Search results for "비대면유심개통문의 gora43430aa 소액대출50만원내구제 고라통신 선불유심 현금화 정식업체 무서류간편대출 은평구 24시 당일소액급전대출"
-
FRS 2000-SBIH, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version
LEM FRS 2000-SBIH, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2000-SU Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/-6000 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$995.00
$1,174.10 inclGST -
Thyro-A-3A-400-170-H3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Advanced Energy Thyro-A-3A-400-170-H3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-170-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$6,112.70
$7,212.99 inclGST -
AKR 50 C420L, AC Current Sensor, selectable 10, 20, 50 Amp, True RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 10, 20, 50 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 50 C420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 10,20,50 Amp Selectable Maximum Measurement Current (Peak) 17,34,85 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
MX11BCC, DC Contactor, Milspec SPST-NO, 150 AMP, 12-48VDC, 12VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact
Free Aus Post Shipping for $300 spendGigavac MX11BCC, DC Contactor, Milspec SPST-NO, 150 AMP, 12-48VDC, 12VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K Milspec MIL-R-6106 ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number MX11BCC Main Contact Type SPST-NO Auxiliary Contact Type SPST-NC Coil Voltage 12VDC Load Current 150 Amp Mechanical Life @ 0 Amp 300,000 Cycles Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 122cm Flying Leads Aux Contact Terminals N/A Special Feature Hermetically Sealed rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-48VDC Standards MIL-R-6106, IP67, IP69K, ROHS Termination Style M8 Unit Weight 500g Factory Pack Qty 1 Datasheet Product Datasheet
-
HXNC241FAB, Normally Closed Contactor SPST-NC 200 Amp 1500VDC, 48VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69K
Free Aus Post Shipping for $300 spendGigavac HXNC241FAB, Normally Closed Contactor SPST-NC 200 Amp 1500VDC, 48VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number HXNC241FAB Main Contact Type SPST-NC Auxiliary Contact Type SPST-NO Coil Voltage 48VDC Load Current 200 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 5.375kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 1500VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846, CE Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
-
HXNC241BAB, Normally Closed Contactor SPST-NC 200 Amp 1500VDC, 12VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69K
Free Aus Post Shipping for $300 spendGigavac HXNC241BAB, Normally Closed Contactor SPST-NC 200 Amp 1500VDC, 12VDC Coil, 38cm Flying leads, with SPST-NO Auxiliary Contact Continuous Duty, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number HXNC241BAB Main Contact Type SPST-NC Auxiliary Contact Type SPST-NO Coil Voltage 12VDC Load Current 200 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 5.375kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 1500VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846, CE Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
-
TGLW26-1021250, 1 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW26-1021250, 1 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary Load Break or Disconnect Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 1 Pole Momentary 64mm x 64mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TGLW26-1021250 Functions 1 Pole AC Disconnect Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 250Amp @400VAC Rated Insulation Voltage 690VAC Humidity 35-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 1.64kg Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
-
RISH CON-CV-AVG-06-50-I-01-H, AC Voltage Transducer, 50Hz, 230VAC Full Scale, 0-10V Output, 60-300VAC/DC Supply, LED Indicator
Free Aus Post Shipping for $300 SpendRishabh RISH CON-CV-AVG-06-50-I-01-H, AC Voltage Transducer, 50Hz, 230VAC Full Scale, 0-10V Output, 60-300VAC/DC Supply, LED Indicator Average RMS 0-10V output Dual output version available 250mS response time PC 94 UL V0 Each unit needs just 22.5 x 100.9 mm depth DIN Rail cabinet space Specification Rishabh Part Number RISH CON-CV-AVG-06-50-I-01-H Measurement Output 0-10V (Average RMS) Input 230VAC Amp 50/60Hz Overlaod (Continuous) 120% Overload (1 second) 150% Operating Temperature -40 - 70°C Supply Voltage 60 - 300VAC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet
-
HCT-0024-200, Split Core DC Hall Effect Current Sensor, 200 Amp, +/-4V Output, Split Core 24mm Aperture, X = 1%
Free Aus Post Shipping for $300 SpendMagnelab HCT-0024-100, Split Core DC Hall Effect Current Sensor, 200 Amp, +/-4V Output, Split Core 24mm Aperture, X = 1% Features Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification Magnelab Part Number HCT-0024-200 Technology Split Core Open Loop Hall Effect Aperture ø24mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/-300 Amp Output +/-4 V Isolation 4 kV Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style Flying Lead Unit Weight 400g Factory Pack Quantity 10 Datasheet Product Datasheet
-
MCS-I31, Current/Power Measurement Module for MCS Modular Metering System, 100mV CT input, Total, Net, Imp, Exp kwh, Kvarh and I1,I2,I3, P(Sum) , Q(Sum), S(Sum), PF(Sum), P,Q,S,PF Per Phase, THD-I
Free Aus Post Shipping for $300 SpendEastron Europe MCS-I31, Current/Power Measurement Module for MCS Modular Metering System, 100mV CT input, Total, Net, Imp, Exp kwh, Kvarh and I1,I2,I3, P(Sum) , Q(Sum), S(Sum), PF(Sum), P,Q,S,PF Per Phase, THD-I NON MID Version -> Will not lock you out after first CT configuration RS 485 communication up to 38,400 bit/s True RMS values of currents, and Power (when combined with MCS-U series) 100mV CT input The module is intended for measuring, and monitoring single-phase or 3 phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy Class 0.5 Measurement of Current, Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Specification Eastron Europe Part Number MCS-I31 Functions Three Phase / Single Phase Measurement ModuleModular kWh Meter Nominal CT Current Input 100mV Tariff Input N/A Accuracy Class 0.5 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Internal Memory N/A Dimensions 18mm x 90mm x 67mm (1 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size 18mm (1 Module) Operating Temperature -20 →+70 °C Documents Product Datasheet Modbus Utility EEM Meter Setting Software Utility
-
Rish Xmer 155/80 2000/5 Split Core CT Class 1 45VA, 85 x 125mm Aperture
Heavy Item - No Free ShippingRishabh Xmer CT Split 155/80 2000/5 Class 1 20VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 155/80 2000/5 SCCT Class 1 20VA Technology Split Core AC Current Transformer Ratio 2000/5 Aperture Size 85 x 125mm VA Rating 20VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet
-
DRA1-CMX100D6, Solid State Relay, 3-10VDC control, 100V, 6A DC output, DIN Rail Mount
Free Aus Post Shipping for $300 SpendCrydom DRA1-CMX100D6, Solid State Relay, 3-10VDC control, 100V, 6A DC output, DIN Rail Mount Features Ratings from 3A to 20 Amp @ 60-200VDC DIN Rail Mount Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Redesigned housing with anti-rotation barriers EMC compliant to Level 3 Epoxy free design Spec Crydom Part Number DRA1-CMX100D6 Switching Type DC Load ROHS Yes (Details) Control Voltage 3-10VDC Load Current 6 Amp DC Surge Capability (10ms) 100 Amp DC Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 0 - 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 11g Factory Pack Qty 20 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies