Gigavac GXL14C1AB, Latching Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K, High Side Drive Version
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GXL14C1AB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC (Low Side Drive, refer datasheet)
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C, High Side Drive Version
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics FEFC203-80-T, 2 Stage EMI (RFI) Input [Inverter] Output [NON Inverter] Sine Wave Filter for 3-phase systems, 80 Amp, 400VAC
Features
Suitable alternative to Schaffner FN3258(Input) or FN5020(Output) Series
3 phase Output Sine wave filter with high attenuation
400VAC +10%
Applications
Input of VSD Drives or Controlled Rectifiers
Diesel Generator Output
CNC Machinese
Elevators
Power Supplies
For Industrial Applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Fastron Part Number
FEFC203-80-T
Rated Voltage
400V
Rated Current
80A
Filter Stages
2 Stage (3 Phase 3 wire)
Operating Temperature
-25°C to 85°C
Filter Type
Excellent Attenuation for Sine Wave Output, Moderate Attenuation for input Line Filtering
Leakage Current
N/A
Mounting
Panel Mount - Case 32-7
Material
Metal
Termination Style
Screw
Weight
4.5kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
CE, ROHS
Yes
Datasheet
Product Datasheet
Techsem MTC570-18-416F3, Dual Thyristor Module, 570 Amp, 1800V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
60mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MTC570-18-416F3
Vrrm
1800V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
500 Amp
Package Size
W:60mm L:144mm D:52mm
Itsm
17 kA
VF(to)
0.9V
Tj(max)
125°C
rF
0.27mΩ
I(gt) @ 25 Deg C
250mA
Terminals
M10 Screw
Hole Centres
80mm x 48mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.065°C/W
R th(c-h)
0.02°C/W
Weight
1500g
Mounting Torque
6 Nm (12 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See MCC552-16io1
See TT570N16KOF
PGFM-211-B-A1-188, ELCI Marine Ground Fault Protection Relay for Single or Split Phase Systems, 27mA Detection, 50 Amp Max Ipn, 240VAC Supply, Panel Mount, Auto Reset, Note: Requires Suitable Air Pax Breaker
Features :
Suitable for Air Pax Breaker LEL Series
Applications :
On Board Vessel Earth Leakage Detection (Marine)
Specification
Sensata - Klixon Part Number
PGFM-211-B-A1-188
Supply Voltage
240VAC
Dimensions
⌀70.82mm x 59.77mm
Application
Earth Leakage Detection 27mA - 50 Amp
Trip Level
+/-27mA Nominal (Auto Reset)
Relay
Auto Reset, Requires Air Pax LEL Series Breaker
Protection
IP20
Approvals
E-11 GFP - UL 943 Category FTTJ2 when used in tandem with Airpax LEL series
Trip Time of Assembly
100mS or Less (60mS nominal)
Sensing Coil Voltage Limit
600VAC max
Operating Temnperature
-35 to 66 Deg C
Weight
200g
Mounting Style
Din Rail
Datasheet
Product Datasheet
Fastron Electronics FEFC203-100-T, 2 Stage EMI (RFI) Input [Inverter] Output [NON Inverter] Sine Wave Filter for 3-phase systems, 100 Amp, 400VAC
Features
Suitable alternative to Schaffner FN3258(Input) or FN5020(Output) Series
3 phase Input [Inverter] Output [NON Inverter] Sine Wave Filter with high attenuation
400VAC +10%
Applications
Input of VSD Drives or Controlled Rectifiers
Diesel Generator Output
CNC Machinese
Elevators
Power Supplies
For Industrial Applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Fastron Part Number
FEFC203-100-T
Rated Voltage
400V
Rated Current
100A
Filter Stages
2 Stage (3 Phase 3 wire)
Operating Temperature
-25°C to 85°C
Filter Type
Excellent Attenuation for Sine Wave Output, Moderate Attenuation for input Line Filtering
Leakage Current
N/A
Mounting
Panel Mount
Material
Metal
Termination Style
Screw
Weight
4kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
CE
Yes
Datasheet
Product Datasheet
Fastron Electronics FEFC203-40-T, 2 Stage EMI (RFI) Input [Inverter] Output [NON Inverter] Sine Wave Filter for 3-phase 3 wire systems, 40 Amp, 400VAC
Suitable alternative to Schaffner FN3258(Input) or FN5020(Output) Series
3 phase Output Sine wave filter with high attenuation
400VAC +10%
Applications
Input of VSD Drives or Controlled Rectifiers
Diesel Generator Output
CNC Machinese
Elevators
Power Supplies
For Industrial Applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Fastron Part Number
FEFC203-40-T
Rated Voltage
400V
Rated Current
40A
Filter Stages
2 Stage (3 Phase 3 wire)
Operating Temperature
-25°C to 85°C
Filter Type
Excellent Attenuation for Sine Wave Output, Moderate Attenuation for input Line Filtering
Leakage Current
N/A
Mounting
Panel Mount - Case 32-7
Material
Metal
Termination Style
Screw
Weight
2.5kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
CE
Yes
Datasheet
Product Datasheet
Gigavac GV141FAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 48VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Giagavac Part Number
GV141FAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
48VDC
Load Current
400+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
Internal Coil Supression
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 100VDC
Standards
CE, UL1604, IP67, SAEJ1171
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Magnelab MCT-0016-050, 50 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)
Features
Average RMS Output
Split Core
4-20mA Current Output
Cable Mounting
20-30VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
UL, CE, ROHS Approved
Advantages
Large aperture for cable up to ⌀ 24mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
Magnelab Part Number
MCT-0016-050
Technology
AC Current Transducer
Protection Class
IP50
Supply Voltage
20-30VDC Loop Powered (10mA)
Load Current (RMS)
50 Amp
Output
4-20mA (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
50 - 60Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
+/-2% Ripple on output
Termination Style
Screw
Aperture
16mm
Approvals
UL, CE, ROHS
Unit Weight
170g
Factory Pack Qty
6
Datasheet
Product Datasheet
Magnelab MCT-0016-020, 20 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)
Features
Average RMS Output
Split Core
4-20mA Current Output
Cable Mounting
20-30VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
UL, CE, ROHS Approved
Advantages
Large aperture for cable up to ⌀ 24mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
Magnelab Part Number
MCT-0016-020
Technology
AC Current Transducer
Protection Class
IP50
Supply Voltage
20-30VDC Loop Powered (10mA)
Load Current (RMS)
20 Amp
Output
4-20mA (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
50 - 60Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
+/-2% Ripple on output
Termination Style
Screw
Aperture
16mm
Approvals
UL, CE, ROHS
Unit Weight
170g
Factory Pack Qty
6
Datasheet
Product Datasheet
Vishay PhMKP525.3.25,00-84, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm IP20 Oil Filled, 25KVAR @ 525V, 17.6 KVAR @ 415VAC, 3 x 96.2uF
Characteristics and utility
25kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
UL 94 V0 Resin
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Vishay Part Number
PhMKP525.3.25,00-84
Technology
Oil Type
Dimensions
85 x 265mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
25 Kvar (17.6KVAR @ 415VAC)
Size
85 x 265mm
Capacitance
3 x 96.2uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
27.5 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
1.7kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Fastron Electronics AMB-D-V7-D-N, 96x48mm DC Voltmeter, Panel Mount, 0-600V DC Input, 24-60VDC supply, Large 4.1 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 4.1 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
90mm Depth
CE Approved
Specification
Fastron Electronics Part Number
AMB-D-V7-D-N
Conditioner Output
N/A
Input
600VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
22-60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
4.1 Digit RED LED
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles