Search results for "비대면유심개통문의 gora43430aa 소액대출50만원내구제 고라통신 선불유심 현금화 정식업체 무서류간편대출 은평구 24시 당일소액급전대출"
-
11125349, Regulator for AAK4986 11.125.349 MAHLE Alternator
Heavy Item - No Free ShippingISKRA LETRIKA 11125349, Regulator for AAK4986 11.125.349 MAHLE Alternator OEM MAHLE(Letrika) 11125349 Specification ISKRA (MAHLE) Part Number 11125349 ISKRA/LETRIKA/MAHLE 11125349
-
84871130, AC/DC Current Monitoring Relay Selectable Over/Under Current with Latching Single Phase 0.1 - 10 Amp EIH Series, 24-240VAC/DC Supply, Under/Over
Free Aus Post Shipping for $300 SpendCrouzet Automation 84871130, AC/DC Current Monitoring Relay Selectable Over/Under Current with Latching Single Phase 0.1 - 10 Amp EIH Series, 24-240VAC/DC Supply, Under/Over For Current Monitoring of AC Current from 0.1 Amp to 10 Amp. Features: 0.1 to 10 Amp Trip Range 0 to 100% Hysteresis True RMS measurement Selectable Latching with Memory Function Specification Crouzet Part Number 84871130 (AC/DC C-Lynx Current Monitoring Relay With DPDT Contacts, latching and memory) Function Current Threshold Montoring Nominal Current 0.1- 10 Amp AC Digital Outputs 2 x C/O Relays, 24-240VAC/DC @ 5 Amp Min Breaking Current 10mA/5VDC Delay on Threshhold Crossing 0.1 → 3s (0, +10%) Delay on Pickup 600ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Adjustable Hysteresis 5 - 50% of Threshhold Maximum Measurement Cycle Time 30ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range 24VAC/DC 48VAC 120/220VAC +/-15% Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
11.131.862 AZF4229 MAHLE - Letrika(Iskra) Starter Motor, 12VDC
Heavy Item - No free ShippingISKRA LETRIKA (MAHLE) 11.131.862 AZF4229 - Letrika(Iskra) Starter Motor, 12VDC OEM MAHLE(Letrika) 11131862 Letrika AZF4229 Iskra IS1237 MAHLE MS 67 Specification ISKRA (MAHLE) Part Number 11.131.862 AZF4229 ISKRA/LETRIKA/MAHLE 11.131.862 AZF4229 IS1237 MS 67 Voltage 12VDC Power 4kW No of Pinon Teeth 9 Module 3mm Unit Weight 4.7kg Factory Pack Qty 1 Applications ManufacturerVehicleTypeEngineLtrDateAHLMANN (MECALAC)AL100BF4L2011-AHLMANN (MECALAC)SYSTEM 180 (SWING)AZ90tBF4L2011; 53kW-ATLAS COPCOXAS66Deutz F3M101101.97-ATLAS COPCOXAS66DDGDeutz F3M1011F01.97-BOMAGBW120ADDeutz F2L1011F01.97-CASETRENCHERS360Deutz Engine01.88-01.98CHAMPIONROLLERSA421 Super PacDeutz F3L1011F01.96-DEUTZ AG (KHD)D2011L4D2011 L4; 4-cyl-DEUTZ AG (KHD)TCD2011 L44 cyl3.6-DEUTZ AG (KHD)TD2011 L4W3.6-DYNAPAC (ATLAS COPCO GROUP)DOUBLE DRUM VIBR. ROLLERSCG233HFTCD2011 L04W; 4-cyl; 65kW3.6-DYNAPAC (ATLAS COPCO GROUP)DOUBLE DRUM VIBR. ROLLERSCG333HFBF4M 2011 L04W; 4-cyl; 62kW3.6-DYNAPAC (ATLAS COPCO GROUP)DOUBLE DRUM VIBR. ROLLERSCG333HFTCD2011 L04W; 4-cyl; 65kW3.6-EUROMACCHINEMOTOR PUMPSMP 01 DCBF4M2011; 4-cyl; 52kW3.1-EUROMACCHINEMOTOR PUMPSMP 02 DCBF4M2011; 4-cyl; 52kW3.1-EUROMACCHINEMOTOR PUMPSMP 03 DCBF4M2011; 4-cyl; 77,5kW4.0-EUROMACCHINEMOTOR PUMPSMP 04 DCBF4M2011; 4-cyl; 77,5kW4.0-GEHLSKID STEER LOADERS5640BF4M2011; 4-cyl; 60kW3.1-GEHLSKID STEER LOADERS5640F4M2011; 4-cyl; 45kW3.1-JCBWHEELED LOADING SHOVELS409Deutz TD2011 L4; 75HP3.6-JLGARTICULATING BOOM LIFTS600AF4M1011F-JLGTELESCOPIC BOOM LIFTS600SF4M1011F01.96-KRAMERFARM TELE WHEEL LOADERSKL27TD2011 L04; 45kW3.6-KRAMERFARM TELE WHEEL LOADERSKL35TD2011 L04; 55kW3.601.12-KRAMERFARM WHEEL LOADERSKL35D2011 L04; 45kW3.6-KRAMERFARM WHEEL LOADERSKL37D2011 L04; 55kW3.6-KRAMERFARM WHEEL LOADERSKL43D2011 L04; 55kW3.6-KRAMERWHEEL LOADERS1150D2011 L04W; 4-cyl; 55kW3.6-KRAMERWHEEL LOADERS380D2011 L04W; 4-cyl; 45kW3.6-KRAMERWHEEL LOADERS480; 480TD2011 L04W; 4-cyl; 45kW3.6-KRAMERWHEEL LOADERS580TCD2011 L04W; 4-cyl; 55kW3.6-KRAMERWHEEL LOADERS680TTCD2011 L04W; 4-cyl; 55kW3.6-KRAMERWHEEL LOADERS750; 750TD2011 L04W; 4-cyl; 45kW3.6-KRAMERWHEEL LOADERS780D2011 L04W; 4-cyl; 55kW3.6-KRAMERWHEEL LOADERS850D2011 L04W; 4-cyl; 45kW3.6-KRAMERWHEEL LOADERS950TCD2011 L04W; 4-cyl; 55kW3.6-PORTAFILLSCALPING SCREENSMR-5TD2011 L4; 41kW Tier 33.6-PORTAFILLTROMMEL SCREENSMT-5TD2011 L4; 41kW Tier 33.6-WACKER NEUSONCOMPACT EXCAVATORS14504TCD2012-L04 2V; 4-cyl; 75kW4.0-WACKER NEUSONCOMPACT EXCAVATORS9503TCD2012-L04 2V; 4-cyl; 75kW4.0-WACKER NEUSONWHEEL DUMPERS10001D2011T; 4-cyl; 65kW; Tier 33.6-WACKER NEUSONWHEEL DUMPERS6001D2011T; 4-cyl; 65kW; Tier 33.6-WACKER NEUSONWHEEL DUMPERS9001D2011T; 4-cyl; 65kW; Tier 33.6-WACKER NEUSONWHEEL LOADERWL 37TD2011 L04W; 4-cyl; 55kW3.6-WACKER NEUSONWHEEL LOADERWL 48TD2011 L04W; 4-cyl; 45kW3.6-WEIDEMANNTELE WHEEL LOADERS2070 CX80 LP TTD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNTELE WHEEL LOADERS2070 CX80 TTD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNTELE WHEEL LOADERS3070 CX60 LP TTD2011 L04W; 4-cyl; 45kW3.6-WEIDEMANNTELE WHEEL LOADERS3070 CX60 TTD2011 L04W; 4-cyl; 45kW3.6-WEIDEMANNTELE WHEEL LOADERS3070 CX80 LP TTD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNTELE WHEEL LOADERS3070 CX80 TTD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNTELE WHEEL LOADERS4070 CX80 TTD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNWHEEL LOADERS2070 CX80TD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNWHEEL LOADERS2070 CX80 LPTD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNWHEEL LOADERS3070 CX60TD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNWHEEL LOADERS3070 CX60 LPTD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNWHEEL LOADERS3070 CX80TD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNWHEEL LOADERS3070 CX80 LPTD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNWHEEL LOADERS4070 CX80TD2011 L04W; 4-cyl; 55kW3.6-WEIDEMANNWHEEL LOADERS4070 CX80 LPTD2011 L04W; 4-cyl; 55kW3.6- Cross Applications Reference MAHLE Letrika Website Spare Parts MAHLE Letrika Website
-
DRA1-MPDCD3, Solid State Relay 3-32VDC control, 60V, 3A DC Load, DIN Rail
Free Aus Post Shipping for $300 SpendCrydom DRA1-MPDCD3, Solid State Relay 3-32VDC control, 60V, 3A DC Load, DIN Rail Features Ratings up to 3 Amp @ 60VDC, or 4 Amps @ 280VAC DIN Rail Mount Mosfet output for reliable DC switching, SCR for AC Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Redesigned housing with anti-rotation barriers EMC compliant to Level 3 Epoxy free design Spec Crydom Part Number DRA1-MPDCD3 Switching Type DC Load ROHS Yes (Details) Control Voltage 3-32VDC Load Current 3 Amp DC Surge Capability (10ms) 5 Amp DC Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 0 - 60VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 35g Factory Pack Qty 20 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
E53TP25C, Solid State Relay, 3 Phase 18-36VAC Control, 25A, 48-530VAC Load, LED Status Indicator, IP20
Free Aus Post Shipping for $300 SpendCrydom E53TP25C, Solid State Relay, 3 Phase 18-36VAC Control, 25A, 48-530VAC Load, LED Status Indicator, IP20 Features Ratings from 25A to 50 Amp @ 70-480 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number E53TP25C Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 18-36VAC Load Current 25 Amp (rms) per Phase Surge Capability 239 Amp (peak) Special Feature LED Status Indicator Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
PNC113FDA, Normally Closed DC Contactor SPST-NC, 50 AMP, 1200VDC, 48VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals
Free Aus Post Shipping for $300 spendGigavac PNC113FDA, Normally Closed DC Contactor SPST-NC, 50 AMP, 1200VDC, 48VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals Features Perfect for Capacitor Discharge or Dump Switch Applications Hermetically Sealed (Patented) rated to 175 Deg C High Efficiency Dual DC Coils - 12,24,48VDC options Ideal for battery powered systems or where low power is needed Built in Coils suppression for all DC Coils Small and lightweight Flexible package for installation CE Approved Specification Gigavac Part Number PNC113FDA Main Contact Type SPST-NC Auxiliary Contact Type N/A Coil Voltage 48VDC Load Current 50 Amp Mechanical Life @ 0 Amp 50,000 Operations Impulse Withstand 6kV rms Control Input Terminals M3 Screw Special Feature N/A Mounting Style Panel Mount (M4) Load Voltage Range 1500VDC Standards CE Approved Termination Style M4 Screw Unit Weight 135g Factory Pack Qty 1 Datasheet Product Datasheet
-
GV211CAX, Contactor SPST-NO, 150+ AMP, 12-900VDC, 24VDC Coil, 38cm Flying leads, IP67, IP69
Free Aus Post Shipping for $300 spendGigavac Sensata GV211CAX, Contactor SPST-NO, 150+ AMP, 12-900VDC, 24VDC Coil, 38cm Flying leads, IP67, IP69 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Gigavac Part Number GV211CAX Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 24VDC Load Current 150+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 12 - 900VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 250g Factory Pack Qty 1 Datasheet Product Datasheet
-
D2440-10, Solid State Relay, Single Phase 3-32VDC Control, 40A, 24-280VAC Load, Random Crossing
Free Aus Post Shipping for $300 SpendCrydom D2440-10, Solid State Relay, Single Phase 3-32VDC Control, 40A, 24-280VAC Load, Random Crossing Features • Ratings from 25A to 125 Amp @ 24-280 VAC • SCR output for heavy industrial loads • Zero voltage or instantaneous turn-on outputs • UL/CSA/VDE Approved, CE Compliant to EN60950-1 • Improved SEMS screw and washer • Redesigned housing with anti-rotation barriers • AC & DC control types • Direct bond copper substrate • EMC compliant to Level 3 • Direct power lead frame • Epoxy free design Spec Crydom Part Number D2440-10 Switching Type Random Crossing ROHS Yes (Details) Control Voltage 3-32VDC Load Current 40 Amp (rms) Surge Capability 597 Amp (peak) Special Feature None Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Please note Changes from Gen 3 to Gen 4 (current) package design here Alternatives See D2450-10 or D2475-10 which are stocked items App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
MOD2 3NL 250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 27kA 250 Amp, 400/690VAC
Free Aus Post Shipping for $300 SpendIskra Doo MOD2 3NL 250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type Icu = 36kA, Ics = 27kA 250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MOD2 3NL 250A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current Icu = 36kA, Ics = 27kA, @ 400VAC, Icu =20kA @ 690VAC Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
G18WP, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G18WP, HV Relay, 15kV, 30A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G18WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 30 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
KNL63-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO with 1 x NO 1 x NC Aux Contacts, Nominal Current = 63 Amps, 24VAC Coil
Free Aus Post Shipping for $300 SpendIskra Doo KNL63-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO with 1 x NO 1 x NC Aux Contacts, Nominal Current = 63 Amps, 24VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL63-11-24VDC Functions 3 Pole Contactor (3 x NO, with 1 x NO, 1 x NC Aux Contacts) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 63 Amp Continuous @ 55 Deg C Auxiliary Contacts 3 x NO, with 1 x NO, 1 x NC Aux Contacts (6 Amp) Trip Delay Time 2-10ms Electrical Life 500,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VAC Power Dissipation 6W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 950g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
SDM630MCT-MODBUS-MID-CL1 V2, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms
Free Aus Post Shipping for $300 SpendEastron Europe SDM630MCT-MODBUS-MID-CL1 V2, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 0.333V CT Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms 1/5 Amp CT Input RS 485 communication up to 38,400 bit/s as standard Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-MODBUS-MID-CL1 V2 Functions Three Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 1/5 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Setup Video - CT Ratio Unlock Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility