Search results for "텔레:bpmc55~$다이어트약위고비심부름"
-
GO 4-SMS/SP3, O/L Hall Effect Current Sensor, 4 Amp, SMD, 3.3V Supply
GO 4-SMS/SP3, O/L Hall Effect Current Sensor with evaluation PCB, 4 Amp Features Hall effect measuring principle Galvanic separation between primary and secondary circuit Insulated test voltage 3000 V RMS Low power consumption Extremely low profile Single power supply +5 V Double overcurrent detection Fixed offset & sensitivity Response time 2 µs. Advantages Small size and space saving High immunity to external interference High insulation capability Industrial. Low electrical resistance (0.75 m?) No magnetic hysteresis Robust against external fields and cross-talk. Applications Appliances Small drives HVAC Solar E-Bikes Standards IEC 62109-1: 2010 IEC 60950-1: 2005 IEC 61800-5-1: 2007 UL 1577: 2014. Application Domains Industrial Specification LEM Part Number GO 4-SMS/SP3 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 4 Amp Overload Capability +/-200 Amp Output 2.5 Vref Isolation 2.5 kV Bandwidth DC-300 kHz Mounting Style Surface Mount - SOIC 8 Pin Operating Temperature Range -40°C / 125°C Accuracy 2% Termination Style N/A Unit Weight 10g Factory Pack Quantity 150 Datasheet Product Datasheet
$4.90
$5.78 inclGST -
Rish Xmer 155/80 3000/5 SCCT Class 0.5 20VA Series Split Core Current Transformer
Rishabh Xmer CT Split 155/80 3000/5 SCCT Class 0.5 20VA Series Split Core Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 155/80 3000/5 SCCT Class 0.5 20VA Technology Split Core AC Current Transformer Ratio 3000/5 Aperture Size 85 x 125mm VA Rating 20VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 3000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet
$295.00
$348.10 inclGST -
FP100080P, 1000/5 Amp Split Core CT, Class 0.5, 5VA Series Clip On Current Transformer
FP100080P, 1000/5 Amp Split Core CT, Class 0.5, 5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP10080P Technology Split Core AC Clip On Current Transformer Ratio 1000/5 Aperture Size 50 x 80mm VA Rating 5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FC5-W-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output
Fastron FC5-W-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-W-1A-2-G-4 Control Output 4-20mA Input Multirange Type E,J,N,T,S,R,B, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 96x48mm with SSR/Relay output) Mounting Style 96x48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$124.00
$146.32 inclGST -
FC5-H-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm, 0-10V Output
Fastron FC5-H-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm, 0-10V Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-H-1U-2-G-4 Control Output 0-10V Input Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 48x96mm with SSR/Relay output) Mounting Style 48x96mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-W-W-2-A-2 PID Controller 24VDC, with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm, Relay + 12VDC Output
Fastron FC5-W-W-2-A-2 PID Controller 24VDC, with 2 x Relay Alarms, 4-20mA Input, 96x48mm, Relay + 12VDC Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-W-W-2-A-2 Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ 12VDC @20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 96x48mm with SSR/Relay output) Mounting Style 96x48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$124.00
$146.32 inclGST -
FC5-M-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm,0-10V Output
Fastron FC5-M-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm,0-10V Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-M-1U-2-G-4 Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 72x72mm with SSR/Relay output) Mounting Style 72x72mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-H-W-2-G-4, 24VDC PID Controller with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,Relay + 12VDC Output
Fastron FC5-H-W-2-G-4, 24VDC PID Controller with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,Relay + 12VDC Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-H-W-2-G-4 Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/12VDC @ 20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 48x96mm with SSR/Relay output) Mounting Style 48x96mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Approvals CE Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-H-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,4-20mA Output
Fastron FC5-H-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-H-1A-2-G-4 Control Output 4-20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 48x96mm with SSR/Relay output) Mounting Style 96x48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-S-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,4-20mA Output
Fastron FC5-S-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-S-1A-2-G-4 Control Output 4-20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 48x48mm with SSR/Relay output) Mounting Style 48 x 48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-S-W-1-G-4, 24VDC PID Controller with 1 Alarm, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, Relay + 12VDC Output
Fastron FC5-S-W-1-G-4, 24VDC PID Controller with 1 Alarm, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, Relay + 12VDC Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-S-W-1-G-4 Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/SSR 12VDC @20mA Input Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input Option 1 1 Alarm standard Mounting Style 48 x 48 Panel Mount Supply Voltage 24VDC +/-15% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-L-1U-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,0-10V Output
Fastron FC5-L-1U-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,0-10V Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-L-1U-1-G-2-C Control Output 0-10V Input Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 96x96mm with SSR/Relay output) Mounting Style 96x96mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$235.00
$277.30 inclGST