BH-50-2-24, Split Core Hall Effect DC Current Transducer, +/-50 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-50 Amp DC, 4-20mA Bipolar Output
Features
⌀31mm Aperture
Split Core
DC Bipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-50-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-50 Amp DC
Response Time
< 200mS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-100-1-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-100 Amp DC, +/-10VDC Bipolar or 0-10V Bipolar Analogue Output
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 0-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-100-2-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/100 Amp DC, 4-20mA Bipolar Output
Features
⌀31mm Aperture
DC Bipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
F19-271YF19-271Y-L, 19mm Pushbutton Switch Metal with YELLOW Ring Illumination, 1xNO 1xNC, 3 Amp (Nominal) 5 Amp (Max) @ 250VAC or 24VDC, 24VDC Illumination Supply, 0.05 Million Ops
Description
Pushbutton switch available in version Standard, Illuminated, with Point Illumination, 1xNO 1xNC, Lettering, varnished in different colours
Assembly by mounting with nut
Pin connections, Pins with Soldering Aid or Clip for Pins
Characteristics
Housing and actuator material types: zinc die-cast with nickel plating or stainless steel
Wide range of materials, colours, lettering, colours of illumination - Switching voltage max. 250VAC 30VDC, switching current max. 12 Amp
24VDC Illumination Supply Voltage
Zinc die-cast for housing and actuator For indoor use, no Illumination, 1xNO 1xNC, no lettering
Stainless Steel for actuator Optional point illumination and laser lettering with standard or customer-specific symbols
Stainless Steel for housing and actuator for use in harsh environments outdoors (see technical data)
Tamper Proof suitable for public spaces
Specification
Fastron Electronics Part Number
F19-271Y
Switch Size
20 x 19mm
Nominal Voltage
250VAC/DC
Rated Power
750W
Switch Type
Momentary1NO + 1NC
Illumination voltage
24VDC @ 10mA
Illumination type
YELLOW RING
Nominal Current (AC/DC)
3 Amp @240VAC/24VDC
Contact Resistance ON/OFF
<100m Ohm
Dimensions
ø22 x 14.6mm
Operating Temperature Range
-20°C / 85°C
Termination
Faston/Solder Pins
IP Protection Rating
(IP 67 with Oring) IP 64 (IP40 switching circuit)
Unit Weight
40g
Factory Pack Qty
10
Datasheet
Product Datasheet
Rishabh CT 100/5 Class 0.5 2.5VA 50/21 (50), Current Transformer, ⌀ 21mm or 20x10mm Busbar
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 100/5 Class 0.5 2.5VA 50/21 (50)
Technology
AC Current Transformer
Ratio
100/5
Aperture Size
⌀ 21mm or 20x10mm Busbar
VA Rating
2.5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Magnelab SCT-0400-005, 5 Amp, 0.333v Class 1 Series Current Transformer, 10mm Aperture, UL approved
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Magnelab Part Number
SCT-0400-005
Technology
Split Core AC Current Transformer
Ratio
5/0.333v
Aperture Size
ø 10 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
5Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Magnelab SCT-0400-001, 1 Amp, 0.333v Class 1 Series Current Transformer, 10mm Aperture, UL approved
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Magnelab Part Number
SCT-0400-001
Technology
Split Core AC Current Transformer
Ratio
1/0.333v
Aperture Size
ø 10 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
1Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
H37 (Semikron P35) Heatsink Profile 40mm x 250mm, Various Lengths cut to order, Milled or Raw Finish
Note: for Milled finish. we can mill 150mm each pass leaving a line in the centre.
Note: for any lengths not showing in stock, and we have longer lengths in stock, the profile is available in 2-3 days to cut and mill.
Datasheet
Product Datasheet
Trent DSTO-C20-6F-R-N-O-H, Distribution Unit with IEC Inlet C20 to 6 x F/C13 Outlet, 240VAC @ 16 Amp with Rocker Switch, Rear Mounted with Wings, MOQ = 10pcs (If not in stock)
Features
1 x C20 in 6 x F/C13 out, Ganged Distribution Outlet
C20 Socket acc to IEC 60320-1
70 °C pin Temperature
Rocker Switch Protected
Suitable for use in equipment according to IEC/UL 60950
OTHER SIZES CAN BE MADE TO ORDER
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 70 °C, 10A, Protection Class I
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Trent Part Number
DSTO-C20-6F-R-N-O-H (PDUC1306SH16AT)
Rated Voltage
250V
Rated Current
16A
No of Outlets
6
Operating Temperature
-25°C to 120°C
Filter Type
N/A
Overload Protection
YES
Line Switch
Rocker Switch - 16 Amp (red Illumination)
Mounting
Rear Mounted with Plastic Hooks
Material
Powder Coated Metal black
Termination Style
1 x C20 Inlet, 6 x F/C13 Outlet
Weight
2300g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV (L-N, L/N-E)
VDE/CE/ROHS
YES
Datasheet
Product Datasheet
Eastron Europe DCM230 1-2-1-1 V2, DIN Rail Mount DC kWh Meter, 1000VDC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved
45/60/75mV Shunt Connect
RS 485 communication up to 38,400 bit/s as standard
1 x Pulse Outputs (1 Configurable)
Bidirectional Measurement
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records DC Current and Voltage (DC Power) value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, energy, power) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
DCM230 1-2-1-1 V2
Functions
DC Energy Meter
Supply Voltage
9-60VDC
Nominal Measurement Range
5-300VDC,5-600VDC,5-1000VDC (See version 1
Maximum Measurement Range
5-1000VDC
Nominal Current Input
Shunt up to 2000Amp See our DC Current Shunt Section for Suitable Shunt
Pulse Output
1 x Configurable 60/100/200ms
Tariff Input
N/A
Accuracy
Class 1 (I,U,kW,kWh)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
36mm x 100mm x 66mm (2 modules wide)
Isolation
4kV
RS485
2400-38400 b/s
Weight
250g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Utility
EEM Meter Setting Software Utility
GO 4-SMS/SP3, O/L Hall Effect Current Sensor with evaluation PCB, 4 Amp
Features
Hall effect measuring principle
Galvanic separation between primary and secondary circuit
Insulated test voltage 3000 V RMS
Low power consumption
Extremely low profile
Single power supply +5 V
Double overcurrent detection
Fixed offset & sensitivity
Response time 2 µs.
Advantages
Small size and space saving
High immunity to external interference
High insulation capability Industrial.
Low electrical resistance (0.75 m?)
No magnetic hysteresis
Robust against external fields and cross-talk.
Applications
Appliances
Small drives
HVAC
Solar
E-Bikes
Standards
IEC 62109-1: 2010
IEC 60950-1: 2005
IEC 61800-5-1: 2007
UL 1577: 2014.
Application Domains
Industrial
Specification
LEM Part Number
GO 4-SMS/SP3
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
3.3 VDC
Load Current (RMS + DC)
4 Amp
Overload Capability
+/-200 Amp
Output
2.5 Vref
Isolation
2.5 kV
Bandwidth
DC-300 kHz
Mounting Style
Surface Mount - SOIC 8 Pin
Operating Temperature Range
-40°C / 125°C
Accuracy
2%
Termination Style
N/A
Unit Weight
10g
Factory Pack Quantity
150
Datasheet
Product Datasheet
Rishabh Xmer CT Split 155/80 3000/5 SCCT Class 0.5 20VA Series Split Core Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 155/80 3000/5 SCCT Class 0.5 20VA
Technology
Split Core AC Current Transformer
Ratio
3000/5
Aperture Size
85 x 125mm
VA Rating
20VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
3000Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet