E62.H85-303G1L, 30uF, 55x85mm Heavy Duty AC Film Power Capacitor w/Stud -40 to 85 °C 200,000 hrs, 680VAC/1120VDC, LeCLanche Part#OBIC 68-30.0 cv5
Characteristics and utility
30uF 680VAC/1120VDC
Metalized Polypropylene Film
Connector type - M6 x 12mm Studs
M12 Stud mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
E62.H85-303G1L (LeCLanche Part#OBIC 68-30.0 cv5)
Technology
Metalized Polypropylene Film Capacitor
Dimensions
ø55x85mm
Mounting
M12 Stud
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
680VAC/1120VDC
Operating Temperature Range
-40 to 85 °C
Capacitance
30uF
Tolerance On Capacitance
+10 / -10%
Lifetime
200,000 Hours @ 85 °C (Statistical Life)
Termination Style
Faston
Unit Weight
0.18kg
Factory Pack Quantity
21 (MOQ = 105)
Datasheet
Product Datasheet
Fastron Electronics FGC1-D6511-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole NO (1NO + 1NC), Nominal Current = 65 Amps(AC-3) @ 240/400/500/690V
Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
CE, CB Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Fastron Electronics Part Number
FGC1-D6511-230VAC
Functions
3 Pole Contactor
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
65 Amp Continuous @ 55 Deg C
Main Contacts
3 x NO
Aux Contacts
1NO + 1NC
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
4.6W
Approvals
CE, CB, TUV, LVD
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-DVO(-75mV,+75mV)D1, Signal Conditioner/Isolator/Voltage Transducer, +75mV to -75rmVDC input, 22-60VAC/DC aux, 4-20mA output
Program control, converter function are standard features
5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
9-step pattern (for SV and time) is a standard feature
UL/CSA Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
Specification
Fastron Electronics Part Number
GT-DVO(-75mV,+75mV)D1
Control Output
4 - 20mA
Input
+75mVDC to - 75mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM DHAB S/106, O/L Automotive AC/DC Current Transducer, Multirange +/-20A +/-500A, 5VDC Supply, 22.5mm Round Aperture
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-20A, and +/-500A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/106
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-20 Amp
Load Current Channel 2 (RMS)
+/-500 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 70Hz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.30%(10A),0.4%(20A)
CH2 Accuracy @ 25 Deg C
1.5%(0A),6%(250A),9%(500A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
Semikron SKD160/18, 3 Phase Diode Rectifier Bridge, 205Amp, 1600V, Replaces Powersem PSD162T/16, and IXYS VUO160-16 N07
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Semikron Part Number
SKD160/18
AC Line voltage
1800V
Device Configuration
Three Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
160 Amp
Package Size
W:94mm L:54mm D:30mm
Itsm
1800 A
VF(to)
0.8V
Tj(max)
150°C
Terminals
M6 (5Nm)
Hole Centres
80mm (M6)
Gate Terminals
N/A
Weight
270g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
Semikron Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See PSD192T/16 for higher rated equivalent
DC-0-50-420-1.0, Hall Effect DC Current Transducer, 0-50 Amp DC, 4-20mA Unipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-50 Amp DC, 4-20 mA Unipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-50-420-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-50 Amp
Response Time
< 1uS
Output
Unipolar 4-20mA
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-100-1-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-100 Amp DC, +/-10VDC Bipolar or 0-10V Bipolar Analogue Output
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 0-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-100-2-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/100 Amp DC, 4-20mA Bipolar Output
Features
⌀31mm Aperture
DC Bipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
F19-271YF19-271Y-L, 19mm Pushbutton Switch Metal with YELLOW Ring Illumination, 1xNO 1xNC, 3 Amp (Nominal) 5 Amp (Max) @ 250VAC or 24VDC, 24VDC Illumination Supply, 0.05 Million Ops
Description
Pushbutton switch available in version Standard, Illuminated, with Point Illumination, 1xNO 1xNC, Lettering, varnished in different colours
Assembly by mounting with nut
Pin connections, Pins with Soldering Aid or Clip for Pins
Characteristics
Housing and actuator material types: zinc die-cast with nickel plating or stainless steel
Wide range of materials, colours, lettering, colours of illumination - Switching voltage max. 250VAC 30VDC, switching current max. 12 Amp
24VDC Illumination Supply Voltage
Zinc die-cast for housing and actuator For indoor use, no Illumination, 1xNO 1xNC, no lettering
Stainless Steel for actuator Optional point illumination and laser lettering with standard or customer-specific symbols
Stainless Steel for housing and actuator for use in harsh environments outdoors (see technical data)
Tamper Proof suitable for public spaces
Specification
Fastron Electronics Part Number
F19-271Y
Switch Size
20 x 19mm
Nominal Voltage
250VAC/DC
Rated Power
750W
Switch Type
Momentary1NO + 1NC
Illumination voltage
24VDC @ 10mA
Illumination type
YELLOW RING
Nominal Current (AC/DC)
3 Amp @240VAC/24VDC
Contact Resistance ON/OFF
<100m Ohm
Dimensions
ø22 x 14.6mm
Operating Temperature Range
-20°C / 85°C
Termination
Faston/Solder Pins
IP Protection Rating
(IP 67 with Oring) IP 64 (IP40 switching circuit)
Unit Weight
40g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fastron FRTD-8-247-3-12-5000PVC, Class A 247 x 8mm Probe, 12 x 3mm Tip, 304 Stainless Steel w/ 5000mm PVC Tails, -50 to 100 Deg C
Class A Accuracy
Teflon/Screen/Teflon Cable
Low Long Term Drift
Rated for -50 to 200 Deg C Max
Spring Cable Connection
6 x 150mm
MIMS
Recommended to use BSP Fitting for mounting
Specification
Fastron Part Number
FRTD-8-247-3-12-5000PVC
Sensor Type
RTD Pt100 Thermocouple
No of Wires
3
Material
304 Stainless Steel
Shaft Length
247mm (12mm Tip)
Shaft Thickness
8mm (3mm Tip)
Approvals
CE, ANSI, ROHS
Accuracy
Class A
Cable length
5 Meter
Cable Type
Teflon/Screen/Teflon
Temperature Range
-50 to 200 Deg C
Special Feature
High Temperature Epoxy Sealed
Mounting Style
Loose (BSP Fitting recommended)
Weight
500g
Factory Pack Qty
1
Datasheet
Product Datasheet
Magnelab SCT-0400-050, 50 Amp, 0.333v Class 1 Series Current Transformer, 10mm Aperture, UL approved
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Magnelab Part Number
SCT-0400-050
Technology
Split Core AC Current Transformer
Ratio
50/0.333v
Aperture Size
ø 10 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
50Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
GO 4-SMS/SP3, O/L Hall Effect Current Sensor with evaluation PCB, 4 Amp
Features
Hall effect measuring principle
Galvanic separation between primary and secondary circuit
Insulated test voltage 3000 V RMS
Low power consumption
Extremely low profile
Single power supply +5 V
Double overcurrent detection
Fixed offset & sensitivity
Response time 2 µs.
Advantages
Small size and space saving
High immunity to external interference
High insulation capability Industrial.
Low electrical resistance (0.75 m?)
No magnetic hysteresis
Robust against external fields and cross-talk.
Applications
Appliances
Small drives
HVAC
Solar
E-Bikes
Standards
IEC 62109-1: 2010
IEC 60950-1: 2005
IEC 61800-5-1: 2007
UL 1577: 2014.
Application Domains
Industrial
Specification
LEM Part Number
GO 4-SMS/SP3
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
3.3 VDC
Load Current (RMS + DC)
4 Amp
Overload Capability
+/-200 Amp
Output
2.5 Vref
Isolation
2.5 kV
Bandwidth
DC-300 kHz
Mounting Style
Surface Mount - SOIC 8 Pin
Operating Temperature Range
-40°C / 125°C
Accuracy
2%
Termination Style
N/A
Unit Weight
10g
Factory Pack Quantity
150
Datasheet
Product Datasheet