capacitor bank in parallel without de-rating
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz
Specification
Fastron Part Number
CJ19-95A
Functions
3 Pole Capacitor Duty Contactor
Nominal Voltage
230/480/530VAC @ 50Hz
Current Carrying Capacity as per UL
27kVar/Amp @230VAC, 50kVar/Amp@480VAC, 50kVar/Amp@530VAC, AC-6B
Auxiliary Contacts
2 x NO and 2 x NC
Trip Delay Time
2-10ms
Electrical Life
100,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
1,000,000 Ops
Control Voltage
230VAC
Power Dissipation
5.1W
Approvals
UL
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Premium Quality TC Cable 100M Teflon Type K Thermocouple Cable 100 Meter Laid Flat & Screened 7/0.3mm, ANSI Standard
Features
CE, ANSI, ROHS Approved
Colour Codes
Datasheet
Thermocouple Cable Brochure
Fastron FRI8-05/B, Current Monitoring Relay AC/DC 2-20 Amp, Adjustable Range, Universal 24-240VAC 24VDC
FRI8-05/B Series serves to monitor AC and/or DC currents 2,4,6,8,10,12,14,16,18,20 Amp Set points up to 20 Amp, and provides Relay alarm output with Over/Undercurrent selection by jumper. Can replace Crouzet 84871122
Features :
Current transducer is a part of the product. Inside this transformer there is a wire which senses the volume of fl owing current
Non Invasive measurement
Galvanically separates monitored circuit
Universal supply AC 24 - 240 V and DC 24 V Supply is galvanically separated from measuring current
Current withstand up to 100 A
Output contact: 1 x changeover/SPDT 8 A Clamp terminals 1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI8-05/B
Cable Aperture
8mm
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
2 - 20 A (AC/DC 50 Hz)
Current Trip Adjustment
2,4,6,8,10,12,14,16,18,20 Amp Setpoints
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
100 Amp
Time delay T1
max. 500 ms
Time delay T2
N/A
Output
CO Relay 8 Amp
Number of contacts
1 x changeover/ SPDT (AgNi / Silver Alloy)
Rating
8 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... 60C
Storage temperature
-30 ... 60C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Over voltage category
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI8-05/B serves to monitor current level in single phase AC/DC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Crydom HS151DR-PMP2450WP, DIN Mount, Proportional Controller, 170-280VAC 40 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
HS151DR + PMP2450WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
40 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR + Overvvoltage Protection
Mounting Style
Panel Mount
Load Voltage Range
170-280VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
1000g
Factory Pack Qty
20
Datasheet
Product Datasheet
PMP24 Installation/Wiring Guide
HS151DR Datasheet
Equivalent Parts
Contact Us for Possible Replacement