Rishabh Rish Con P 4WUB 100-500V 1/5A 60-300U 20 D, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 2 x 0-20mA/4-20mA/0-10V output, with display
Measures Active Power/Phase Angle/Power Factor
Measures Apparent/Reactive/Active Power
Digital output setting 0-20mA/4-20mA/0-10V
Dual output version available
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish P 4WUB 100-500V 1/5A 60-300U 20 D
Functions
Power/Phase Angle/Power Factor Transducer 4 wire
Measurement Output
4-20mA/0-20mA/0-10V User Selectable
Input
57 - 500VAC 50/60Hz
Overload (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-40 - 70°C
Supply Voltage
60 - 300VAC, or 24-60VAC/DC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
Technical Support
Rish Con P setup procedure blog
Fastron Electronics GT-AV(0-230)-A-VO(0-5), AC Voltage Transducer, 0-230V AC input, 100-240VAC/DC aux, 0-5V Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-230)-A-VO(0-5)
Control Output
0-5V Average RMS
Input
0-230VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh Rish SIGMA 75 CTR5+5+5/5.CL0.5.10VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish SIGMA 75 CTR5+5+5/5.CL0.5.10VA
Technology
AC Current Transformer
Ratio
5+5+5/5
VA Rating
10VA Class 0.5
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Datasheet
Product Datasheet
10Fastron HS212 + FJTY220D80P, Single Phase Intelligent Phase or Burst Controller with 2 second Soft Start, 4-20mA,0-10V,0-5V,10K POT Input, 220VAC, 60 Amp @ 40 Deg C
4-20mA,0-10V, 0-5V or 10K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
HS212 + FJTY220D80P
Switching Type
Phase Angle (Random Crossing)/ Burst Fire (10 cycles)
Control Voltage
4-20mA,0-10V,0-5V,10K POT Proportional Input
Load Current
60 Amp (rms) @ 40 Deg C
Surge Capability
690Amp (peak)
Special Feature
Single Phase Proportional Controller + 2 Second Soft Start + Selectable Half Wave control
Mounting Style
Panel Mount
Load Voltage Range
170-220VAC +15% (253VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
105 x 80 x 55mm
Unit Weight
1000g
Factory Pack Qty
20
Datasheet
FJTY Series Voltage Regulators
HS212 Datasheet
Techsem MFC182-16-216F3B, 182 Amp, 1600V, Thyristor Diode Module
Features
Pressure Contact Technology
Electrically insulated base plate
Improved temperature and power cycling
Planar passivated chips
Very low forward voltage drop
Very low leakage current
3600V Isolation
Industrial standard package
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
For single and three phase bridge configurations
Field supply for DC motors
Input rectifiers for PWM inverter
Specification
Techsem Part Number
MFC182-16-216F3B
Vrrm
1600V
Diode Configuration
Thyristor Diode Module
IF(av) @ 85 Deg C
181 Amp
Package Size
TO-240AA W:20mm L:93mm D:30mm
Itsm
7 kA
VF(to)
0.85V
Tj(max)
125°C
rF
1.26mΩ
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Trigger Current
N/A
R th(j-c)
0.22°C/W
R th(c-h)
0.08°C/W
Weight
320g
Mounting Torque
2.5 Nm (5 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Techsem MFC250-16-413F3D, Thyristor Diode Module, 250 Amp, 1200V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
50mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MFC250-16-413F3D
Vrrm
1600V
Diode Configuration
Thyristor Diode Module
IF(av) @ 85 Deg C
250 Amp
Package Size
W:50mm L:115mm D:52mm
Itsm
6.8 kA
VF(to)
0.85V
Tj(max)
125°C
rF
0.8mΩ
I(gt) @ 25 Deg C
180mA
Terminals
M8 Screw
Hole Centres
80mm x 38mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.12°C/W
R th(c-h)
0.04°C/W
Weight
800g
Mounting Torque
5 Nm (12 Nm Terminals)
Factory Pack Qty
8
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See MCD312-16io1 for Solder bonded alternative or TD330N12K , TD250N12KOF for pressure contact alternative
Techsem MFC300-16-413F3D, Thyristor Diode Module, 300 Amp, 1200V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
50mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MFC300-16-413F3D
Vrrm
1600V
Diode Configuration
Thyristor Diode Module
IF(av) @ 85 Deg C
300 Amp
Package Size
W:50mm L:115mm D:52mm
Itsm
6.8 kA
VF(to)
0.85V
Tj(max)
125°C
rF
0.8mΩ
I(gt) @ 25 Deg C
180mA
Terminals
M8 Screw
Hole Centres
80mm x 38mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.12°C/W
R th(c-h)
0.04°C/W
Weight
800g
Mounting Torque
5 Nm (12 Nm Terminals)
Factory Pack Qty
8
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See MCD312-16io1 for Solder bonded alternative or TD330N12K , TD250N12KOF for pressure contact alternative
Fastron FTM1-A05-V2-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 230VAC, 4 Amps @ 50 Deg C, Modbus RTU
Features
Phase Angle, and Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A05-V2-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
4 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
230VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit
Fastron Electronics AMB-DV4-D-N, 96x48mm DC Voltmeter 0-10V Input, 22-60VAC/DC supply, Large 4.1 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 4.1 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
90mm Depth
CE Approved
Specification
Fastron Electronics Part Number
AMB-DV4-D-N
Conditioner Output
N/A
Input
0 - 10VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
4.1 Digit RED LED
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Techsem MFC110-12-223F3, Thyristor Diode Module, 110 Amp, 1200V, 22mm Package
Features
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
2900V Isolation
22mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Deep Cycle Operation
Rectifiers for UPS
Battery Chargers
Specification
Techsem Part Number
MFC110-12-223F3
Vrrm
1200V
Diode Configuration
Thyristor Diode Module
IF(av) @ 100 Deg C
110 Amp
Package Size
W:20mm L:93mm D:30mm
Itsm
2.6 kA
VF(to)
0.8V
Tj(max)
150°C
rF
1.74mΩ
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
N/A
R th(j-c)
0.27°C/W
R th(c-h)
0.20°C/W
Weight
175g
Mounting Torque
4 Nm (4 Nm Terminals)
Factory Pack Qty
15
Certification
UL Listed
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See VSKH91/14 for Solder Contact alternative of Contact Us for Possible Replacement for alternative part
FP080080P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP080080P
Technology
Split Core AC Clip On Current Transformer
Ratio
800/5
Aperture Size
50 x 80mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
800Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Fastron Electronics SCT-F16-10-1A, 10/1Amp Measurement, Class 1 Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-10-1A
Technology
Split Core AC Current Transformer
Ratio
10/1A
Aperture Size
ø 15 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
10Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide