Rishabh Instruments Rish DPM 96x96 A DC-420-24, 96x96mm DC Ammeter, Panel Mount, 4-20mADC Input, 24VDC Aux Supply, 4.1 Digit 0-19999 range
Default display is mA, for other dsiplay parameter please advsie
Features
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 4.1 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
55mm Depth
CE Approved
Specification
Rishabh Part Number
Rish DPM 96x96 A DC-420-24
Conditioner Output
N/A
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
24VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
4.1 Digit RED LED
Mounting Style
96 x 96mm (xD55mm)Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Crydom ED24D5, EMR plug in Solid State Relay, 3-15VDC control, 5 Amp 24-280VAC output
Features
Ratings 5 Amp @ 24-280VAC
Plug in EMR relay style
Motor controller rated
SCR output for reliable AC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED24D5
Switching Type
AC Load
ROHS
Yes (Details)
Control Voltage
5-15VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base, PCB Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
10
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Risbabh EMDC 6002-60-LA-C-2R, 4 Channel DC kWh Meter, Class 0.5, 150-150mV Shunt input, 10-60VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, 4 Line LCD Display, 12-70VDC Aux Supply, Internal Logging
2 Pulse/Alarm Outputs
50-150mV Shunt Input, and nominal voltage 10-60VDC
RS 485 communication up to 57,600 bit/s
USB Port
8MB Internal Storage
DC Measurement Only
The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.5
Simple Menu
RS 485 communication up to 57,600 bit/s
USB Comms
8MB Internal Logger
60-300VAC/DC power supply
Specification
Rishabh Part Number
EMDC 6002-60-LA-C-2R
Functions
4 Channel DC kWh Meter, Energy Meter
Supply Voltage
12-70VDC
Nominal Measurement Range
10-60VDC
Maximum Measurement Range
10-60VDC
Display
Single Line LCD
Pulse/Relay Output
2
Accuracy
Class 0.5 (Energy)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS485 Modbus RTU
YES 57,600bps
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Fastron Electronics FESCT-51-800-0.333V, 800Amp measurement Split Core Current Transformer, w/1M Flying leads, 51x51mm Aperture, Class 1
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FESCT-51-800-0.333V
Technology
Split Core AC Current Transformer
Ratio
800/0.333V
Aperture Size
51 x 51mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
800Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
950g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
LEM HAZ 6000-SB, Hall Effect Current Transducer, 6000A, +/-10V Instant Output, +/-15V supply
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
Features
Instantaneous output version +/-10V, +/-20mA
True RMS output versions 4-20mA, 0-10V putput
Hall effect measuring principle
Galvanic isolation between primary and secondary circuit
Instantaneous voltage output
Isolation voltage 17kV Rms /50 Hz /1min
Low power consumption
Package in PBT meeting UL 94-V0
Instantaneous voltage output
Advantages
Easy installation
Small size and space savings
Only one design for wide Ratings range
High immunity against external interference
Applications
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Power supplies for welding and telecom applications
Application domain
Industrial
Traction
Specification
LEM Part Number
HAZ 6000-SB
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
+/- 15VDC
Load Current (RMS + DC)
6000 Amp
Overload Rating
30000 At
Output
+/-10 V Instantaneous
Isolation
17kV (AC, 50Hz, 1 min)
Bandwidth
DC-3kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
F2023A (FUJICON)
Unit Weight
6kg
Factory Pack Qty
2
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM CKSR 25-NP Series Closed Loop AC/DC Hall Effect Sensor
Features
Closed loop current transducer
Voltage output
4.3kV Isolation
Frequency bandwidth 300kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Low power consumption
Compact design for PCB mounting
Advantages
CKSR footprint compatible
Very good dv/dt immunity
Low foot-print
Low offset drift
Reference pin with two modes REF IN and REF OUT
Extended measuring range for unipolar measurement.
High creepage / clearance distances
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Solar Inverter
Standards
EN 50178: 1997
UL 508: 2004
IEC 61010-1: 2010 (safety)
Application Domain
Industrial
Specification
LEM Part Number
CKSR 25-NP
Technology
Closed Loop Hall Effect
Aperture
None
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
25 Amp
Measurement Range
+/-85Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-300 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.8%
Termination Style
PCB
Unit Weight
9g
Factory Packaging
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Alternatives
LKSR 25-NP
Crydom HS501DR + DC60S3, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 3A @ 60 Deg C, 60VDC Load
Features
Ratings from 3A to 7 Amp @3-60VDC
SCR output
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + DC60S3
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5-32VDC
Load Current
3 Amp (rms) @ 40 Deg C
Surge Capability
10 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Recommended Voltage Range
3-60VDC
Max DC Voltage
60VDC
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
DC60 Series
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FTH6053ZD3 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 3-32VDC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH6053ZD3 + HS212
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS103DR
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Infineon D749N42T, Rectifier Diode Capsule
Features
Very low forward voltage drop
Very low leakage current
International standard package
58/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Infineon Part Number
D749N42T,
Vrrm
4200V
Diode Configuration
Diode Capsule (PUK)
IF(av) @ 85 Deg C
750 Amp
Package Size
ø58 x 26mm
Itsm
14 kA
VF(to)
0.85V
Tj(max)
180°C
rF
0.65mΩ
Gate Terminals
N/A
R th(j-c) (double sided cooled 180°sin)
0.039°C/W
R th(c-h) (double sided cooled)
0.005°C/W
Weight
280g
Clamping Force
10 - 24kN
Factory Pack Qty
12
Certification
ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
Contact Us for Possible Replacement
Heatsink
Heatsink Profiles
Fastron Electronics GT-DVO(0-60V)A-1, Signal Isolator/DC Voltage Transducer, 0-60VDC input, 100 - 240VAC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DVO(0-60V)A-1
Control Output
4-20mA
Input
0 - 60VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100 - 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Advanced Energy Thyro-A-3A-400-130-H-RLP3, Three Phase SCR Controller 130 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustments
Synchronisation Function for Multiple TAKT Sync
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (VAR Mode Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-3A-400-130-H-RLP3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Three Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-57% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Fastron Electronics FESCTHY-3000-1200, 1200Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FESCTHY-3000-1200
Technology
Split Core AC Current Transformer
Ratio
1200/100mV
Aperture Size
76x127mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mVAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
Terminals
Unit Weight
3000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Installation Guide
FESCTHY Install Guide