FP075080P, 750/5 Amp Split Core CT, Class 1, 2.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP075080P
Technology
Split Core AC Clip On Current Transformer
Ratio
750/5
Aperture Size
50 x 80mm
VA Rating
2.5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
750Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Varsi V385K20 Series Metal Oxide Varistor (MOV), 385VAC, 520VDC, K20 Package
High Energy Absorption Rating
Industry Standard Package
Wide Operating Range 35 - 1100VAC
High Peak Current Capability (70kA)
UL/CSA/ROHS/ISO9001:2015 Approved
Panel Mount
Screw Terminals
APPLICATION AREAS:
1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems).
2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes.
3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules.
Specification
Varsi Part Number
V385K20
Operating Voltage AC (50-60Hz)
385V
Operating Voltage DC
615V
Average Power Dissipation
1W
Permissable Peak Current
5.5kA
Energy Absorption(2ms)
287W(max)
Tolerance(Vn)
+/- 10%
Termination Style
Axial Lead
Weight
7g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CSA
Yes
Datasheet
Product Datasheet
Application Notes
Technical Blog MOV Article
Vishay VSKE91/14, Single Diode Module, 91 Amp, 1400V
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKE91/14
Vrrm
1400V
Diode Configuration
Single Diode Module
IF(av) @ 112 Deg C
100 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
2.02 kA
VF(to)
0.89V
Tj(max)
150°C
rF
2.05mΩ
I(gt) @ 25 Deg C
N/A
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
N/A
R th(j-c)
0.22°C/W
R th(c-h)
0.1°C/W
Weight
75g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
Product Datasheet
Alternatives
See ND89N14K or ND104N14K for Infineon Alternative
Westcode-IXYS-Littlefuse W0944WC150, Diode Capsule(PUK) 716 Amp, 1500V, 41/14
Features
Very low forward voltage drop
Very low leakage current
International standard package
41/14 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
DC Blocking Diode
UPS - Uninterruptible Power Supplies
Field Supply for DC Motors
Water Cooled Rectifiers
Large Generators
Specification
Westcode-IXYS-Littlefuse Part Number
W0944WC150
Vrrm
1500V
Diode Configuration
Diode Capsule (PUK)
IF(av) @ 100 Deg C
716 Amp
Package Size
ø41 x 14mm
Itsm
9 kA
VF(to)
0.79V
Tj(max)
180°C
rF
0.342mΩ
Gate Terminals
N/A
R th(jk) (double sided cooled 180°sin)
0.09°C/W
R th(c-h) (double sided cooled)
N/A
Weight
140g
Clamping Force
3.3 - 5.5kN
Factory Pack Qty
12
Certification
ROHS
IXYS - Westcode Headquarters
USA - UK
Datasheet
Product Datasheet
Alternatives
D770N20T
D770N16T
Heatsink
Heatsink Profiles
IXYS-Westcode-Littlefuse W2058LC140, Diode PUK 1508 Amp @ Tc = 100°C, 1400V 58/26 Rectifier Diode Capsule
Features
Very low forward voltage drop
Very low leakage current
International standard package
58/14 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Westcode-IXYS Part Number
W2058LC140
Vrrm
1400V
Diode Configuration
Diode Capsule (PUK)
IF(av) @ 100 Deg C
1508 Amp
Package Size
ø58 x 14mm
Itsm
19.5 kA
VF(to)
0.79V
Tj(max)
175°C
rF
0.192mΩ
Gate Terminals
N/A
R th(j-c) (double sided cooled 180°sin)
0.033°C/W
R th(c-h) (double sided cooled)
0.00°C/W
Weight
340g
Clamping Force
10 - 20kN
Factory Pack Qty
12
Certification
ROHS
IXYS Headquarters
USA
Datasheet
Product Datasheet
Alternatives
Contact Us for Possible Replacement
Heatsink
Heatsink Profiles
Crouzet Automation 84872130, Single Phase Multi-Function Voltage Control Relay Under/Overvoltage Detection with Latching(Memory) Function - 35 mm HUH, 15-600 VAC/DC Measurement, 24/240 VAC/DC Supply
For under and overvoltage monitoring of Single phase AC or DC Voltages up to 600V
Features:
Control of AC and DC voltages
Automatic recognition of AC/DC
Measurement ranges from 15 V to 600 V
Choice between under and overvoltage
True RMS measurement
Selectable latching (memory) function
Specification
Crouzet Part Number
84872130 (Single Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts)
Function
Undervoltage/Overvoltage
Nominal Voltage
1 x 15 - 600 VAC/DC
Digital Outputs
2 x C/O Relays, 250VAC/DC @ 8 Amp
Min Breaking Current
10mA/5VDC
Delay on Threshhold Crossing
0.1 → 3s (0, +10%)
Delay on Pickup
600ms
Alarm Delay on Time (max)
200ms
Reset Time
1500ms
Adjustable Hysteresis
5 - 50% of Threshhold
Maximum Measurement Cycle Time
30ms/True RMS Measurement
Measurement Accuracy
1%
Supply Voltage Range
Same as Measurement
Termination Style
Screw
Weight
170g
Certification
CE, UL, CSA, GL, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Range Overview HU Series
Perspex Cover for F Series Power Controllers up to 100 Amp
See the following brochures for dimensions of each controller
F330 Brochure
F431 Brochure
F430 Brochure
Perspex Cover for F Series Power Controllers 120-340 Amp Power Controllers
See the following brochures for dimensions of each controller
F330 Brochure
F431 Brochure
F430 Brochure