Search results for "텔레@fundwash⟡:해외자금국내거래소fds뚫어주는곳"
-
FC5-M-W-1-G-4-C, PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output
Fastron FC5-M-W-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-M-W-1-G-4-C Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ SSR 12VDC 40mA Input Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 72x72mm with SSR/Relay output) Comms RS485 Modbus RTU 38400 Max Baud Rate Mounting Style 72x72mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$217.00
$256.06 inclGST -
FC5-S-1U-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,0-10V Output
Fastron FC5-S-1U-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,0-10V Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-S-1U-1-G-4-C Control Output 0-10V Input Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 48x48mm with SSR/Relay output) Mounting Style 48 x 48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$217.00
$256.06 inclGST -
FC5-H-1U-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm, 0-10V Output
Fastron FC5-H-1U-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm, 0-10V Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-H-1U-1-G-4-C Control Output 0-10V Input Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 48x96mm with SSR/Relay output) Mounting Style 48x96mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$217.00
$256.06 inclGST -
TRB-BD73, 2 x NO, 3 Position Toggle Switch BLACK, Right ON, Centre = OFF, Left Biased, 3 Amp @ 240VAC, Plastic/Metal, IEC60947-5-1
TRB-BD73, 2 x NO, 3 Position Toggle Switch BLACK, Right ON, Centre = OFF, Left Biased, 3 Amp @ 240VAC, Plastic/Metal, IEC60947-5-1 Toggle Switches are used to Toggle between 2 or 3 Digital or Analogue Input Signals or to simply turn off control signals. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe and reliable repetitive operation by the user. Features : 600V Insulation Rating 240VAC @ 3 Amp 22mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TRB-BD73-IP65 Functions 2 Pole, 3 Position Toggle Switch Switch Type Latching 1 x NO (Right ON Postion 1), Centre = OFF, 1 x NO (Left Biased Postion 2) Nominal Voltage 240VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 3 Amp @240VAC Rated Insulation Voltage 600VAC Humidity 35-85% Approvals CE Standards IEC60947-5-1, IP20 (IP40 Installed) Weight 65g Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Product Datasheet
$7.00
$8.26 inclGST -
TGLW30-4D100, 4 Pole Rotary/CAM Switch RED, 100 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
TGLW30-4D100, 4 Pole Rotary/CAM Switch RED, 100 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary CAM Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 4 Pole 2 Postion 64mm x 64mm Cutout Standards : IP40 Front, IP20 Terminals IEC 60947-1,-3 IEC 60204 Specification TRENT Part Number TGLW30-4D100 Functions 4 Pole AC Disconnect CAM Switch Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 100 Amp @400VAC Rated Insulation Voltage 690VAC Humidity 10-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 470g Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
$119.60
$141.13 inclGST -
FGA1-DN22, 6 Amp Snap on Auxiliary Contacts 4 Pole for FGC1, FGP1 Standard Contactors up to 95 Amp
FGA1-DN22, 6 Amp Snap on Auxiliary Contacts 4 Pole for FGP1-D, and FGC1-D Series Contactors up to 95 Amp Features Snap on 2 x NO, 2 x NC 6 Amp Contacts 90 grams
$15.00
$17.70 inclGST -
XY12038HBL 230VAC, AC FAN 120mm sq X 38mm 230V, 32 Watts, 94CFM, 2600-3000RPM Ball bearing, CE Approved
XY12038HBL 230VAC, AC FAN 120mm sq X 38mm 230V, 32 Watts, 94CFM, 2600-3000RPM Ball bearing, CE Approved Datasheet Product Datasheet
$28.75
$33.93 inclGST -
FDV-24-420-24, DC Voltage Transducer, Din Rail Mount, 0-24VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
Fastron FDV-24-420-24, DC Voltage Transducer, Din Rail Mount, 0-24VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 5V DC output (for voltage output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Part Number FDV-24-420-24 Analogue Output 4-20mA Input 0 - 24VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 24VDC +/-15% Voltage Isolation (1 min) 2.5kV Accuracy 1% Response Time 150mS Termination Style Screw Mounting Style DIN Rail Mount Safety CE, UL94V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$265.00
$312.70 inclGST -
GT-DVO(0-24V)D-1, DC Voltage Transducer, 0-30VDC input, 22-60VAC/DC aux, 4-20mA output
Fastron Electronics GT-DVO(0-24V)D-1, Signal Isolator/DC Voltage Transducer, 0-30VDC input, 22-60VAC/DC aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-DVO(0-24V)D-1 Control Output 4-20mA Input 0-24V Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$219.00
$258.42 inclGST -
GV244FPB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 48VDC Coil, PCB MOUNT, SPST-NO Auxiliary Contact, IP67
Gigavac GV244FPB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 48VDC Coil, PCB MOUNT, SPST-NO Auxiliary Contact, IP67 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Gigavac Part Number GV244FPB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 48VDC Load Current 400+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals PCB Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 100 - 800VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet
$265.00
$312.70 inclGST -
PV10-3A1500VDCgPV, GpV Solar Fuse 3Amp, 1500VDC @ 30kA, UL2579, IEC 60269, GB13539
PV10-3A1500VDCgPV, GpV Solar Fuse 3Amp, 1500VDC @ 30kA, UL2579, IEC 60269, GB13539 Features Meets the new UL and IEC photovoltaic standards UL Recognized for 1000 VDC High breaking capacity of 10 kA @ 1000 VDC Low min. interrupting rating of 1.35 x In Meets the requirements of IEC 61730-2 for PV module safety Applications All photovoltaic applications Inverters Battery charge controllers In-line protection String fuses Specification Vicfuse Part Number 8020.2053 Fuse Type I²t GpV Class Fast Blow Nominal Voltage 1000VDC, 275VAC I²t Rating (Pre-Arcing) 3150 A²/s Nominal Current (DC) 30 Amp Tested Breaking Capacity 10kA @1000VDC Dimensions 10.3 x 38mm Fuse Holder VCB10-30X15 Mounting Style Requires fuse holder Operating Temperature Range -40°C / 125°C Watt Loss 1.8W DC Breaking Capacity 10kA Unit Weight 8g Factory Pack Qty 10 Datasheet Product Datasheet Compatible Fuse Holder VCB10-30X15
$13.90
$16.40 inclGST -
PV10-2A1500VDCgPV, GpV Solar Fuse 2Amp, 1500VDC @ 30kA, UL2579, IEC 60269, GB13539
PV10-2A1500VDCgPV, GpV Solar Fuse 2Amp, 1500VDC @ 30kA, UL2579, IEC 60269, GB13539 Features Meets the new UL and IEC photovoltaic standards UL Recognized for 1000 VDC High breaking capacity of 10 kA @ 1000 VDC Low min. interrupting rating of 1.35 x In Meets the requirements of IEC 61730-2 for PV module safety Applications All photovoltaic applications Inverters Battery charge controllers In-line protection String fuses Specification Vicfuse Part Number 8020.2053 Fuse Type I²t GpV Class Fast Blow Nominal Voltage 1000VDC, 275VAC I²t Rating (Pre-Arcing) 3150 A²/s Nominal Current (DC) 30 Amp Tested Breaking Capacity 10kA @1000VDC Dimensions 10.3 x 38mm Fuse Holder VCB10-30X15 Mounting Style Requires fuse holder Operating Temperature Range -40°C / 125°C Watt Loss 1.8W DC Breaking Capacity 10kA Unit Weight 8g Factory Pack Qty 10 Datasheet Product Datasheet Compatible Fuse Holder VCB10-30X15
$13.90