Search results for "multimeter"
-
FAT200D10, AC Current Transducer, 200Amp Measurement, 24mm Split Core, 0-10V Average RMS Output, Accuracy = 1%, 500mm Flying Leads
Fastron Electronics FAT200D10, AC Current Transducer, 200Amp Measurement, 24mm Split Core, 0-10V Average RMS Output, Accuracy = 1% Features Quick Release 24mm Split Core System Cale Mount 0-10V Output 24VDC Aux Rated System Voltage 0.60/2.5kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number FAT200D10 Technology 24mm Split Core AC Current Transformer Ratio 200/0-10V Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 0-10V (+20%) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 300g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$189.00
$223.02 inclGST -
Rish Xmer 155/80 1000/5 Split Core CT Class 1 15VA, 85 x 125mm Aperture
Rishabh Rish Xmer 155/80 1000/5 Split Core CT Class 1 15VA, 85 x 125mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Rishabh Part Number Rish Xmer 155/80 1000/5 SCCT Class 1 15VA Technology Split Core AC Current Transformer Ratio 1000/5 Aperture Size 85 x 125mm VA Rating 15VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9  Datasheet Product Datasheet Â
$295.00
$348.10 inclGST -
HO 120-NP-0100, O/L Multi Range Hall Effect Current Sensor, 120 Amp, No Aperture, PCB Mount
LEM HO 120-NP-0100 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for PCB mounting Factory calibrated Repositionable mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 120-NP-0100 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 120 Amp Measurement Range +/-300 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-350 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1.5% Termination Style PCB Through Hole Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$44.20
$52.16 inclGST -
CT 250/5, Class 0.5 5VA 50/21 (30) Current Transformer
Rishabh CT 250/5 Class 0.5 5VA 50/21 (30) Series Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 250/5 Class 0.5 5VA 50/21 (30) Technology AC Current Transformer Ratio 250/5 Aperture Size ⌀ 21mm or 20x10mm Busbar VA Rating 5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet
$34.00
$40.12 inclGST -
FATL300D420T, AC Current Transducer, 300Amp Measurement, 36mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, Terminal Version
Fastron Electronics FAT300D420T, AC Current Transducer, 300Amp Measurement, 36mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, Terminal Version Features Quick Release 36mm Split Core System Cale Mount 4-20mA Output 24VDc Aux Rated System Voltage 0.60/2.5kV 0.5M Flying Leads Applications Control Systems Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number FAT300D420T Technology 36mm Split Core AC Current Transformer Ratio 300/4-20mA Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 4-20mA (+20%) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Terminals Unit Weight 250g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$219.00
$258.42 inclGST -
FP100125P, 1000/5 Amp Split Core CT, Class 0.5, 5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm
FP100125P, 1000/5 Amp Split Core CT, Class 0.5, 5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Electronics Part Number FP100125P Technology Split Core AC Clip On Current Transformer Ratio 1000/5 Aperture Size 85 x 120mm VA Rating 5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 1000Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1  Datasheet Product Datasheet Installation Guide Â
$137.00
$161.66 inclGST -
SCT-F36-600, 0.333V, 600Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-600, 0.333V, 600Amp measurement Split Core CT's Class 1, 35mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-600 Technology Split Core AC Current Transformer Ratio 600/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-400-1A, 1 Amp, 400Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-400-1A, 1 Amp, 400Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 1 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F36-400-1A Technology Split Core AC Current Transformer Ratio 400/1 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9  Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$71.00
$83.78 inclGST -
FRT8-N2/W240, Multifunction Timer with Extended Functions 12-240 V AC/DC, 0.1s - 10 Days, 2 x SPDT 16 Amp
Fastron FRT8-N2/W240, Multifunction Timer with Extended Functions 12-240 V AC/DC, 0.1s - 10 Days, 2 x SPDT 16 Amp Features : Multi-range (0.1s - 10days) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input  Specification Fastron Part Number FRT8-N2/W240 Function Multifunction Timer Nominal Voltage 12 → 240 V AC/DC Digital Output 2 x C/O (SPDT) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Selectable 1s - 10 Days Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Certification CE, RoHS Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22  Datasheet Product Datasheet Fastron Monitoring/Time Relays Catalogue For items in our catalogue which are not listed online please Contact Us for Possible Replacement Â
$69.00
$81.42 inclGST -
AHR 1000 B420, Hall Effect Current Sensor, 1000Amp, True RMS 4-20mA output, 104 x 40mm aperture
LEM AHR 1000 B420, Hall Effect Current Sensor, 1000Amp, True RMS 4-20mA output, 104 x 40mm aperture Compact and versatile transducers for high AC and DC currents from 500 to 2000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features Split Core VFD and SCR waveforms current measurement True RMS output 4-20mA current output Busbar mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable or busbar up to 104 x 40mm High isolation between primary and secondary circuits Easy installation Applications -AC Power Supplies or Motors True RMS sensing - the most accurate way to monitor power supply or input power -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's and switch mode rectifiers. Current measurement gives faster response than temperature measurement. -Renewable Energy Installations or Backup Batteries Continuous condition monitoring allowing automatic failure detection and prediction -Application Domain Energy and Automation Specification LEM Part Number AHR 1000 B420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Nominal Current (RMS + DC) 1000 Amp Maximum Measurement Current (Peak) 2000 Amp Output 4-10mA Isolation 5.8kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 650g Factory Pack Qty 6  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
$735.00
$867.30 inclGST -
RCS-3600-4000 0.333V, , 3 Phase 4000Amp AC Measurement 12 Inch Rogowski Coils with Integrator, Class 1
RCS-3600-4000 0.333V, , 3 Phase 4000Amp AC Measurement 12 Inch Rogowski Coils with Integrator, Class 1 The RCS-3600 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt. A 9 to 36 VDC power supply is required to operate these coils. The RCS-3600 comes with an integrator which includes flexible strain relief cables. Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Magnelab Coils come with 10 year warranty  Specification Magnelab Part Number RCS-3600-4000 Function AC Current Measurement Nominal Measurement Current (Ipn) 4000 Amp RMS Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 9 - 36VDC Accuracy 1% from 25 to 3000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 12 Inch Coil Circumference 36 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 1200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide
$1,020.00
$1,203.60 inclGST -
LZZBJ6-12/185h/2 1000/1A 5P20 10VA 6.6kV, HV Protection Class Current Transformer
Fastron Electronics LZZBJ6-12/185h/2 1000/1A 5P20 10VA 6.6kV, HV Protection Class Current Transformer Features Panel Mount 1 Amp Output Self Powered Rated System Voltage 6.6kV Applications Indoor Substations Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number LZZBJ6-12/185h/2 1000/1A 5P20 10VA 6.6kV Technology HV AC Current Transformer Ratio 1000/1 Amp Aperture Size N/A VA Rating 10VA Accuracy Class Class 5P20 Output 1 Amp (+20%) Isolation 28kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 1000Amp x 1.2 Termination Style M12 Inserts Unit Weight 28kg Factory Pack Qty 1  Datasheet Product Datasheet Application Notes Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$1,995.00
$2,354.10 inclGST