Fastron Electronics SCT-F36-500-040A, 40mA, 500Amp Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
40mA Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-500-040A
Technology
Split Core AC Current Transformer
Ratio
500/40mA
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
500Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron Electronics SCT-F36-200, 0.333V, 200Amp measurement Split Core CT's Class 1, 36mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-200
Technology
Split Core AC Current Transformer
Ratio
200/0.333V
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron GPH2048ZA3, Solid State Contactor SSR, Single Phase 90-280VAC Control, 20A, 70-480VAC Load, Din Rail Mount
Ratings from 10A to 100 Amp @ 70-480 VAC
Contactor Style for retrofit
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
IP20
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Spec
Fastron Part Number
GPH2048ZA3
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90-280VAC
Load Current (single unit)
20 Amp (rms) @ 25 Deg C Ambient, 17 Amp (rms) @ 40 Deg C Ambient
Surge Capability
300 Amp (peak)
Special Feature
Contactor Style IP20 Terminals
Mounting Style
DIN Rail Mount
Load Voltage Range
70 - 480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
298g
Factory Pack Qty
20
Datasheet
Product Datasheet
Alternatives
SSR Style CKRA4830
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Powersem PSD35T/20 Single Phase Half Controlled Rectifier Bridge, Replaces Semikron SKD30/20
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Powersem Part Number
PSD35T/20
AC Line voltage
680V
Device Configuration
Three Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
38 Amp
Package Size
W:55mm L:45mm D:24mm
Itsm
400 A
VF(to)
0.85V
Tj(max)
150°C
rF
12mΩ
Terminals
M4 (1.5Nm)
Hole Centres
45mm (M4)
Gate Terminals
N/A
R th(j-c)
2.8°C/W
R th(c-h)
0.6°C/W
Weight
110g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
Powersem Headquarters
Germany
Datasheet
Product Datasheet
Crydom MCBC2425DL, Solid State Relay burst fire Controller, 240VAC, 4-20mA, 20 Cycles
Features
Selectable Proportional Burst Control Input
Ratings from 25A to 90 Amp @ 180-530 VAC
SCR output for heavy industrial loads
Zero voltage turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
MCBC4850DL
Switching Type
Burst Fire (20 Cycles)
ROHS/CE/UL
Yes
Control Voltage
4 - 20mA Proportional Input
Load Current
50 Amp (rms)
Surge Capability
250Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
180-280VAC
Overvoltage Vpk
600V
Termination Style
Terminal Plug & Screws
Unit Weight
87g
Factory Pack Qty
10
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Crydom PMP2425W or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Fastron Electronics FESCT-F36-500A/100mV, 500A/100mV Measurement, Class 1 Split Core CT's, 36mm Aperture
Features
Quick Release Split Core System
Cable Mount
100mVmp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads with -2.0 Connector
Applications
Eastron Modular Metering Equipment
Energy Monitoring
Load Balancing
Power Quality Measurements
Specification
Fastron Part Number
FESCT-F36-500A/100mV
Technology
Split Core AC Current Transformer
Ratio
500/100mV
Aperture Size
ø 36 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
100mV (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (mVx)
500Amp x 1.2
Termination Style
0.9M Flying leads with -2.0 Connector
Unit Weight
170g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
CRJ-31 Connector User Guide
Crydom HS211A + D2440, Panel Mount Solid State Relay, 3-32VDC Control Input, LED Status, 24-280VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount only
Spec
Part Number
HS211A + D2440
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
25 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211A
Series 1 AC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Infineon T828N04TOF Thyristor(SCR) Capsule
Features
Very low forward voltage drop
Very low leakage current
International standard package
48/14 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Controlled Rectifiers
AC Switch
Battery Chargers
Phase Controllers
Water Cooled AC switches
Power Factor Correction
Specification
Infineon Part Number
T828N04TOF
Vrrm
1600V
SCR Configuration
Thyristor(SCR) Capsule PUK
IF(av) @ 85 Deg C
828 Amp
Package Size
ø48 x 14mm
Itsm
13.5 kA
VF(to)
1V
Tj(max)
125°C
rF
0.23mΩ
Gate Terminals
Faston 4.8 x 0.8mm & 2.8 x 0.8mm
R th(j-c) (double sided cooled 180°sin)
0.045°C/W
R th(c-h) (double sided cooled)
0.01°C/W
Weight
110g
Clamping Force
5.5 - 8kN
Factory Pack Qty
12
Certification
ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
T1410N04TOF
T880N16TOF
Heatsink
Heatsink Profiles
H37 (Semikron P35) Heatsink Profile 40mm x 250mm, Various Lengths cut to order, Milled or Raw Finish
Note: for Milled finish. we can mill 150mm each pass leaving a line in the centre.
Note: for any lengths not showing in stock, and we have longer lengths in stock, the profile is available in 2-3 days to cut and mill.
Datasheet
Product Datasheet
Crydom HS501DR + A2450EG, Panel or Din Rail Mount Solid State Relay 24VAC Control Input, LED Status, 24-280VAC Output, 10 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + A2450EG
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
18-36VAC
Load Current
10 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
A2450E-G
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
LEM DK 100 B420, Split Core Hall Effect Current Transducer, 20, 50, 100A DC, 4-20mA unipolar output, 20-50VDC supply
Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V
Features
Split Core
DC Unipolar Measurement
4-20mA analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 21.7mm sqr
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
DK 100 B420
Technology
DC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
20-20VDC
Nominal Current (RMS + DC)
50,75,100 Amp Selectable
Response Time
< 100ms
Output
4-20mA Analogue
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
2%
Termination Style
2 x UNC8 Cylindric Head
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Semikron SKCH28/08, Single Phase Half Controlled Rectifier Bridge with Freewheeling Diode, 28 Amp, 800V
Features
For AC or DC Variable Voltage Output Up to 15KW
Electrically insulated base plate
Industrial standard package
2500V Isolation
UL Recognized E72445
Applications
Power Supplies
Rectifier for drives applications
Rectifiers for UPS
Battery Chargers
Spec
Semikron Part Number
SKCH28/08
AC Line voltage
240V
Device Configuration
Single Phase Half Controlled Rectifier Bridge,
DC Output @ 85 Deg C
30 Amp
Package Size
W:31.7mm L:63.5mm D:19.7mm
Itsm
320 A
VT
2.25V
Tj(max)
125°C
rF
Not Published
Terminals
Faston (6.3mm)
Hole Centres
48.2mm (M5)
Gate Terminals
Faston (6.3mm)
R th(j-c)
0.9°C/W
R th(c-h)
Not Published
Weight
42.5g
Isolation
2.5kV
Factory Pack Qty
20
Certification
UL Listed
Crydom Headquarters
United States
Datasheet
Product Datasheet
Alternatives
See B514F-2T, B612F-2T, B614F-2T or PSFH70-16 for higher rated equivalents