Fastron FC5-H-1A-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-H-1A-1-G-2-C
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 48x96mm with SSR/Relay output)
Mounting Style
96x48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron FC5-M-1A-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-M-1A-1-G-2-C
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 72x72mm with SSR/Relay output)
Comms
RS485 Modbus RTU 38400 Max Baud Rate
Mounting Style
72x72mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
KZL-060-010-02D2, Single Phase Diode Rectifier Bridge, Switchable, 0.6Amp, 600V, for Uin max 270VAC rms
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Part Number
KZL-060-010-02D2
AC Line voltage
333V
Device Configuration
Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
0.6 Amp
Package Size
W13 x L:33 x H:23mm, 40mm Hole centers (Overall Length 46mm)
Itsm
750 A
VF(to)
0.85V
Tj(max)
150°C
rF
11mΩ
Terminals
M5 (5Nm)
Switching Terminals
screw
Weight
150g
Isolation
3kV
Factory Pack Qty
10
SQL50A 1000V, 3 Phase Diode rectifier Bridge, 50 Amp @ TC = 55 Deg C, 35 Amp @ Tc = 85 Deg C, 1000V
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Part Number
SKB 35/16
AC Line voltage
533V
Device Configuration
Three Phase Diode Rectifier Bridge
DC Output @ 62 Deg C
25 Amp
Package Size
W:55mm L:45mm D:24mm
Itsm
380 A
VF(to)
0.85V
Tj(max)
150°C
rF
12mΩ
Terminals
Faston (6.3mm)
Hole Centres
Single M5
Gate Terminals
N/A
R th(j-c)
9.3°C/W
R th(c-h)
0.9°C/W
Weight
22g
Isolation
3kV
Factory Pack Qty
10
Datasheet
Product Datasheet
Alternatives
See PSD51/18 for higher rated equivalent
E62.R17-124C60, 120uF, AC Film Capacitor ø116 x 176mm, M6x12 terminals with Bushing. C6 Design. Optimized For High RMS Currents, Voltage: 2000VDC/1200VAC
Characteristics and utility
120uF 1200VAC/1680VDC
Metalized Polypropylene Film
Connector type - M6 x 12mm Studs
M12 Stud mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
E62.R17-124C60
Technology
Metalized Polypropylene Film Capacitor
Dimensions
ø116 x 176mm
Mounting
M12 Stud
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
1075VAC/1680VDC
Operating Temperature Range
-40 to 85 °C
Capacitance
120uF
Tolerance On Capacitance
+10 / -10%
Lifetime
200,000 Hours @ 85 °C (Statistical Life)
Termination Style
M6 x 12 studs
Unit Weight
2kg
Factory Pack Quantity
21 (MOQ = 105)
Datasheet
Product Datasheet
Meanwell APV-12-12, 12VDC 1A 12W Constant Voltage Universal Power Supply with Flying Leads, Used as LED Driver
Supply Voltage: 120-370VDC or 85-264VAC
Output Voltage: 12V
Output Current: 1A
Power Rating: 12W
Connection: flying leads
Short Circuit, Overload, Overvoltage Protected
IP67 for internal wall mounting
Datasheet
Product Datasheet
Protec T1-1100PV-3+0-R, 1100VDC Surge Protection Device for Photovoltaic Systems, Type 1, Type 2/Open Type 1 SPD Listed, with Remote Contact
Specifications
Raycap part number
Protec T1-1100PV-3+0-R
Nominal Voltage
1100VDC
No of Poles
3
Category IEC / EN / VDE
Type 1, Type 2/Open Type 1 SPD Listed
Location of use
String Box, Inverter
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES
Protective element
MOV + GDT
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 12.5kA (10/350uS), 60kA(8/20uS)
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
FP010080P/40mA, 100/40mA Split Core CT, Class 1, Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP010080P/40mA
Technology
Split Core AC Clip On Current Transformer
Ratio
100/40mA
Aperture Size
50 x 80mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
40mA Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
100Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Fastron FT-AV(0-150)-D-1, Signal Isolator/Conditioner, 0-150V AC input, 24VDC aux, 4-20mA Average RMS output
Non Adjustable, Fixed Input and output span
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FT-AV(0-150)-D-1
Control Output
4-20mA Average RMS
Input
0-150VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
24VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-AV(0-150)-D-1, AC Voltage Transducer, 0-150V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-150)-D-1
Control Output
4-20mA Average RMS
Input
0-150VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FC5-S-W-1-G-4-C, 24VDC PID Controller with 1 Alarm, RS485 K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-W-1-G-4-C
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/SSR 12VDC @20mA
Input
Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input
Option 1
1 Alarm standard
Mounting Style
48 x 48 Panel Mount
Supply Voltage
24VDC +/-15%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Fastron FC5-L-1A-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Fastron Part Number
FC5-L-1A-1-G-4-C
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 96x96mm with SSR/Relay output)
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol