Fastron Electronics FESCT-075-800-1-IP65, 800Amp Measurement, 1 Amp Output Split Core CT's, Class 1, 7.5VA, w/10M Flying leads, ø 75mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 75mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 1 Amp Outputs
Â
Specification
Fastron Electronics Part Number
FESCT-075-800-1-IP65
Technology
Split Core AC Current Transformer
Ratio
800/5A
Aperture Size
ø 75mm
VA Rating
7.5VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
800Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
F921 DC Series Current Transducer 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
Features
Isolated measurement of DC currents using a Hall effect transducer with external aperture.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F921-X-XX-DC-XX-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-400 Amp (Sensor dependant)
Maximum Measurement Range
2500 Amp with External Sensor
Alarm
C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Crydom PF240D25, Solid State Relay, SIP, 3-15VDC Control, 25A, 12-280VAC Load
Features
Ratings up to 25 Amp @ 660VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
PF240D25
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-15VDC
Load Current
25 Amp (rms)
Surge Capability
250 Amp (peak)
Special Feature
None
Mounting Style
PCB Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
25g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Accessories
Din Rail Holder
Â
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
DRG-01 (Generic 35mm DIN Rail Adaptor), UL94V0 DIN Rail Clips for Converting Panel Mount devices, Includes 2 mounting screws and 2 side clips, F2.90.98.000.1
Iskra Doo SQ0214 L230V RC S6SS Synchroscope (Synchronoscope)
Measurement of phase difference between bus bar and generator
Five instruments in one (SQ 0x14)
Circular display of ∆ phase difference
Magnifield display of phase difference ∆ = ±20
Microprocessor processing
Simple synchronization conditions setting
Output relay for synchronisation (pulse or continuous)
''Dead busbar or generator'' functionality
Power supply from bus bar or generator
Standard 96x96 mm or 144x144 mm din housing
LCD with backlight for voltage, frequency and/or ∆ monitoring (SQ 0x14 only)
High immunity to EMC disturbances
Special functions set with three jumpers inside the instruments Status output
Green led for indication of both voltages
Ship version (Bureau veritas certificate - SQ 02x4)
Â
Specification
Iskra Doo Part Number
SQ0214 L230V RC S6SS
Function
Phase Difference (∆ϕ) Measurement
Nominal Voltage (Un)
230VAC ± 20 % Line to Line (UL-N = 400 VMAX) @ 40-70Hz
Digital Output
Relay 250 V, 1 A, 50 Hz, 250 VA
Status Output
Open-Collector 24 Vdc + 20% @30mA
Switch On Delay Time Range
0,1 ... 1 s +/-10%
Phase Difference Setting Range
2 ... 20 °el ± 3 °el
Voltage Difference Setting Range
1 ... 10 % +/-2.5%
Dead Busbar Noise Rejection Range
10%, 20%, 30% or 40%
Power Consumption
< 4VA
Short Term Overload
2 x Un for 3 seconds
LCD Display Accuracy
Voltage 1.5%, Frequency 0.5%, Phase Difference +/-3 °el
Synchronisation Accuracy
+/- 10%
Termination Style
Screw
Weight
530g
Certification
CE
Factory Pack Qty
1
Enclosure Version
Ship Version
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP52 for case, IP20 for terminals with protective cover
Safety
According to EN 61 010-1 400 V, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Product Datasheet
User Manual
Application Notes & Software Downloads
The following parameters can be set via internal jumper see User Manual for more details.
Dead Busbar Generator Function
Over and Under Frequency Synchronising
Adjustable Lenght of a Sync Pulse
The following parameters Can be set via MIPack Comms Module & SQset Setting Software
Relay - 300mS/Continuous/Programmable
Dead Busbar - Active DB/Active DB + DG & % Threshold
MIPack User Manual
Download SQSet Settign Software
TA800E-LR24, Red LED Bead Replacements for 24AC/DC TRIB, TRI Series Indicators
LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24AC/DC (400VAC Special Orders)
AC & DC Sensing (Type A)
1 Pole Momentary
LED Illumination
Rated for 6 Amp @ 240VAC, or 0.3 Amp @ 240VDC
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TA800E-LR24
Functions
LED Indicator Bulb Replacement
Nominal Voltage
24AC/DC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Red LED
Approvals
CE
Weight
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TRENT TGD-2PL C 10-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 10 Amp, 10kA, 500VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
2 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type C, D Curve available
BidirectionalÂ
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB, RCM (Pending)
Specification
TRENT Part Number
TGD-2PL C 20-10kA
Functions
2 Pole MCB - C Curve
Nominal Voltage
500VDC @ 50/60Hz
Nominal Current Range
20 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Â
Datasheet
Product Datasheet
Trent 175AAF Series 690V, 175 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Features
Equivalent to Mersen 6.9 URT 217/175 K075909, Bussman 160EET, ETI BS17D/70/160A/690V
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1000 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
175AAF
Fuse Type
I²t AR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (IP < 30IN)
22800 A²/s
Nominal Current (RMS + DC)
175 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
90.2 x 30 x 36.7mm
Hole Centers
62.4 - 76mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
26W
Termination Style
M6
Unit Weight
61g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Cross Reference Chart