Thyro-A-1A-230-350-H3, Thyro-A-1A-Series Single Phase SCR Controller 350Amp 230VAC +10%/-57%, Voltage Control, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Rating_350 Amp
Thyro-A-1A-230-350-H3, Thyro-A-1A-Series Single Phase SCR Controller 350Amp 230VAC +10%/-57%, Voltage Control, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Rating_350 Amp Features Optional Profinet, Profibus, Ethernet, Modbus Comms 230VAC +10%/-57%, Voltage Control, +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-1A-230-350-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC +10%/-57%, Voltage Control, +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,954.60
$3,486.43 inclGST -
LT 4000-S, C/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +/-15VDC Supply
Free Aus Post Shipping for $300 SpendLEM LT 4000-S, C/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +/-15VDC Supply Features Bipolar and insulated current measurement up tp 6000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 4000-S Technology Closed Loop Hall Effect Aperture 102mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 4000 Amp Measurement Range +/- 6000 Amp Output 800 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style M5 threaded studs Unit Weight 12.1kg Factory Pack Quantity 1 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
Thyro-A-3A-400-170-H-RLP3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options
Advanced Energy Thyro-A-3A-400-170-H-RLP3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-170-H-RLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$8,534.90
$10,071.18 inclGST -
LT 1005-S/SP4, C/L Current Transducer, Ipn = 1000A, +/-15/24VDC, 250mA Output, X = 0.4%
Free Aus Post Shipping for $300 SpendLEM LT 1005-S/SP4 Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 2000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 1005-S/SP4 Technology Closed Loop Hall Effect Aperture ø40.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 2000 Amp Output 250 mA Isolation 12 kV Bandwidth DC-150 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style M4 theaded studs Unit Weight 850g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
E500M-1042, Profinet Communication Module for Secure, Elite 500 Series
Elite E500M-1042, Profinet Communication Module for Secure, Elite 500 Series The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software
$617.00
$728.06 inclGST -
G61A741, HV Relay, 30kVDC, 10A, SPST-NO, 24VDC Coil, 1,000,000 Cycles, 40kV Isolation, 12" Flying Leads
Free Aus Post Shipping for $300 SpendGigavac G61A741, HV Relay, 30kVDC, 10A, SPST-NO, 24VDC Coil, 1,000,000 Cycles, 40kV Isolation, 12" Flying Leads Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency 3 x Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G61A741 Main Contact Type SPST-NO (1 Pole Normally Open) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 10 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals 12" Flying Leads Special Feature N/A Mounting Style Panel Mount (M4) Load Voltage Range 40kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 335g Factory Pack Qty 1 Datasheet Product Datasheet
-
G61B741, HV Relay, 30kVDC, 10A, SPST-NC, 24VDC Coil, 1,000,000 Cycles, 40kV Isolation, 12" Flying Leads
Free Aus Post Shipping for $300 SpendGigavac G61B741, HV Relay, 30kVDC, 10A, SPST-NC, 24VDC Coil, 1,000,000 Cycles, 40kV Isolation, 12" Flying Leads Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency 3 x Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G61B741 Main Contact Type SPST-NC (1 Pole Normally Closed) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 10 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M20 Screw Mounting Style Panel Mount (M4) Load Voltage Range 40kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 335g Factory Pack Qty 1 Datasheet Product Datasheet
-
G61B771, HV Relay, 30kVDC, 10A, SPST-NC, 24VDC Coil, 1,000,000 Cycles, 40kV Isolation, 72" Flying Leads
Free Aus Post Shipping for $300 SpendGigavac G61B771, HV Relay, 30kVDC, 10A, SPST-NC, 24VDC Coil, 1,000,000 Cycles, 40kV Isolation, 72" Flying Leads Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency 3 x DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G61B771 Main Contact Type SPST-NC (1 Pole Normally Closed) Auxiliary Contact Type N/A Coil Voltage 24VDC, 3 x Fomc C DC Coils Load Current 10 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals 72" Flying Leads Mounting Style Panel Mount (M4) Load Voltage Range 40kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 335g Factory Pack Qty 1 Datasheet Product Datasheet
-
G18WP-12VDC, HV Relay, 15kV, 30A, SPDT-CO, 12VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G18WP-12VDC, HV Relay, 15kV, 30A, SPDT-CO, 12VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G18WP-12VDC Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 12VDC Load Current 30 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 17kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
G18WF-12VDC, HV Relay, 15kV, 30A, SPDT-CO, 12VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Flange Mount Version
Free Aus Post Shipping for $300 SpendGigavac G18WF-12VDC, HV Relay, 15kV, 30A, SPDT-CO, 12VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Flange Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G18WP-12VDC Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 12VDC Load Current 30 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 17kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
Thyro-A-3A-400-280-HF-3, Three Phase SCR Controller 280 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Advanced Energy Thyro-A-3A-400-280-HF-3, Three Phase SCR Controller 280 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-280-HF-3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$6,387.48
$7,537.23 inclGST -
LV 100/SP47, C/L Voltage Transducer, 10mA Primary, +/-12..18VDC Aux, 50mA Output, SP47 = 9kV Isolation, -40 to 85 Deg C, +/-12-18VDC Aux Supply range
LV 100/SP47, C/L Voltage Transducer, 10mA Primary, +/-12..18VDC Aux, 50mA Output, SP47 = 9kV Isolation, -40 to 85 Deg C, +/-12-18VDC Aux Supply range Features Used for Voltage Transducer Design Current input and output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 100/SP47 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 12..18 VDC Bipolar, Isolated Primary Nominal Current 10mA Measurement Range +/- 20 mAmp Output 50 mA Isolation 9 kV Response time 20 - 100uS Mounting Style Panel Mount Operating Temperature Range 0°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 460g Factory Pack Quantity 6 Datasheet Product Datasheet
$835.00
$985.30 inclGST