Search results for "비대면유심개통문의 gora43430aa 소액대출50만원내구제 고라통신 선불유심 현금화 정식업체 무서류간편대출 은평구 24시 당일소액급전대출"
-
HS211 + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 24 Amps
Free Aus Post Shipping for $300 SpendCrydom HS211 + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 24 Amps Features Proportional Phase Control Input Ratings from 25A to 90 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + MCBC2425CF Switching Type Burst Fire (Zero Crossing) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 24 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 MCBC Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
FGM6-3P-1600M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=65kA 1250 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-3P-1600M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 65kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 65kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1600M 1250A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 65kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 12.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
11125315 Regulator and Brushes for 11.203.331( AZF4229) MAHLE Alternator
Heavy Item - No Free ShippingISKRA LETRIKA 11125315 Regulator and Brushes for 11.203.331( AZF4229) MAHLE Alternator OEM MAHLE(Letrika) 11125315 Specification ISKRA (MAHLE) Part Number 11125315 ISKRA/LETRIKA/MAHLE 11125315
-
MOD1 3NL 63A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 18kA, 63 Amp, 400/690VAC
Free Aus Post Shipping for $300 SpendIskra Doo MOD1 3NM 63A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 18kA, 63 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 3 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MOD1 3NL 63A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 63 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current Icu = 36kA, Ics = 18kA @ 400VAC, Ics = 20kA @ 690VAC Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
Rish Xmer Split Core 4000/5 Amp 195/80 Class 1, 45VA Series Current Transformer, 85 x 172mm Aperture
Heavy Item - No Free ShippingRish Xmer Split Core 4000/5 Amp 195/80 Class 1, 45VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number Rish Xmer Split Core 4000/5 195/80 Technology Split Core AC Current Transformer Ratio 4000/5 Aperture Size 172 x 85mm VA Rating 45VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9 Datasheet Product Datasheet
-
KNL75-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, with 1 x NO 1 x NC, Nominal Current = 75 Amps, 24VAC Coil
Free Aus Post Shipping for $300 SpendIskra Doo KNL75-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, with 1 x NO 1 x NC, Nominal Current = 75 Amps, 24VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL75-11-24VAC Functions 3 Pole Contactor (3 x NO, with 1 x NO, 1 x NC Aux Contacts) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 75 Amp Continuous @ 55 Deg C Auxiliary Contacts 3 x NO, with 1 x NO, 1 x NC Aux Contacts (6 Amp) Optional NDL4-40, 4 Pole Snap On Aux Contacts Trip Delay Time 2-10ms Electrical Life 500,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VAC Power Dissipation 6W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 950g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
GX110BEB, Contactor SPST-NO, 1000+ AMP, 12-800VDC, 12VDC Coil, Coil Screw M4, SPST-NO Auxiliary Contact, IP67, IP69K, Deutsch 8 Pin Connector
Heavy Item - No Free ShippingGigavac GX110BEB, Contactor SPST-NO, 1000+ AMP, 12-800VDC, 12VDC Coil, Deutsch 8 Pin Connector, SPST-NO Auxiliary Contact, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX110BEB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 12VDC Load Current 1000+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 8 Pin Deutsch Connector Aux Contact Terminals 8 Pin Deutsch Connector Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M12 Unit Weight 1600g Factory Pack Qty 1 Datasheet Product Datasheet
-
DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols, PTB Approved for Billing Purposes
Free Aus Post Shipping for $300 SpendDCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols. PTB Germany Approved, or MID Approved for Billing 0-400/600 Amp Shunt Measurement Options (Included) Bi-Directional DC Measurement Voltage Measurement Range 150V to 1150V Backlit LCD 12VDC to 24VDC Supply Voltage Meter Operating Temperature -25°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max IP Enabled with DHCP 12 - 24VDC Supply Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Graphic LCD with illumination Specification LEM Part Number DCBM400, DCBM600 Functions DC Energy Meter Supply Voltage 12-24VDC Nominal Measurement Range 150VDC to 1000VDC Maximum Measurement Range 150 - 1150VDC Nominal Current Input Shunt Provided IP Conficguration Fixed or DHCP Accuracy Class B Mounting Din Rail Mount Real Time Clock NTP Time Sync over HTTPS/REST Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms HTTPS/REST, Ethernet IP, OCMF/SAFE Signed Data Weight 5/6kg Certification PTB, VDE-AR-E-2418-3-100 Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C ) Datasheet Product Datasheet Leaflet
-
LND2475, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Low Noise, Low EMC/RFI
Free Aus Post Shipping for $300 SpendCrydom LND2475, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Low Noise, Low EMC/RFI Features • Ratings from 25A to 75 Amp @ 24-280 VAC • SCR output for heavy industrial loads • Zero voltage or instantaneous turn-on outputs • UL/CSA/VDE Approved, CE Compliant to EN60950-1 • Improved SEMS screw and washer • Redesigned housing with anti-rotation barriers • AC & DC control types • Direct bond copper substrate • EMC compliant to Level 3 • Direct power lead frame • Epoxy free design Spec Crydom Part Number LND2475 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 3-32VDC Load Current 75 Amp (rms) Surge Capability 1145 Amp (peak) Special Feature None Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
Rish Xmer Split Core 3000/5 Amp 195/80 Class 1, 45VA Series Current Transformer, 85 x 172mm Aperture
Heavy Item - No Free ShippingRish Xmer Split Core 3000/5 Amp 195/80 Class 1, 45VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number Rish Xmer Split Core 3000/5 195/80 Technology Split Core AC Current Transformer Ratio 3000/5 Aperture Size 172 x 85mm VA Rating 45VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9 Datasheet Product Datasheet
-
HAZ 10000-SBI, O/L Current Transducer, 10000 Amp, +/-20mA Instant Output, +/-15VDC supply
Free Aus Post Shipping for $300 SpendLEM HAZ 10000-SBI, O/L Current Transducer, 10000 Amp, +/-20mA Instant Output, +/-15VDC supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 10000-SBI Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 12000 Amp Overload Rating 30000 At Output +/-20 mA Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DRA4D100E12, DC Motor Reversing Contactor, 12 Amp, 15-32VDC control, 100VDC Load
Free Aus Post Shipping for $300 spendCrydom DRA4D100E12, DC Motor Reversing Contactor, 12 Amp, 15-32VDC control, 100VDC Load Features 12 Amp DC Semiconductor Motor Controller Load voltage range up to 200VDC Optional Start/Stop Ramp/Break Panel Mount LED Forward and Reverse input status indicator 15-32VDC or 4.5-15VDC control C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Spec Crydom Part Number DRA4D100E12 Switching Type DC Load Approvals ROHS,UL,CE,IEC Control Voltage 15-32VDC Load Current 12 Amp DC Surge Capability (10ms) 110 Amp DC Special Feature FWD and REV LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 350g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies