Search results for "tg탤"
-
H-200-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-200 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-200-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-200 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-200 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-200-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-200 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
DV 2000/SP2 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation
LEM DV 2000/SP2 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-2000 Specification LEM Part Number DV 2000/SP2 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,564.00
$1,845.52 inclGST -
HX360BAB, Contactor SPST-NO 800 AMP, 1500VDC, 12VDC Coil, 38cm Flying leads, with SPDT Auxiliary Contact 3750 Cycles, IP67, IP69
Gigavac HX360BAB, Contactor SPST-NO 800 AMP, 1500VDC, 12VDC Coil, 38cm Flying leads, with SPDT Auxiliary Contact 3750 Cycles, IP67, IP69 Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69 SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Specification Gigavac Part Number HX360BAB Main Contact Type SPST-NO Auxiliary Contact Type SPDT-NO Coil Voltage 12VDC Load Current 800 Amp Mechanical Life @ 0 Amp 300,000 Operations Dielectric at Sea Level (leakage <1mA) 5.375kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals 38cm Flying Leads Special Feature N/A Mounting Style Panel Mount (M6) Load Voltage Range 1500VDC Standards UL1604, IP67, IP69, SAE J1171, ISO8846 Termination Style M12 Unit Weight 3kg Factory Pack Qty 1 Datasheet Product Datasheet
$1,395.00
$1,646.10 inclGST -
G22WP-12VDC, HV Relay, 15kV, 50A, SPDT-CO, 12VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G22WP-12VDC, HV Relay, 15kV, 50A, SPDT-CO, 12VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G22WP-12VDC Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 12VDC Load Current 50 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 17kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
Thyro-A-3A-400-130-H3, Three Phase SCR Controller 130 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Advanced Energy Thyro-A-3A-400-130-H3, Three Phase SCR Controller 130 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-130-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$5,435.10
$6,413.42 inclGST -
LTC 1000-S/SP1 C/L Hall Effect Current Sensor, 1000 Amp, 250mA Output, +/-15..24V, Panel Mount, w/ feet, X = 0.4%
Free Aus Post Shipping for $300 SpendLEM LTC 1000-S/SP1 Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 3000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 1005-S/SP1 Technology Closed Loop Hall Effect Aperture ø42mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 3000 Amp Output 250 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
LT 2005-T C/L Hall Effect Current Sensor, Ipn = 2000 Amp, Isn = 400mA, +/-24VDC Supply, X = 0.3%, Busbar mount
Free Aus Post Shipping for $300 SpendLEM LT 2005-T C/L Hall Effect Current Sensor, Ipn = 2000 Amp, Isn = 400mA, +/-24VDC Supply, X = 0.3%, Busbar mount Features Bipolar and insulated current measurement up tp 3000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 2005-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/- 3000 Amp Output 400 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.3% Termination Style M5 theaded studs Unit Weight 4.4kg Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
N2500VC120, Thyristor(SCR) PUK, 1684 Amp, 1200V, 101/34
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N2500VC120, Thyristor(SCR) PUK, 1684 Amp, 1600V, 101/34 Features Very low forward voltage drop Very low leakage current International standard package 101/34 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode Part Number N2500VC120 Vrrm 1200V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 84 Deg C 1684 Amp Package Size ø101 x 34mm Itsm 37 kA VF(to) 0.88V Tj(max) 125°C rF 0.124mΩ Gate Terminals Faston R th(j-k) (double sided cooled 180°sin) 0.017°C/W R th(c-h) (double sided cooled) Weight 1kg Clamping Force 27 - 34kN Factory Pack Qty 6 Certification ROHS Westcode Headquarters UK Datasheet Product Datasheet Alternatives Contact Us for Possible Replacement Heatsink Heatsink Profiles
-
LV 200-AW 2 /6400, C/L Voltage Transducer 6.4kV, 80mA Output, +/-15/24VDC Supply
Heavy Item - No Free ShippingLEM LV 200-AW 2 /6400, C/L Voltage Transducer 6.4kV, 80mA Output, +/-15/24VDC Supply Features Bipolar and insulated voltage measurement up tp 6000VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 200-AW 2 /6400 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15/24 VDC Bipolar, Isolated Primary RMS Voltage 6400V Measurement Range +/- 9600 V Output 80 mA Isolation 12 kV Response 500uS Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style M5 threaded studs Unit Weight 2000g Factory Pack Quantity 6 Datasheet Product Datasheet
-
G18WP, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G18WP, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G18WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 30 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
G18WF, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Flange Mount Version
Free Aus Post Shipping for $300 SpendGigavac G18WF, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Flange Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G18WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 30 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
MT440-SSUDAANNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 & USB Comms
Free Aus Post Shipping for $300 SpendIskra Doo MT440-SSUDAANNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 & USB Comms Class 0.5 (EN 60688) USB Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy class 0.5 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Specification Iskra Doo Part Number MT440-SSUDAANNA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 1/5/10 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 370g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software MIPACK Programmer