Magnelab DCT-0010-025, AC CT, Self Powered, 25 Amp Average RMS 0-5V output
Features
Split Core
0-5V Average RMS Output
Cable Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀ 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
Magnelab Part Number
DCT-0010-025
Technology
AC Current Transformer
Supply Voltage
Self Powered
Load Current (RMS)
25 Amp
Maximum Measurement Current (RMS)
37.5 Amp
Output
0-5V (Average RMS) 5% Ripple
Response Time
300ms
Isolation
2.5kV (AC, 50Hz, 1 min)
Voltage Rating
Cat III 600VAC
Bandwidth
50/60Hz
Mounting Style
Cable Mount
Operating Temperature Range
-20°C / 50°C
Accuracy
2%
Aperture
⌀ 10mm
Termination Style
Screw
Approvals
CE,UL,ROHS2
Unit Weight
70g
Factory Pack Qty
6
Datasheet
Product Datasheet
Rishabh CT 300/5 Class 0.5 5VA 50/30 (30) 300/5 Amp Current Transformer 5VA, Class 0.5
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 300/5 Class 0.5 5VA 50/30 (30)
Technology
AC Current Transformer
Ratio
300/5
Aperture Size
⌀ 26mm or 30x10mm Busbar
VA Rating
5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
300Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
LEM LV 25P/SP5, C/L Hall Effect Voltage Sensor 10mA@10-500V, 25mA Output
Features
Bandwidth DC to 25kHz
Multi Range through pin selection
Closed loop transducer using Hall effect
Compact and versatile
PCB Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LV 25-P/SP5
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Primary Nominal Current (RMS + DC)
10 mA
Measurement Range
10 - 700V (0 -14mA)
Output
25 mA
Isolation
2.5 kV
Bandwidth
DC-25 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 90°C
Accuracy
0.9%
Termination Style
Through Hole PCB
Unit Weight
22g
Factory Pack Quantity
25
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
LEM HTA 100-S, O/L Hall Effect Current Sensor, 100 Amp, +/-4V Output
Features
Bandwidth DC to 50kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, 100 to 1000 A in one package.
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
HTA 100-S
Technology
Open Loop Hall Effect
Aperture
ø32mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
100 Amp
Measurement Range
+/-300 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC-50 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 80°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
230g
Factory Pack Quantity
10
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
RCS-3600-5000 0.333V, 3 Phase 5000Amp AC Measurement 12 Inch Rogowski Coils with Integrator, Class 1
The RCS-3600 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-3600 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Â
Specification
Magnelab Part Number
RCS-3600-5000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
5000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 3000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Fastron Electronics SCT-F16-20-1A, 20/1Amp Measurement, Class 1 Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F16-20-1A
Technology
Split Core AC Current Transformer
Ratio
20/1A
Aperture Size
ø 15 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
20Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
Crouzet 88975111, Millenium EVO Ethernet, Smart Relay with Display, 24 I/O, 24VDC, 8 Configurable Analogue/Digital Inputs, 4 x High Speed 15kHz Inputs, 4 x Std Digital Inputs, 2 x 6 Amp Relay, 6 x 8 Amp Relay
Up to 44 I/Os - 16 DI (4 HighSpeed / 8 AI) - 8 DO
Wireless programming & Control with bluetooth Interface and Crouzet Virtual Display
Modbus RTU Network (Slave)
Local datalog management
Up to 1000 programing blocks with intuitive Crouzet Soft to go from simple to complex applications
HMI Screens Available
Specification
Crouzet Part Number
88975111 (Millenium EVO)
Analogue Inputs
0 - 10VDC, 0-V Power Supply or Voltmeter
Digital Inputs
24VDC @ 2.1mA (8 Standard and 4 High Speed)
Digital Outputs
Relay, 24VDC, 250VAC @ 100mA minimum (2 x 6 Amp, 6 x 8 Amp)
PWM SSR Output
None
Expandable
Yes
Comms
Ethernet. (RS485, Bluetooth). Standard and Wifi versions available
LCD Display
Yes
Mounting Style
DIN Rail Mount (124.6mm)
Supply Voltage Range
24VAC (21.6 - 28.8VAC)
Termination Style
Screw
Weight
350g
Environmental
Reach, RoHS, Halogen free 1272/2008/CE
Certification
CE, cULus Listed
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Â
Datasheet
Product Datasheet
Launching Note
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Fastron Electronics FAT200D420T, AC Current Transducer, 200Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%
Features
Quick Release 24mm Split Core System
Cale Mount
4-20mA Output
24VDc Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
FAT200D420T
Technology
24mm Split Core AC Current Transformer
Ratio
200/4-20mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
4-20mA (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
DC-0-5-010-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 0-10V Bipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-5 Amp DC, 4-20 mA Bipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Bipolar Measurement
0-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-5-010-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-5 Amp
Response Time
< 1uS
Output
Bipolar 0-10V
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
LEM LF 2005-S/SP6, C/L Hall Effect Current Sensor, 2000 Amp Input, 400mA Output, +/-15/24VDC Power Supply
Features
Bipolar and insulated current measurement up tp 3000 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LF 2005-S/SP6
Technology
Closed Loop Hall Effect
Aperture
ø60.5mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
2000 Amp
Measurement Range
+/- 3000 Amp
Output
400 mA
Isolation
6 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.3%
Termination Style
Custom Connector (details provided on request)
Unit Weight
1.5kg
Factory Pack Quantity
9
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
Fastron Electronics SCT-F50-800-40mA, 40mAmp, 800Amp Measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F50-800-40mA
Technology
Split Core AC Current Transformer
Ratio
800/100mAmp
Aperture Size
ø 50 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
800Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
1000g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron Electronics SCT-F50-500-40mA, 40mAmp, 500Amp Measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
40mA Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F50-500-40mA
Technology
Split Core AC Current Transformer
Ratio
500/40mAmp
Aperture Size
ø 50 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
40mA Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
800Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
1000g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's