Crydom CWA4890P, Solid State Relay, Single Phase 90-280VAC Control, 90A, 48-660VAC Load w/ Overvoltage Varistor
Features
Ratings from 25A to 125 Amp @ 48-660VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CWA4890P
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
24VAC (18-36VAC)
Load Current
90 Amp (rms)
Surge Capability
1350 Amp (peak)
Special Feature
LED Status Indicator, High Surge, MOV Overvoltage protection
Mounting Style
Panel Mount
Load Voltage Range
48-660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HA48125, Solid State Relay, Single Phase 90-280VAC Control, 125A, 48-530VAC Load
Features
Ratings from 25A to 125 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HA48125
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90-280VAC
Load Current
125 Amp (rms)
Surge Capability
1670 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics FAT300D10, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 0-10V Average RMS Output, Accuracy = 1%, 500mm Cable Length
Features
Quick Release 24mm Split Core System
Cale Mount
0-10V Output
24VDC Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FAT300D10
Technology
24mm Split Core AC Current Transformer
Ratio
300/0-10V
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0-10V (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
300Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics FAT100D10, AC Current Transducer, 100Amp Measurement, 24mm Split Core, 0-10V Average RMS Output, Accuracy = 1%, 500mm Cable Length
Features
Quick Release 24mm Split Core System
Cale Mount
0-10V Output
24VDC Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FAT100D10
Technology
24mm Split Core AC Current Transformer
Ratio
100/0-10V
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0-10V (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics GT-AV(0-230)-A-VO(0-5), AC Voltage Transducer, 0-230V AC input, 100-240VAC/DC aux, 0-5V Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-230)-A-VO(0-5)
Control Output
0-5V Average RMS
Input
0-230VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics AMB-M-A9-A-N, 96 x 48mm AC Ammeter, True RMS, 0-10 Amp Input, 110-240VAC Aux supply, Large 4.1 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 4.1 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
90mm Depth
CE Approved
Specification
Fastron Electronics Part Number
AMB-M-A9-A-N
Conditioner Output
N/A
Input
0-10 Amp AC True RMS
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
110 - 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
4.1 Digit RED LED
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet NEW Version
Application Notes
Panel Meters Blog Articles
H42 Heatsink Profile 33mm x 98mm, Various Lengths cut to order, Milled or Raw Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
Crydom H12D4840D, Dual Solid State Relay, Two Pole 3-15VDC Control, 2 x 40A, 48-530VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
H12D4840D
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
3-15VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR, 1200V Transient Withstand
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
faston
Unit Weight
89g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See CC4850W3VH
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom Series 1 HA4875, Solid State Relay, Single Phase 90-280VAC Control, 75A, 48-530VAC Load
Features
Ratings from 25A to 125 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HA4875
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90-280VAC
Load Current
75 Amp (rms)
Surge Capability
954 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
HA4890
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom D2475, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load
Features
• Ratings from 25A to 125 Amp @ 24-280 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
D2475
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
40 Amp (rms)
Surge Capability
954 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Please note Changes from Gen 3 to Gen 4 (current) package design here
Alternatives
See HD48125 or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics FAT300D420, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%
Features
Quick Release 24mm Split Core System
Cale Mount
4-20mA Output
24VDc Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FAT300D420
Technology
24mm Split Core AC Current Transformer
Ratio
300/4-20mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
4-20mA (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
300Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide