Trent NBR-A069UD33LI450, Semiconductor Fuse, 450 Amp, 690VAC, Size_Body Size 33 Type KI, 200kA with Indicator and Microswitch
Features
Square Body Size_Body Size 33 Type KI
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Fuse Blown Indicator and Microswitch
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-A069UD33LI450
Fuse Type
I²t AR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (660V)
87000A²/s
Nominal Current (RMS + DC)
450 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
134 x 73 x 78.5mm
Hole Centers
91.5mm +/- 16.1mm
Mounting
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
95W
Termination
M10
Unit Weight
350g
Factory Pack Qty
10
Datasheet
Product Datasheet
Trent NBR-A070UD33LI800, Semiconductor Fuse, 800 Amp, 690VAC, Size_Body Size 33 Type KI, 200kA with Indicator and Microswitch
Features
Square Body Size_Body Size 33 Type KI
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Fuse Blown Indicator and Microswitch
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-A070UD33LI550
Fuse Type
I²t AR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (660V)
155000A²/s
Nominal Current (RMS + DC)
550 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
134 x 73 x 78.5mm
Hole Centers
91.5mm +/- 16.1mm
Mounting
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
110W
Termination
M10
Unit Weight
900g
Factory Pack Qty
10
Datasheet
Product Datasheet
Trent NBR-A070UD33LI900, Semiconductor Fuse, 900 Amp, 690VAC, Size_Body Size 33 Type KI, 200kA with Indicator and Microswitch
Features
Square Body Size_Body Size 33 Type KI
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Fuse Blown Indicator and Microswitch
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-A070UD33LI900
Fuse Type
I²t AR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (660V)
770000A²/s
Nominal Current (RMS + DC)
900 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
134 x 73 x 78.5mm
Hole Centers
91.5mm +/- 16.1mm
Mounting
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
135W
Termination
M10
Unit Weight
900g
Factory Pack Qty
10
Datasheet
Product Datasheet
Magnelab HCT-0036-500, Split Core DC Hall Effect Current Sensor, 500 Amp, +/-4V Output, Split Core 36mm Aperture, X = 1%
Features
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
Magnelab Part Number
HCT-0036-500
Technology
Split Core Open Loop Hall Effect
Aperture
ø36mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
500 Amp
Measurement Range
+/-750 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 75°C
Accuracy
1%
Termination Style
Flying Lead
Unit Weight
400g
Factory Pack Quantity
10
Datasheet
Product Datasheet
Secure Meters DPM48I150-2, 48mm x 96mm LCD Digital Ammeter, 0-6 Amp Input, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM48I150-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
0-6 Amp
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030
Protection Degree
IP54 (IP65 Optional)
Weight
280g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
Secure Meters DPM48V150-2, 48mm x 96mm LCD Digital Voltmeter, 57.5-250VAC Input, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM48V150-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
57.5 - 250VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030
Protection Degree
IP54 (IP65 Optional)
Weight
280g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
Secure Meters DPM96I360-2, 96mm x 96mm LCD Digital AC Ammeter, 3 Phase 0-6 Amp CT Inputs, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM96I360-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
0-6 Amp 3 Phase CT inputs
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030
Protection Degree
IP54 (IP65 Optional)
Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
SSP-BLUE-4mm (2pcs), Blue 4mm Fully Sheathed Safety/Banana Plugs, 32 Amp, 1000V Rated. For Test Equipment/Leads (Current Clamps)
4mm
Fully Sheathed
Suitable for M1/M2 or other 4mm Current Clamps
32 Amp / 1000V AC (rms) or DC Maximum Rating
Premier 211-PT5A0-GJO+5581901, Three Phase Market Grade Revenue Meter for Small Commercial Applications, 5-20 Amp CT Connect, NMI 6
Three Phase Market/Revenue Grade Meter for small commercial applications
Usage
The meter is intended for measuring, monitoring three-phase electrical power network in residental, or small commercial applications for billing purposes. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Specification
Secure Part Number
Premier 211-PT5A0-GJO+5581901
Functions
Commercial Billing Meter with LCD Display
Nominal Measurement/Supply Range
3 x 2300/460VAC, 5-20 Amp 50Hz
Maximum Measurement Range
460VAC, 10/100 Amp 50Hz
4 Quadrant Measurement
Import/Export
Tariff Input
N/A
Accuracy
Class 1
Comms
N/A Optional Addon Module
Weight
2000g
Certification
CIEC/AS 62052-11, IEC/AS 62053-21, NMI M6-1
Factory Pack Qty
1
Safety
IP53
Enclosure Material
Engineering Plastic
Optional
RTC,Load Profile, RS485 Interface, Outputs
Operating Temperature
-40 →+80 °C
Datasheet
Datasheet
User Manual
IGC meters
MT860
MT830/831
ICG Meter Shortform
Crydom CN240A24, Slimline Relay, 15-30VDC Coil, 2 Amp 24-280VAC Load
Features
Output 2Amp @ 250VAC
15-30VDC Control input
DIN Rail Mount
Changeover Contact
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
CN240A24
Switching Type
250VAC 2 Amp Load SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
15-30VDC
Load Current
2 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
250VAC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Datasheet
Relay Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket
Crydom CN024D05, Slimline Relay, 3-12VDC Coil, 24VDC 3.5 Amp Load
Features
Output 3.5Amp @ 24VDC
3-12VDC Control input
DIN Rail Mount
Changeover Contact
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
CN024D05
Switching Type
24VDC 3.5 Amp Load SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
3-12VDC
Load Current
3.5 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
24VDC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Datasheet
Relay Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket
Iskra Doo SQ0214 L230V RC S6SS Synchroscope (Synchronoscope)
Measurement of phase difference between bus bar and generator
Five instruments in one (SQ 0x14)
Circular display of ∆ phase difference
Magnifield display of phase difference ∆ = ±20
Microprocessor processing
Simple synchronization conditions setting
Output relay for synchronisation (pulse or continuous)
''Dead busbar or generator'' functionality
Power supply from bus bar or generator
Standard 96x96 mm or 144x144 mm din housing
LCD with backlight for voltage, frequency and/or ∆ monitoring (SQ 0x14 only)
High immunity to EMC disturbances
Special functions set with three jumpers inside the instruments Status output
Green led for indication of both voltages
Ship version (Bureau veritas certificate - SQ 02x4)
Specification
Iskra Doo Part Number
SQ0214 L230V RC S6SS
Function
Phase Difference (∆ϕ) Measurement
Nominal Voltage (Un)
230VAC ± 20 % Line to Line (UL-N = 400 VMAX) @ 40-70Hz
Digital Output
Relay 250 V, 1 A, 50 Hz, 250 VA
Status Output
Open-Collector 24 Vdc + 20% @30mA
Switch On Delay Time Range
0,1 ... 1 s +/-10%
Phase Difference Setting Range
2 ... 20 °el ± 3 °el
Voltage Difference Setting Range
1 ... 10 % +/-2.5%
Dead Busbar Noise Rejection Range
10%, 20%, 30% or 40%
Power Consumption
< 4VA
Short Term Overload
2 x Un for 3 seconds
LCD Display Accuracy
Voltage 1.5%, Frequency 0.5%, Phase Difference +/-3 °el
Synchronisation Accuracy
+/- 10%
Termination Style
Screw
Weight
530g
Certification
CE
Factory Pack Qty
1
Enclosure Version
Ship Version
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP52 for case, IP20 for terminals with protective cover
Safety
According to EN 61 010-1 400 V, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Product Datasheet
User Manual
Application Notes & Software Downloads
The following parameters can be set via internal jumper see User Manual for more details.
Dead Busbar Generator Function
Over and Under Frequency Synchronising
Adjustable Lenght of a Sync Pulse
The following parameters Can be set via MIPack Comms Module & SQset Setting Software
Relay - 300mS/Continuous/Programmable
Dead Busbar - Active DB/Active DB + DG & % Threshold
MIPack User Manual
Download SQSet Settign Software