Search results for "텔레:bpmc55**마운자로단가위고비구매대행"
-
H37 Heatsink, Full Lengths or cut to order Milled or Raw Finish
H37 (Semikron P35) Heatsink Profile 40mm x 250mm, Various Lengths cut to order, Milled or Raw Finish Note: for Milled finish. we can mill 150mm each pass leaving a line in the centre. Note: for any lengths not showing in stock, and we have longer lengths in stock, the profile is available in 2-3 days to cut and mill. Datasheet Product Datasheet
$53.50 - $450.00
-
SDM230-Modbus-MID-V2, DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved, SAA212516
SDM230-Modbus-MID-V2, DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved, SAA212516 100 amp Direct Connect LoRaWaN AS923 communication Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) SAA Approved The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy Class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM230-Modbus-MID-V2 Functions Single Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 230V L-N 230V L-N, 100 Amp Maximum Measurement Range 276 L-N 230V L-N,100 Amp Nominal Current Input Direct connect 100 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 36mm x 100mm x 66mm (2 modules wide) Isolation 4kV LoRaWaN LoRaWAN AS923 Weight 250g Certification EN 61010-1 Installation Category III, SAA212516 Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Modbus Utility EEM Meter Setting Software Utility
$171.00
$201.78 inclGST -
GO 4-SMS/SP3, O/L Hall Effect Current Sensor, 4 Amp, SMD, 3.3V Supply
GO 4-SMS/SP3, O/L Hall Effect Current Sensor with evaluation PCB, 4 Amp Features Hall effect measuring principle Galvanic separation between primary and secondary circuit Insulated test voltage 3000 V RMS Low power consumption Extremely low profile Single power supply +5 V Double overcurrent detection Fixed offset & sensitivity Response time 2 µs. Advantages Small size and space saving High immunity to external interference High insulation capability Industrial. Low electrical resistance (0.75 m?) No magnetic hysteresis Robust against external fields and cross-talk. Applications Appliances Small drives HVAC Solar E-Bikes Standards IEC 62109-1: 2010 IEC 60950-1: 2005 IEC 61800-5-1: 2007 UL 1577: 2014. Application Domains Industrial Specification LEM Part Number GO 4-SMS/SP3 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 4 Amp Overload Capability +/-200 Amp Output 2.5 Vref Isolation 2.5 kV Bandwidth DC-300 kHz Mounting Style Surface Mount - SOIC 8 Pin Operating Temperature Range -40°C / 125°C Accuracy 2% Termination Style N/A Unit Weight 10g Factory Pack Quantity 150 Datasheet Product Datasheet
$4.90
$5.78 inclGST -
FC5-W-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output
Fastron FC5-W-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-W-1A-2-G-4 Control Output 4-20mA Input Multirange Type E,J,N,T,S,R,B, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 96x48mm with SSR/Relay output) Mounting Style 96x48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$124.00
$146.32 inclGST -
FC5-W-W-2-A-2 PID Controller 24VDC, with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm, Relay + 12VDC Output
Fastron FC5-W-W-2-A-2 PID Controller 24VDC, with 2 x Relay Alarms, 4-20mA Input, 96x48mm, Relay + 12VDC Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-W-W-2-A-2 Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ 12VDC @20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 96x48mm with SSR/Relay output) Mounting Style 96x48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$124.00
$146.32 inclGST -
FC5-S-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,0-10V Output
Fastron FC5-S-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,0-10V Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-S-1U-2-G-4 Control Output 0-10V Input Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 48x48mm with SSR/Relay output) Mounting Style 48 x 48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-S-R-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x48mm,Relay Output
Fastron FC5-S-R-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x48mm,Relay Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-S-R-2-T/R-2 Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Multirange Type,K,E,J,N,T,S,R,B, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 48x48mm with SSR/Relay output) Mounting Style 48 x 48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-S-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,4-20mA Output
Fastron FC5-S-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-S-1A-2-G-4 Control Output 4-20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 48x48mm with SSR/Relay output) Mounting Style 48 x 48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-L-1U-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,0-10V Output
Fastron FC5-L-1U-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,0-10V Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-L-1U-1-G-2-C Control Output 0-10V Input Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 96x96mm with SSR/Relay output) Mounting Style 96x96mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$235.00
$277.30 inclGST -
FC5-H-1A-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,4-20mA Output
Fastron FC5-H-1A-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-H-1A-1-G-2-C Control Output 4-20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 48x96mm with SSR/Relay output) Mounting Style 96x48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$217.00
$256.06 inclGST -
FC5-M-1A-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm,4-20mA Output
Fastron FC5-M-1A-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-M-1A-1-G-2-C Control Output 4-20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 72x72mm with SSR/Relay output) Comms RS485 Modbus RTU 38400 Max Baud Rate Mounting Style 72x72mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$227.00
$267.86 inclGST -
SQL50A 1000V, 3 Phase Diode rectifier Bridge, 50 Amp @ TC = 55 Deg C, 35 Amp @ Tc = 85 Deg C, 1000V
SQL50A 1000V, 3 Phase Diode rectifier Bridge, 50 Amp @ TC = 55 Deg C, 35 Amp @ Tc = 85 Deg C, 1000V Features Package with DCB ceramic base plate Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering UL registered, E 148688 Applications Heat and temperature control for industrial furnaces and chemical processes Lighting control Motor control Power converter Advantages Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability High power density Specification Part Number SKB 35/16 AC Line voltage 533V Device Configuration Three Phase Diode Rectifier Bridge DC Output @ 62 Deg C 25 Amp Package Size W:55mm L:45mm D:24mm Itsm 380 A VF(to) 0.85V Tj(max) 150°C rF 12mΩ Terminals Faston (6.3mm) Hole Centres Single M5 Gate Terminals N/A R th(j-c) 9.3°C/W R th(c-h) 0.9°C/W Weight 22g Isolation 3kV Factory Pack Qty 10 Datasheet Product Datasheet Alternatives See PSD51/18 for higher rated equivalent
$25.00
$29.50 inclGST