Eastron SDM630Modbus-MID-V2-GROWATT-SOLAX, DIN Rail Mount kWh Meter, 3 Phase, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved, Special 100mS Communication response time
Special 100mS Communication response time
3 x 100 amp Direct Connect
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
2 x Pulse Outputs (1 Configurable)
Â
The meter is intended for measuring, and monitoring single-phase or 3 phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Part Number
SDM630Modbus-MID-V2-GROWATT-SOLAX
Functions
Three Phase Energy Meter
Supply Voltage
NA
Nominal Measurement Range
415V L-L 230V L-N, 100 Amp
Maximum Measurement Range
480V L-L 230V L-N, 100 Amp
Nominal Current Input
Direct connect 3 x 100 Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (Special 100ms Response version)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
User Manual
Modbus Protocol
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Â
Fastron Electronics FAT100D420, AC Current Transducer, 100Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%
Features
Quick Release 24mm Split Core System
Cale Mount
4-20mA Output
24VDc Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
FAT100D420
Technology
24mm Split Core AC Current Transformer
Ratio
100/4-20mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
4-20mA (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
BH-100-1-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-100 Amp DC, +/-10VDC Bipolar or 0-10V Bipolar Analogue Output
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 0-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
RODN604025, Steel Enclosure, 600mmH x400mmW x 250mmD, IP66, RAL 7035 Gray 1.5mm Galvanised Steel
Features
Injected Polyurethane Sealing gasket
3 x M20 cable glands
4pcs Wall Mounts and dynabolts included
Lockable Door via Key
RAL7035 GREY AS3000/AS3100 Compliant
IP66
Â
Specification
Fastron Part Number
RODN604025
Function
Steel Water Proof Enclosure
Configuration
Enclosure with Hinged Door, Key Lock, 4 Mounting Clips, DYnabolts, and Cable Glands
Termination Style
Screw
Dimensions
H:600 x W:400 x D:250mm
Weight
15.6kg
Certification
AS 3000
AS 3100
Factory Pack Qty
1
Material of housing
1.5mm Galvanised Steel Painted RAL 7035
Enclosure protection
IP66
Operating Temperature
-20...55 °C
Datasheet
Datasheet
FPT-100 1500/5A 5P20 5VA, Protection Class CT, 1500/5A, Class 5P20 15VA, 103 x 64mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
Specification
Fastron Electronics Part Number
FPT-100 1500/5A 5P20 5VA
Technology
Protection Class Current Transformer
Ratio
1500/5
Aperture Size
103 x 64mm
VA Rating
15VA
Accuracy Class
Class 5P20
Output
5 Amp AC
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10 Deg C / 50 Deg C
Continuous Current (max)
1500Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
1.5 kg
Factory Pack Qty
1
Datasheet
Product Installation Guide and Datasheet
FSQF480D60, Solid State Relay, 3 Phase 4-32VDC Control, 60Amp, 24-530VAC Load, IP20
Ratings from 25 to 80 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage turn-on
IP20 Cover Integrated
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Trent Part Number
FSQF480D60
Switching Type
Zero Crossing
ROHS/CE
Yes
Control Voltage
4-32VDC
Load Current
60 Amp (rms) per Phase
Surge Capability
700 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
24-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
530g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Equivalent Parts
Contact Us for Possible Replacement
Â
Fastron Electronics FESCTHY-51-1000-100mA, 1000Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Electronics Part Number
FESCTHY-51-1000-100mA
Technology
Split Core AC Current Transformer
Ratio
1000/100mA
Aperture Size
51 x 51mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mAAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
1000Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
950g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics SCT-F24-75-100mV, 75Amp/100mV Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
100mVÂ Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F24-75-100mV
Technology
Split Core AC Current Transformer
Ratio
75/100mV
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mVÂ (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
75Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics SCT-F24-100-100mV,100Amp/100mV Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
100mVÂ Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F24-100-100mV
Technology
Split Core AC Current Transformer
Ratio
100/100mV
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mVÂ (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FSQF480D25, Solid State Relay, 3 Phase 4-32VDC Control, 25Amp, 24-530VAC Load, IP20
Ratings from 25 to 80 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage turn-on
IP20 Cover Integrated
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Trent Part Number
FSQF480D25
Switching Type
Zero Crossing
ROHS/CE
Yes
Control Voltage
4-32VDC
Load Current
25 Amp (rms) per Phase
Surge Capability
300 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
24-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
385g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Equivalent Parts
Contact Us for Possible Replacement
Â
Fastron FTCK-6-400-XX-KSE, Type K Thermocouple MIMS Class A, 400mm Probe Length, 6mm Shaft Diameter w/ SMALL Terminal Head, -20 to 500 Deg C, KSE(wire entry:M16x1.5, probe entry: G1/2'')
Type K MIMS Thermocouple
Class A Accuracy
Powder Coated Die Cast Alloy Terminal Head
Low Long Term Drift
Rated for -20 to 500 Deg C Max
Spring Cable Connection
3 or 6mm or Custom
304 SS Sheath
Recommended to use BSP Fitting for mounting
Specification
Fastron Part Number
FTCK-6-400-XX-KSE
Sensor Type
Type K Thermocouple
No of Wires
2
Probe Length
400mm
Sheath Thickness
6mm
Sheath Material
SS 304 Stainless Steel
Accuracy
Class A
Approvals
CE, ANSI, ROHS
Cable length
Small Terminal Head (105 x 70mm)
Terminal Head Type
Small Powder Coated Die Cast Alloy (Weather Proof), , KSE(wire entry:M16x1.5, probe entry: G1/2'')
Temperature Range
-20 to 500 Deg C
Special Feature
Small Terminal Head
Mounting Style
BSP Bayonet or Flange Fitting Recommended
Weight
470-700g
Factory Pack Qty
1
Datasheet
Datasheet
Fastron Electronics FESCT-055-250-1-IP65, 250Amp Measurement, 1 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 55mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 1 Amp Outputs
Â
Specification
Fastron Electronics Part Number
FESCT-055-250-1-IP65
Technology
Split Core AC Current Transformer
Ratio
250/5A
Aperture Size
ø 55mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
250Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide